Device Features
ATICS-2-63A-ISO and ATICS-2-80A-ISO are compact automatic transfer switching devices designed for unearthed safety power supplies, particularly suitable for medical locations. They integrate changeover and IT system monitoring, enhancing safety and availability. The devices are certified for functional safety SIL 2 by TÜV SÜD.

Installation and Operation
The devices are designed for easy installation and commissioning, saving time and money. They feature robust switch disconnector contacts, mechanical locking, and manual operation capabilities. Uninterrupted maintenance is facilitated by plug connectors and optional bypass switches.

Product Description
These devices provide automatic changeover between two power supplies and monitor unearthed power supplies. They reduce space requirements and wiring complexity, enhancing reliability. They are particularly beneficial in intensive care units and operating theatres.

Changeover and Monitoring Functions
The devices automatically switch to a redundant line if the preferred supply fails or voltage is outside permissible ranges. They monitor voltage, short circuits, and allow manual operation with optional locking. Insulation, load, and temperature monitoring are included for IT systems.

Technical Data
The devices operate at a supply voltage of 230 V with power consumption varying by model. They support a frequency range of 48-62 Hz and have a mechanical switching cycle life of over 8000 cycles. Insulation monitoring and load current monitoring are key features, with detailed specifications provided for each.

Standards and Certifications
The devices conform to various standards, including DIN VDE 0100-710 and IEC 61508, ensuring compliance with safety and performance requirements.

Ordering Information
Various models and optional accessories are available, including measuring current transformers and bypass switch sets. Detailed ordering information and part numbers are provided.

Conclusion
ATICS-2-63A-ISO and ATICS-2-80A-ISO devices offer a comprehensive solution for managing and monitoring unearthed safety power supplies, particularly in critical medical environments, ensuring high safety and reliability standards.
See more

Catalog excerpts

ATICS-2-63A-ISO / ATICS-2-80A-ISO-1

ATICS-2-63A-ISO / ATICS-2-80A-ISO Automatic transfer switching devices with monitoring functions for unearthed safety power supplies

 Open the catalog to page 1
ATICS-2-63A-ISO / ATICS-2-80A-ISO-2

ATICS-2-63A-ISO / ATICS-2-80A-ISO Automatic transfer switching devices with monitoring functions for unearthed safety power supplies Device features Perfectly suitable for space-saving • Compact device for easy setup of safety power supplies with functional safety in accordance with DIN EN 61508 (SIL 2) e. g. for group 2 medical locations • Increased safety and availability by integrating changeover and IT system monitoring in one compact device • All-in-one: Integration of switch disconnector, control and monitoring electronics for unearthed safety power supplies • Saves time and money Safe...

 Open the catalog to page 2
ATICS-2-63A-ISO / ATICS-2-80A-ISO-4

supply line supply line Nurse desk Intensive care unit ATICS-2-63A-ISO

 Open the catalog to page 4
ATICS-2-63A-ISO / ATICS-2-80A-ISO-5

Insulation coordination acc. to IEC 60664-1/IEC 60664-3 Overvoltage category III Pollution degree outside, inside 2 Rated insulation voltage 250 V Protective separation between Line 1 - Line 2; Line 1,2, 3 - RS-485; Line 1,2, 3 - digital inputs; Line 1, 2, 3 - relay outputs Voltage test according to IEC 61010-1 2.21 kV / 3.54 kV (basic insulation/protective separation) Supply voltage Supply voltage Us Power consumption at 63 A Power consumption at 80 A Current during changeover process Nominal system voltage Un (operating range) Measuring range Measurement method Response value (ALARM 1) Relative...

 Open the catalog to page 5
ATICS-2-63A-ISO / ATICS-2-80A-ISO-6

Displays and data memory Display: graphic display Alarm LEDs History memory Data logger Config. logger Test logger Service logger languages DE, EN, FR, PL Line 1, Line 2, Alarm, Com 500 data records 500 data records/channel 300 data records 100 data records 100 data records Classification of mechanical conditions acc. to IEC 60721 Power section Digital inputs Galvanic separation Control Operating mode Voltage range high/low Adjustable function via potential-free contacts active at 0 V (low) or 24 V (high), adjustable AC/DC 10.. .30 V / AC/DC 0.. .0.5 V switch-back lock, manual/automatic mode,...

 Open the catalog to page 6
ATICS-2-63A-ISO / ATICS-2-80A-ISO-7

The transfer switching and monitoring device conforms to the following standards: Standard-compliant isolating transformer monitoring according to: The standards marked with * were part of the test conducted by TUV Sud. The EU Declaration of Conformity is available at the following Internet address:

 Open the catalog to page 7
ATICS-2-63A-ISO / ATICS-2-80A-ISO-8

Ordering information ATICS®-...-DIO Variants Description ATICS-2-...-ISO: 2-pole transfer switching and monitoring device with integrated insulation, load and temperature monitoring of the IT system, 1 dig. input, 1 relay output, short-circuit detection in TN systems, with sealable contact covers on the input and output sides, bridges on the output side and pluggable screw-type terminals for all connections. Measuring current transformers STW2 and STW3. © Bender GmbH & Co. KG, Germany Subject to change! The specified standards take into account the edition valid until 02.2025 unless otherwise...

 Open the catalog to page 8

All BENDER GmbH & Co KG catalogs and technical brochures

  1. CD25000

    4  Pages

  2. CD14400

    4  Pages

  3. CD1000

    4  Pages

  4. AUR381Z

    4  Pages

  5. AN110

    4  Pages

  6. AGH575S-6

    4  Pages

  7. CD1000-2

    4  Pages

  8. MRCDB300 series

    12  Pages

  9. AN111

    4  Pages

  10. AN450

    4  Pages

  11. AN420

    4  Pages

  12. AN410

    4  Pages

  13. STEP-PS

    8  Pages

  14. CTBC17 series

    8  Pages

  15. IPM1300

    8  Pages

  16. CC613

    6  Pages

  17. ICC1324

    8  Pages

  18. ICC1314

    8  Pages

  19. AGH676S-4

    4  Pages

  20. AGH520S

    4  Pages

  21. AGH204S-4

    4  Pages

  22. AGH150xx

    4  Pages

  23. AT series

    6  Pages

  24. DI-1DL

    4  Pages

  25. SMO482P-12

    4  Pages

  26. DI-2USB

    4  Pages

  27. POWERSCOUT®

    8  Pages

  28. SEB30, SEB60

    8  Pages

  29. VIT-AFSBY

    6  Pages

  30. VIT-A

    6  Pages

  31. RDC125-5S

    12  Pages

  32. RCMB131-01

    4  Pages

  33. RDC121

    7  Pages

  34. RCMB123

    7  Pages

  35. RDC104-4

    6  Pages

  36. RCMB104

    6  Pages

  37. RCMB300-series

    12  Pages

  38. Energy meter

    6  Pages

  39. PEM353

    8  Pages

  40. DS0107

    6  Pages

  41. ESL0107

    4  Pages

  42. ES710

    8  Pages

  43. AGH520S

    4  Pages

  44. RCM410R

    8  Pages

  45. RCMS410

    10  Pages

  46. RCMS425-D

    10  Pages

  47. EDGE500

    12  Pages

  48. Iso415R

    4  Pages

  49. Iso685-x-B

    12  Pages

  50. Iso685-x-P

    14  Pages

  51. Iso685-x

    12  Pages

  52. Data Centers

    16  Pages

  53. RCMB104

    6  Pages

  54. Main Catalogue

    486  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.