Hazardous area Safe area One input rate totaliser Intrinsically safe for use in all gas hazardous areas Zener barrier or galvanic isolator Flowmeter with proximity detector, magnetic pick-off, voltage pulse, switch contact or open collector output Isolated pulse output Shown with optional backlight International intrinsic safety certification allows the BA338E rate totaliser to be installed worldwide. When configured to operate with a flowmeter having a voltage or magnetic pick-off output, the input terminals comply with the requirements for simple apparatus reducing system design and documentation. All input safety parameters are the same or greater than those for the preceding BA338C, thus allowing the BA338E to safely replace the earlier model. Main application of the BA338E is to process the pulse output from a hazardous area flowmeter such as a turbine meter and simultaneously display the rate and total flow in engineering units within the hazardous area. The BA338E will compensate for flowmeter nonlinearity using up to sixteen flowmeter K-factors which can be entered on-site. Display backlighting, which is internally powered from the totaliser, is available as a factory fitted option. It provides green background illumination enhancing daylight viewing and allowing the display to be easily read at night or when the totaliser is installed in a poorly illuminated area. IP66 front panel protection with a neoprene gasket to seal the joint between the totaliser and the instrument panel allow the BA338E to be installed in areas that will be washed down. To simplify installation and maintenance, the totaliser has removable terminal blocks allowing panel wiring to be completed before the instrument is installed. Open collector pulse output will synchronously retransmit the rate totaliser input pulse, or a pulse when the least significant digit of the total display is incremented. magnetic pick-off, switch contact, proximity detector, open collector or voltage pulse. u Separate rate and total The BA338E is a third generation intrinsically safe rate totaliser that is compatible with the earlier BA338C, but has a much larger display, a lineariser and an isolated synchronous pulse output. The totaliser is easy to use and can be configured on-site to operate with flowmeters having a magnetic pick-off, switch contact, proximity detector, open collector or a voltage pulse output. A slide-in scale card simplifies identification and international intrinsic safety certification permits worldwide installation. The large display has high contrast and a very wide viewing angle enabling the rate totaliser to be read in most lighting conditions over a wide temperature range. Rate of flow may be displayed in almost any units of measurement per second, minute or hour. Total flow may be shown in the same or in different units and the total display may be reset using the front panel push buttons or an external contact closure. An optional isolated 4/20mA output may be configured to produce an analogue output proportional to any part of the rate or total display. The output is galvanically isolated and has been certified as a separate intrinsically safe circuit complying with the requirements for simple apparatus thus simplifying connection to other instruments. enclosure with IP66 front protection. u Lineariser u Isolated pulse output u Optional: Backlight Dual alarms 4/20mA output Optional dual alarms can switch hazardous area loads such as a sounder or solenoid valve, or safe area loads via a Zener barrier or isolator. The two galvanically isolated, solid state voltage free outputs may be independently conditioned as rate or total alarms with normally open or closed outputs. Annunciators on the BA338E display show the status of both alarm outputs. When panel space is limited the BA337E provides similar features in a smaller 94 x 48mm enclosure. BEKA associates Ltd. Old Charlton Rd. Hitchin, Hertfordshire, SG5 2DA, U.K. Tel. (01462) 438301 Fax (01462) 453971 e-mail sales@beka.co.uk www.beka.co.uk
Open the catalog to page 1DIMENSIONS (mm) Power supply Voltage 10 to 28V from a Zener barrier or galvanic isolator Current 16mA max plus 16mA for optional backlight Input Switch contact Proximity detector (NAMUR) Open collector Magnetic pick-off Voltage pulse (low) Voltage pulse (high) Lower Upper switching thresholds Panel cut-out Recommended panel cut-out DIN 43 700 138.0 +1.0/ -0.0 x 68.0 +0.7/ -0.0 To achieve an IP66 seal between the instrument and the panel 136.0 +0.5/-0.0 x 66.2 +0.5/-0.0 Four panel mounting clips must be used Frequency Switch contact Other inputs All inputs Display Type Zero blanking...
Open the catalog to page 2All BEKA catalogs and technical brochures
-
BA684DF-P
2 Pages
-
BA390S
2 Pages
-
BA390
2 Pages
-
BA627E
2 Pages
-
BA627E-SS
2 Pages
-
Edition 9 catalogue
335 Pages
-
LED Panel Lamp BA590
2 Pages
-
BA524G, BA524G-SS
2 Pages
-
BA504G BA504G-SS
2 Pages
-
Advisor A90-SS
2 Pages
-
Advisor A90
2 Pages
-
BA490
2 Pages
-
BA568E
2 Pages
-
BA514G
2 Pages
-
BA590
2 Pages
-
BA567E-SS
2 Pages
-
BA367E
2 Pages
-
BA444NDF-P
2 Pages
-
BA644DF-F
2 Pages
-
BA688CF-P
2 Pages
-
BA307E-SS
2 Pages
-
BA307NE
2 Pages
-
BA307E
2 Pages
-
BA304NG
2 Pages
-
BA304E
2 Pages
-
BA304G
2 Pages
-
BA201
2 Pages
-
Advisor A85
2 Pages
-
Advisor A80
2 Pages
-
Advisor A75
2 Pages
-
Advisor A70
2 Pages
-
ba324g
2 Pages
-
a75
2 Pages
-
ba526c
2 Pages
-
Edition 8 catalogue
182 Pages
Archived catalogs
-
Intelligent displays summary
6 Pages
-
Product Summary 2006
6 Pages