S2006 - 1

Automatic voltage regulators mod. S2006 Automatic voltage regulators for Brusheless alternators for hydroelectric thermoelectric and diesel power stations (500 KW -150 MW). S2006 is the new model of digital controller manufactured by BELTRAME CSE. It controls alternators excitation and its easy programming software makes it suitable for a wide range of alternators. It also enables a big flexibility on parameters optimization. FEATURES Functions • Five control modes: o Manual mode o Automatic Voltage Regulation (AVR) o Automatic Current Regulation (FCR) o Power Factor Regulation (PF) o Reactive power regulation (VAR) • In AVR and FCR modes the voltage regulation is made by “softstart” ramp • Wide range of regulations and “set points” for each functioning mode • Protection for over excitation (OEL) and under excitation (UEL) when working in AVR, VAR and PF modes • Compensation for under-frequency or limitation of the tension/ frequency ratio [V/Hz] • Parallel managing with Main or with other AVR S2006 • Eight generator protection functions: o Protection from excitation over-voltage o Protection from excitation over-current o Protection from generator over-voltage o Protection from generator under-voltage o Surveying timer o Lack of sensing o Excitation diodes controlling device (optional) o Lack of field voltage • Generators parallel connection with “droop” reactive compensation and differential reactive compensation and remote control to the regulating point • Eleven digital inputs for the interface with the PLC • Redundant AC/DC power supply • Power output up to a maximum of 25A in continuous duty and positive ceiling voltage of 40 • Ten exit relays for controlling the system or for warning Inputs and Outputs • Single-phase or three-phase rms bus voltage sensing (60÷480V ac/dc 40÷500Hz) • Single phase or three phases rms generator voltage sensing 100÷500V ac) • Single phase generator current (nominal 1A or 5A) • Analog inputs (±10 Vdc and 4÷20 mAdc) providing a proportional APPLICATIONS In the typical application described hereinafter, the AVR S2006 controls the excitation field of a synchronous generator. The front control panel, the indicators and the serial communication ports using the PC software, ease the on-site/remote use of the system. HMI Interface • The HMI front panel includes control buttons and LED indicators • Five communication ports: o RS-232 port, for PC communication o CANBUS port for specific communication with a redundant AVR S2006 o RS-485 communication port o USB communication port o Ethernet communication port Technical Features Maximum output current in continuous duty: 25A Maximum output current per 10 sec. : 40A Auxiliry input frequency range: 50Hz ÷ 500Hz Alternator nominal frequency: 50Hz or 60Hz Temperature range in duty: 0°C ÷ +55°C Temperature range in stock : -20°C ÷ 80°C Dimensions (mm): wide 300 mm, length 400 mm height 115 mm Thirty years of cutting-edge technology and support in ENERGY MANAGEMENT

Open the catalog to page 1
S2006 - 2

SISTEMI E APPARECCHIATURE PER IL CONTROLLO E LA GESTIONE DELL'ENERGIA PER SMART GRID, ECCITATRICI STATICHE, REGOLATORI Dl TENSIONE DIGITALI, REGOLATORI Dl GIRI DIGITALI, ENERGIE ALTERNATIVE, Beltrame CSE has designed and produced Regulation systems for over thirty years. Our technical expertise is guaranteed by the application of the ISO 9001 standard. We offer products and services ensuring regulation safety during the generation of electric power. Customised service, fast delivery, competitive prices and careful client needs assessment have earned us a reputation. We are now one of the...

Open the catalog to page 2

All BELTRAME CSE catalogs and technical brochures

  1. S2007

    2 Pages

  2. S2006

    3 Pages

  3. S2022

    4 Pages

  4. S155

    4 Pages

  5. S130

    4 Pages

  6. S099

    2 Pages

  7. S130 10A

    4 Pages

  8. S2016

    4 Pages

  9. S125

    4 Pages

  10. S2013

    4 Pages

  11. DG5

    4 Pages

  12. BM42E

    2 Pages

  13. BM60M

    2 Pages

  14. LPW2

    4 Pages

  15. DG4

    4 Pages

  16. DG164

    4 Pages

  17. DG 184

    4 Pages

  18. ARC2005

    5 Pages

  19. ARC2000

    10 Pages

  20. DG6

    4 Pages

  21. DG182

    4 Pages

  22. DG162

    4 Pages

  23. DMW5E

    2 Pages

  24. S2004

    7 Pages

  25. AVR S160

    2 Pages

  26. AVR S155

    2 Pages

  27. AVR S130-10A

    2 Pages

  28. AVR S130-25A

    2 Pages

  29. AVR S125

    2 Pages