EQUIPMENT Voltage adjustment trimmer; Stability control trimmer; V/Hz threshold sitting trimmer; Protection against over voltage; Minimum self-excitation voltage: 2 Volt; Protection against Maximum excitation at low revolutions (adjustable setting from 40+50 or 50+60) used in the pre-heater of the diesel engine or hydroelectric plants; Wire jumper (1) for the possible connection to a potentiometer of 1000Q - 'A Watt for remote voltage setting (variation range 10%); Wire jumper (3) for frequency selection 50 or 60Hz; Wire jumper (2) (red) for operation at 115 V; USER AND INSTALLATION MANUAL PERFORMANCES The...
Open the catalog to page 3INSTALLATION AND ASSEMBLY The regulator must be installed inside the machine or inside the control and command panel, in order to be protected against accidental contacts. Its installation should be done in an easily and accessible place with a clean and dry air exchange in recommended. Use the two holes on the corners and 4MA screws to secure the machine. ACCEPTANCE Regulators are normally supplied with standard packaging. With a small extra charge and upon customer request, a special packaging can be provided (for sea shipping, airfreight, etc). At the receipt of the package, check the AVR conditions...