Technical data sheet CM230G-.. Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations • For air dampers up to approx. 0.4 m2 • Torque 2 Nm • Nominal voltage AC 100 ... 240 V • Control: Open-close or 3-point • Degree of protection IP66 Type overview Type Direction of rotation CM230G-L counter-clockwise (ccw) CM230G-R clockwise (cw) . . . . . . . . . . . Technical data Electrical data Functional data Nominal voltage Nominal voltage range Power consumption In operation At rest For wire sizing Connection AC 100 ... 240 V, 50/60 Hz AC 85 ... 265 V 1.5 W @ nominal torque 1W 3 VA Cable 1 m, 3 x 0.75 mm2 Torque (nominal torque) Direction of rotation Manual override Angle of rotation Without limit With limit Min. 2 Nm @ nominal voltage See «Type overview» Gear disengagement with magnet Endless Fixed 315° or 0 ... 287.5° with mechanical end stops, can be adjusted in 2.5° increments 75 s / 90° Max. 35 dB (A) Mechanical, pluggable (with integrated magnet for gear disengagement) Running time Sound power level Position indicator Safety Mode of operation Rated impulse voltage Control pollution degree Ambient temperature Non-operating temperature Ambient humidity Maintenance Notes • To guarantee IP66 protection, the device must be mounted on the rear of the damper housing without a gap. • If the device is mounted on the front of the damper housing (i.e. turned 180° ), it only has IP54 protection. Dimensions / Weight Protection class Degree of protection II totally insulated IP66 NEMA2, UL Enclosure Type 2 CE according to 2004/108/EC CE according to 2006/95/EC cULus according to UL 60730-1A and UL 60730-2-14 and CAN/CSA E60730-1:02 Certified to IEC/EN 60730-1 and IEC/EN 60730-2-14 Type 1 (EN 60730-1) 2.5 kV (EN 60730-1) 3 (EN 60730-1) –30 ... +50°C –40 ... +80°C 95% r.H., non-condensating (EN 60730-1) Maintenance-free Dimensions Weight See «Dimensions» on page 2 Approx. 220 g EMC Low voltage directive Certification Safety notes ! www.belimo.com • The actuator is not allowed to be used outside the specified field of application, especially in aircraft or any other form of air transport. • Caution: Power supply voltage ! • Assembly must be carried out by trained personnel. Any legal regulations or regulations issued by authorities must be observed during assembly. • The device may only be opened at the manufacturer‘s site. It does not contain any parts that can be replaced or repaired by the user. T2-CM230G-.. • en • v1.1 • 08.2008 • Subject to changes /2
Open the catalog to page 1CM230G-.. Damper actuator, AC 100 ... 240 V, 2 Nm, IP66 Safety notes (Continue) • When calculating the required torque, the specifications supplied by the damper manufactur ers (cross section, design, installation site), and the air flow conditions must be observed. • The device contains electrical and electronic components and is not allowed to be disposed of as household refuse. All locally valid regulations and requirements must be observed. Product features Simple direct mounting Simple direct mounting on the damper spindle with a universal spindle clamp (∅ 6 ... 12.7 mm). The actuator is...
Open the catalog to page 220 Pages
8 Pages
4 Pages
2 Pages
2 Pages
20 Pages
16 Pages
35 Pages
28 Pages
8 Pages