DIGITAL SPEED CONTROL FOR TURBINES
7Pages

{{requestButtons}}

Catalog excerpts

DIGITAL SPEED CONTROL FOR TURBINES - 1

Beltrame C.S.E., via S. Pio X 104, 35015 Galliera Veneta, Padova, Italy. Phone: +39 049 5965127; Fax: +39 049 9440024; Web site: www.beltramecse.com; e-mail: info@beltramecse.com ARC® family S2005 Digital speed control for turbines ·

Open the catalog to page 1
DIGITAL SPEED CONTROL FOR TURBINES - 2

- 2 - · Speed governor · Measuring: active power, reactive power and other data. · Dynamic changes during functioning · Configurable on site · Digital controller DSP · Synchronizer · PF or VAR adjustment INTRODUCTION Thanks to the strengthened experience BELTRAME C.S.E. has acquired in the field of energy management, a new model of the turbine speed governor, family S2005, is now available. The control, which is based on a micro-controller with core DSP and acquisition of the analogic data at 12 bit, implements the most sophisticated technologies provided by the nowadays electronic and...

Open the catalog to page 2
DIGITAL SPEED CONTROL FOR TURBINES - 3

- 3 - AVAILABLE OUTPUTS · 6 analogic and configurable outputs (hardware and in-between insulated) · 1 analogic output for AVR. · 1 actuator output 1. · 1 actuator output 2. · 13 digital outputs. COMMUNICATIONS · Serial for programming type RS232. · Serial for the communication with the operator panel type RS485. · Ethernet interface for web connection. FUNCTIONALITY · Speed governor. · Turbine load control (power loop). · Measuring of electric parameters. · Synchronization. · PF or VAR regulation. OPERATOR PANEL (optional) The operator panel allows an easy and simple visualization in real...

Open the catalog to page 3
DIGITAL SPEED CONTROL FOR TURBINES - 4

- 4 - CURVE OF TURBINE HEATING Once started, the regulator follows the heating curve here below indicated. Greater would be the pause time and higher would be the time needed for the new start. The waiting time, the ramps and the steps values are settable from set-up. Heating curve when hot within 2 hours from stopping Heating curve when cold 24 hours after stopping Time in minutes Rev olutions

Open the catalog to page 4
DIGITAL SPEED CONTROL FOR TURBINES - 6

- 6 - Test inputs / outputs Parameter programming

Open the catalog to page 6
DIGITAL SPEED CONTROL FOR TURBINES - 7

- 7 - Visualization of parameters progress (exciters and speed governor) Control Panel

Open the catalog to page 7

All BELTRAME CSE catalogs and technical brochures

  1. S2007

    2 Pages

  2. S2006

    3 Pages

  3. S2022

    4 Pages

  4. S155

    4 Pages

  5. S130

    4 Pages

  6. S099

    2 Pages

  7. S130 10A

    4 Pages

  8. S2016

    4 Pages

  9. S125

    4 Pages

  10. S2013

    4 Pages

  11. DG5

    4 Pages

  12. BM42E

    2 Pages

  13. BM60M

    2 Pages

  14. LPW2

    4 Pages

  15. DG4

    4 Pages

  16. DG164

    4 Pages

  17. DG 184

    4 Pages

  18. ARC2005

    5 Pages

  19. ARC2000

    10 Pages

  20. DG6

    4 Pages

  21. DG182

    4 Pages

  22. DG162

    4 Pages

  23. DMW5E

    2 Pages

  24. S2004

    7 Pages

  25. AVR S160

    2 Pages

  26. AVR S155

    2 Pages

  27. AVR S130-10A

    2 Pages

  28. AVR S130-25A

    2 Pages

  29. AVR S125

    2 Pages

Archived catalogs

  1. S2006

    2 Pages