DG6

DG6

DG6

Product catalog summary
General Overview: The DG6 series alternators cover a range from 5kVA to 1386kVA, suitable for industrial, marine, commercial, construction, mining, and telecommunications applications. They are designed for both prime and standby power generation.
Specifications: The alternators are available in single and double-bearing constructions, with international SAE flange adaptors and disc couplings. They comply with standards such as IEC60034-1/60034-2, BS4990 & 5000, VDE0530, NEMA MG1-2006, and CSA C/UL. They are ISO 2000 and CE certified.
Mechanical Features: Single-bearing alternators ensure alignment during assembly, while double-bearing alternators are balanced with a 1/2 key and can operate in both clockwise and counterclockwise directions.
Electrical Features: The alternators allow for overloads of up to 50% for 2 minutes and can sustain 300% short circuit current for 10 seconds with an optional Permanent Magnet. They permit an unbalanced load of 25% rated current with minimal voltage deviation.
Insulation and Performance: The insulation system is class 'H' with vacuum pressure impregnation. The stator is wound to 2/3 pitch to eliminate harmonics, ensuring a stable supply for non-linear loads. TIF is better than 2% as per BS4999 Part 40.
Interference and Damping: The alternators have interference suppression grade N to VDE 0875 and excellent damping against torsional vibrations.
Accessories and Options: Available options include a droop kit, remote voltage potentiometer, PT100 thermal protection, anti-condensation heaters, IP23 protection, and special treatments for harsh environments.
Environmental Considerations: All ratings are based on a 40°C ambient temperature at 1000m altitude. Performance decreases with higher altitudes and lower power factors.
See more

Catalog excerpts

DG6-2

3 Phase H insulation Industrial Voltage Series Star Parallel Star Series Delta 3 Phase F insulation Marine Voltage Series Star Parallel Star Series Delta

 Open the catalog to page 2
DG6-3

SINGLE BEARING DIMENSIONS DOUBLE BEARING DIMENSIONS DISC CONPLING DISC CONPLING FLANGE ADAPTOR FLANGE ADAPTOR SINGLE BEARING SHIPPING DETAILS DOUBLE BEARING SHIPPING DETAILS

 Open the catalog to page 3
DG6-4

DESCRIPTION OF MAIN CHARACTERISTIC GENERAL Alternator full range covers ratings from 5kVA to 1386kVA, so meeting the most part of needs for industrial, marine, commercial, construction, mining and telecommunications, both for prime or standby power generation. ALTERNATOR CONSTRUCTURE Ac generators are self-excited, self-regulated, and supplied with regulator and inbuilt booster. COMPLIANCE WITH STANDARDS The generators are designed in compliance with IEC60034-1/60034-2, BS4990 & 5000, VDE0530, NEMA MG1-2006, CSA C/UL. Certificate ISO 2000,CE conform to the requirements of IEC60034, certificate...

 Open the catalog to page 4

All BELTRAME CSE catalogs and technical brochures

  1. S155

    4  Pages

  2. S099

    2  Pages

  3. S130 10A

    4  Pages

  4. S2016

    4  Pages

  5. S130

    4  Pages

  6. S125

    4  Pages

  7. S2013

    4  Pages

  8. S2007

    2  Pages

  9. S2022

    4  Pages

  10. BM6.0M/BM6.0E

    2  Pages

  11. DG5

    4  Pages

  12. BM42E

    2  Pages

  13. BM60M

    2  Pages

  14. LPW2

    4  Pages

  15. DG164

    4  Pages

  16. DG4

    4  Pages

  17. DG 184

    4  Pages

  18. ARC2005

    5  Pages

  19. ARC2000

    10  Pages

  20. DG182

    4  Pages

  21. DG162

    4  Pages

  22. DMW5E

    2  Pages

  23. S2004

    7  Pages

  24. AVR S160

    2  Pages

  25. AVR S155

    2  Pages

  26. AVR S130-10A

    2  Pages

  27. AVR S130-25A

    2  Pages

  28. AVR S125

    2  Pages

Archived catalogs

  1. S2006

    3  Pages

  2. S2006_2012

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.