Catalog excerpts
BA526C N fast resp EW onse barg raph Power supply for optional separately powered backlight 2-wire 4/20mA analogue & digital indicator General purpose Optional alarm outputs Shown with optional separately powered backlight The BA526C is a new combined analogue and digital indicator which replaces the BA526. It offers enhanced features and improved visibility in a shorter enclosure. Like its predecessor, the BA526C displays the current flowing in a 4/20mA loop on a 100 segment bargraph and in accurate engineering units on a digital display. The instrument is loop powered but only introduces a 1V drop allowing it to be installed in series with almost any 4/20mA loop. Main application of the BA526C is to display a measured variable or control signal in a process area. For level and similar measurements the combination of an analogue and digital display provides magnitude and trend information from the bargraph, plus accurate readings in engineering units from the digital display. The relative magnitude of variables can be effectively presented by mounting BA526C indicators side by side. An optional 16 point lineariser enables the BA526C to display non linear variables in linear engineering units. Control and calibration of the combined indicator is performed via the front panel tactile push-buttons. Using these buttons the operator can temporarily display the measured variable as a percentage of span, the input current in mA and the numerical display at 4 and 20mA input. All the calibration functions are contained in easy to understand menus which may be protected by a four digit user selectable security code. The analogue bargraph which contains 100 segments, provides a rapid indication of the input current, enabling an operator to quickly assess the magnitude and trend of a process variable. The bargraph displays zero to full scale for a 4 to 20mA input, but may be calibrated to show deviation from any input current. Either a column or a single segment display may be selected and if only the analogue display is required, the digital display may be disabled. Separately powered backlighting is available as an option. The orange output enhances daylight contrast and enables the display to be read when the instrument is installed in a poorly illuminated area. Optional alarms provide two galvanically isolated solid state outputs which may be independently programmed for high or low operation with a normally open or closed output. For easy comparison with the 4/20mA input, both setpoints are displayed on a second bargraph together with annunciators showing the status of both alarms. Loop powered only 1.1V drop Optimum visibility 100 segment bargraph plus digital display Optional: Display backlight Alarms Lineariser 144 x 48mm DIN enclosure with IP65 front The IP65 front panel is a robust, easy to clean Noryl moulding surrounding an armoured glass window. A captive neoprene gasket provides a seal between the instrument enclosure and the panel. Reliability is ensured by an ISO9001 approved quality control system supported by a three year guarantee. The BA526C is protected from reverse connection and overrange input currents, and incorporates extensive radio frequency filtering to comply with the European EMC Directive. If flammable atmospheres are present the BA326C should be used. This has the same features as the BA526C and has been certified intrinsically safe in both Europe and the USA. BEKA associates Ltd. Old Charlton Rd. Hitchin, Hertfordshire, SG5 2DA, U.K. Tel. (01462) 438301 Fax (01462) 453971 e-mail sales@beka.co.uk www.beka.co.uk
Open the catalog to page 1Display Type Reading rate Analogue Digital Analogue 4 per second 2 per second 95mm long 100 segment column or single segment. Range 0 to100% for 4 to 20mA input Digital 41/2 digit (-19999 to 19999) 5.5mm high; selectable dummy trailing zero extends display range to ( -19990 to 99990). Span Adjustable between 0 & ±19999 Zero Adjustable between ±19999 with 4mA input Decimal point 1 of 5 positions or absent Polarity Automatic minus sign Direction Display may increase or decrease with increasing current. Over & 4 least significant digits are blanked underrange Push-buttons Down button Up button...
Open the catalog to page 2All BEKA catalogs and technical brochures
-
BA684DF-P
2 Pages
-
BA390S
2 Pages
-
BA390
2 Pages
-
BA627E
2 Pages
-
BA627E-SS
2 Pages
-
Edition 9 catalogue
335 Pages
-
LED Panel Lamp BA590
2 Pages
-
BA524G, BA524G-SS
2 Pages
-
BA504G BA504G-SS
2 Pages
-
Advisor A90-SS
2 Pages
-
Advisor A90
2 Pages
-
BA490
2 Pages
-
BA568E
2 Pages
-
BA514G
2 Pages
-
BA590
2 Pages
-
BA567E-SS
2 Pages
-
BA367E
2 Pages
-
BA338E
2 Pages
-
BA444NDF-P
2 Pages
-
BA644DF-F
2 Pages
-
BA688CF-P
2 Pages
-
BA307E-SS
2 Pages
-
BA307NE
2 Pages
-
BA307E
2 Pages
-
BA304NG
2 Pages
-
BA304E
2 Pages
-
BA304G
2 Pages
-
BA201
2 Pages
-
Advisor A85
2 Pages
-
Advisor A80
2 Pages
-
Advisor A75
2 Pages
-
Advisor A70
2 Pages
-
ba324g
2 Pages
-
a75
2 Pages
-
Edition 8 catalogue
182 Pages
Archived catalogs
-
Intelligent displays summary
6 Pages
-
Product Summary 2006
6 Pages