AGH675S-7/AGH675S-7MV15 series-2

Coupling devices AGH675S-7/AGH675S-7MV15 series Product description The coupling devices of the AGH675S-7/AGH675S-7MV15 series are used to extend the nominal voltage range of the ISOMETER® IRDH275BM-7 illustrated in the wiring diagram. The ISOMETER® IRDH275BM-7 together with the coupling device AGH675S-7 monitors the insulation resistance of IT medium voltage systems up to 7,2 kV. The ISOMETER® IRDH275BM-7 together with two coupling devices AGH675S-7MV15 monitors the insulation resistance of IT systems up to 15,5 kV. Always two AGH675S-7MV15 together with one IRDH275BM-7 are required. Terminal...

 Open the catalog to page 2
AGH675S-7/AGH675S-7MV15 series-3

Coupling devices of the AGH675S-7/AGH675S-7MV15 series Wiring diagram AGH675S-7 (example) Wiring diagram AGH675S-7MV15 (example) DC 15.5 kV The terminals "AK" of the two coupling devices AKs are bridged and connected to terminal AK of the IRDH275BM-7. Dimension diagram Dimensions in mm 220 200 178

 Open the catalog to page 3
AGH675S-7/AGH675S-7MV15 series-4

Technical data Rated insulation voltage AGH675S-7MV15 Rated insulation voltage Voltage test according to IEC 61800-5-1 Type test: AC voltage test (basic insulation) AC voltage test (basic insulation) Partial discharge test Impulse voltage test (basic insulation) AC voltage test (basic insulation) Partial discharge test Routine test: Voltage ranges Nominal system voltage Un Nominal frequency fn Internal DC resistance R AGH675S-7MV15 Nominal system voltage Un Nominal frequency fn Internal DC resistance R Operating temperature (normal operation) - 10...+ 60 °C AC 7 2 kV Operating temperature (continuous...

 Open the catalog to page 4

All BENDER GmbH & Co KG catalogs and technical brochures

  1. CD25000

    4  Pages

  2. CD14400

    4  Pages

  3. CD1000

    4  Pages

  4. AUR381Z

    4  Pages

  5. AN110

    4  Pages

  6. AGH575S-6

    4  Pages

  7. CD1000-2

    4  Pages

  8. MRCDB300 series

    12  Pages

  9. AN111

    4  Pages

  10. AN450

    4  Pages

  11. AN420

    4  Pages

  12. AN410

    4  Pages

  13. STEP-PS

    8  Pages

  14. CTBC17 series

    8  Pages

  15. IPM1300

    8  Pages

  16. CC613

    6  Pages

  17. ICC1324

    8  Pages

  18. ICC1314

    8  Pages

  19. AGH676S-4

    4  Pages

  20. AGH520S

    4  Pages

  21. AGH204S-4

    4  Pages

  22. AGH150xx

    4  Pages

  23. AT series

    6  Pages

  24. DI-1DL

    4  Pages

  25. SMO482P-12

    4  Pages

  26. DI-2USB

    4  Pages

  27. POWERSCOUT®

    8  Pages

  28. SEB30, SEB60

    8  Pages

  29. VIT-AFSBY

    6  Pages

  30. VIT-A

    6  Pages

  31. RDC125-5S

    12  Pages

  32. RCMB131-01

    4  Pages

  33. RDC121

    7  Pages

  34. RCMB123

    7  Pages

  35. RDC104-4

    6  Pages

  36. RCMB104

    6  Pages

  37. RCMB300-series

    12  Pages

  38. Energy meter

    6  Pages

  39. PEM353

    8  Pages

  40. DS0107

    6  Pages

  41. ESL0107

    4  Pages

  42. ES710

    8  Pages

  43. AGH520S

    4  Pages

  44. RCM410R

    8  Pages

  45. RCMS410

    10  Pages

  46. RCMS425-D

    10  Pages

  47. EDGE500

    12  Pages

  48. Iso415R

    4  Pages

  49. Iso685-x-B

    12  Pages

  50. Iso685-x-P

    14  Pages

  51. Iso685-x

    12  Pages

  52. Data Centers

    16  Pages

  53. RCMB104

    6  Pages

  54. Main Catalogue

    486  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.