1. Catalogs
  2. Belgicast
  3. METEOR WIDE TOLERANCE FLANGE ADAPTOR

METEOR WIDE TOLERANCE FLANGE ADAPTOR

METEOR WIDE TOLERANCE FLANGE ADAPTOR

METEOR WIDE TOLERANCE FLANGE ADAPTOR

Product catalog summary
Specifications:
The Meteor Wide Tolerance Flange Adaptor is designed to accommodate a wide range of pipe diameters with an average tolerance of 25mm. It ensures reliability through guaranteed leak-tightness by compressing the gasket between the end rings and the sleeve onto the pipe. The adaptor is protected against corrosion with an epoxy powder coating of at least 250µm and uses stainless steel nuts and bolts.

Installation and Features:
The adaptor allows for easy and fast installation with an angular deflection of ±6°, compensating for pipe misalignment and absorbing pipe expansion and contraction. It is suitable for a range of nominal diameters from DN40 to DN300, with larger sizes available upon request. The maximum working pressure is PFA16, and it operates within a temperature range of 0°C to 60°C. The installation torque required is 40 N m.

Conformity and Approvals:
The product conforms to several standards, including EN14525, NF A 48-830, EN545, and ISO2531. It has received approvals such as ACS, WRAS, KIWA, and KTW W270 for its gasket and coating.

Applications:
The flange adaptor is suitable for use in drinking water networks, pumping stations, water treatment, fire protection networks, irrigation networks, and sewage and rainwater drainage systems.

Important Notes:
The flange adaptors do not prevent pipe pull-out, so external restraint is necessary. They are not recommended for use with PE pipes. During storage, the adaptors should be protected from adverse weather and pollution to prevent deterioration.

Tests:
Sealing performance tests are conducted according to ISO2531 and EN14525 standards.

Materials and Standards:
The body and counter flange are made of ductile iron (EN-GJS-500-7 EN 1563), the seal is made of EPDM (EN 681-1), and the fixings are stainless steel A2 (DIN603 / ISO4032).

Installation Guidelines:
Before installation, ensure the EPDM gasket and coating are suitable for the conveyed medium. Follow all safety rules and regulations, especially when dealing with pipes that may contain asbestos. The adaptors are supplied ready-assembled and require no disassembly.
See more

Catalog excerpts

METEOR WIDE TOLERANCE FLANGE ADAPTOR-1

METEOR DATASHEET METEOR WIDE TOLERANCE FLANGE ADAPTOR Enables the jointing of pipes and flanges of different materials and outside diameters. Description: • Wide tolerance: on average 25mm. • Small number of models to cover a Nominal diameter. • Reliability Guaranteed leak-tightness by compressing the gasket between the end rings and the sleeve onto the pipe. Optimal protection against corrosion: epoxy powder coating (min. 250µm) and stainless steel nuts and bolts. • Easy and fast installation: Angular deflection of ± 6°. Compensates for pipe misalignment Absorbs pipe expansion and contraction • Conformity to standards EN14525 : “Ductile iron wide tolerance couplings and flange adaptors for use with pipes of different materials: Ductile iron, Grey iron, Steel, PVC-U, PE, Fibrecement”. NF A 48-830 : “Foundry products – Spheroïdal graphite cast iron fittings for PVC drinking water pipes under pressure.” EN545 : “Ductile iron pipes, fittings, accessories and their joints for water pipelines – requirements and test methods.” ISO2531 : “Ductile iron pipes, fittings, accessories and their joints for water applications.” • Approval ACS (Attestation de conformité sanitaire) Gasket and coating with approvals ACS, WRAS, KIWA, KTW W270 Important notes These flange adaptors do not prevent pipe pull-out. The user must ensure that adequate external restraint to the pipework is provided. Not recommended for PE pipes. Characteristics • Range: DN40 – DN300 (OD44-361mm) • For larger DN, please contact us. • Maximum working pressure: PFA16 • Operating temperature: +0°C to +60°C • Installation torque: 40 N m. Applications • Drinking water networks. • Pumping stations, water treatment. • Fire protection networks. • Irrigation networks. • Sewage network and rain water drainage. Tests • Sealing performance tests according to ISO253

 Open the catalog to page 1
METEOR WIDE TOLERANCE FLANGE ADAPTOR-2

Prior to installation:  Check if the quality of the EPDM gasket and coating of the flange adaptor are suitable for the conveyed medium.  During storage (1 year maximum), the Meteor flange adaptor must be protected from any adverse weather and pollution in its original packaging so as to protect it against aggressive conditions (the sun's rays and the heat), to avoid any deterioration of the elastomers and the coating. Ensure that the box is stored in a stable position. Take care not to damage the coating and joints during installation.  Before starting work, ensure that all safety rules are...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.