Open the catalog to page 1CC613 charge controller Charge controller for use in electric vehicle charging stations, wallboxes or street light charging points Device features (depending on the variant) • Charge controller in accordance with IEC 61851-1 (charging mode 3) • Configurable master and slave operation Setting up charging stations with two charging points: - 1 charge controller as data gateway with 4G modem - 1 charge controller as slave without 4G modem • Dynamic load management to optimally distribute the available power among all charging points and signal the maximum power available in each case to the vehicle...
Open the catalog to page 2The charging system consists of an RCD type A and a contactor. These are directly connected to a type 1 or type 2 socket-outlet, or to a permanently mounted cable with a type 1 or type 2 plug (see "Wiring diagram"). • The charging system can be equipped with a meter. A Modbus meter is required to digitally read the energy consumption. The Modbus RTU lines are attached directly to the device. • A 12 V power supply is needed for operation. • An RFID module can be used for easy user interaction. • Current low toward the vehicle is released by enabling the contactor via an integrated 230 V control...
Open the catalog to page 3CC613 charge controller Z BENDER Charging system with type 2 socket-outlet Terminal assignment CAUTION! Switching contact contactor and weld check at terminal H are only suitable for mains voltage (230 V)! Not permitted for SELV/PELV voltages.
Open the catalog to page 4Technical data Overvoltage category within terminal H II Overvoltage category, terminal H and all other terminals III Rated impulse voltage, terminal H and all other terminals 6 kV Rated impulse voltage within terminal H 2.5 kV Double insulation between terminal H and all other terminals OCV III Basic insulation within terminal H OCV II Operating altitude AMSL < 2000 m Supply voltage (terminal B (0CV, +12CV)) Operating range of the nominal voltage DC 11.4...12.6 V Max. nominal current without USB load 400 mA Max. nominal current with USB load 750 mA Weld check (terminal H (WB, WA)) Outputs (depending...
Open the catalog to page 5Ordering information 2) The PCB-variant can be combined with the connection cables of different lengths. E& BENDER The Power in Electrical Safety0 Londorfer StraBe 65 • 35305 GrGnberg • Germany Tel.: +49 6401 807-0 • [email protected] • www.bender.de
Open the catalog to page 64 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
12 Pages
10 Pages
10 Pages
6 Pages
6 Pages
12 Pages
12 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
8 Pages
8 Pages
6 Pages
8 Pages
8 Pages
8 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
8 Pages
4 Pages
10 Pages
6 Pages
6 Pages
6 Pages
12 Pages
8 Pages
4 Pages
4 Pages
4 Pages
4 Pages
7 Pages
8 Pages
12 Pages
10 Pages
8 Pages
6 Pages
10 Pages
6 Pages
6 Pages
6 Pages
10 Pages
8 Pages
6 Pages
6 Pages
6 Pages
8 Pages
6 Pages
6 Pages
6 Pages
6 Pages
8 Pages
6 Pages
12 Pages
12 Pages
12 Pages
4 Pages
7 Pages
7 Pages
2 Pages
6 Pages
6 Pages
6 Pages
6 Pages
6 Pages
6 Pages
4 Pages
8 Pages
12 Pages
14 Pages
10 Pages
4 Pages
14 Pages
6 Pages
16 Pages
6 Pages
8 Pages
6 Pages
4 Pages
8 Pages
4 Pages
8 Pages
8 Pages
10 Pages
8 Pages
8 Pages
6 Pages
8 Pages
6 Pages
4 Pages
6 Pages
6 Pages
10 Pages
8 Pages
8 Pages
6 Pages
6 Pages
8 Pages
6 Pages
10 Pages
6 Pages
6 Pages
2 Pages
6 Pages
10 Pages
10 Pages
10 Pages
8 Pages
8 Pages
4 Pages
12 Pages
8 Pages
10 Pages
10 Pages
12 Pages
4 Pages
12 Pages
14 Pages
12 Pages
16 Pages
6 Pages
14 Pages
10 Pages
486 Pages