1. Catalogs
  2. BEIJING TIME VISION AI INSTRUMENT LTD.
  3. Ultrasonic Thickness Gauge TIME®2190

Ultrasonic Thickness Gauge TIME®2190

Ultrasonic Thickness Gauge TIME®2190

Ultrasonic Thickness Gauge TIME®2190

Product catalog summary
Technical Specifications
  • Measurement Range: 0.20~500mm
  • Velocity Range: 508m/s~18699m/s
  • Display: Color TFT LCD, 320x240 pixels
  • Pulse Generator: Adjustable Square Wave Pulse Generator
  • Resolution: 0.001mm, 0.01mm, or 0.1mm optional
  • Emission Voltage: 60V, 110V, 150V, 200V optional
  • Gain Range: 0-99dB, 1dB step
  • Frequency Range: 0.5 MHz~20MHz
  • Measurement Rate: Standard (4Hz), Fast (20Hz)
  • Data Storage: 500 data files, each storing 1000 measurements and waveforms
  • Working Temperature: 0°C~40°C
  • Power: Three AA batteries or NiMH batteries
  • Dimensions: 187mm×87mm×43mm
  • Weight: 360g
Features
  • A-scan waveform display for echo analysis
  • Compatible with single and dual element transducers
  • Echo-echo measures true metal thickness, ignoring coatings
  • Thru-coat technology measures metal and nonmetallic coatings
  • Signal auto-amplification function
  • Adjustable voltage variable pulse width square wave pulse generator
  • Single value B-scan display function
  • Fast measurement mode up to 20 times per second
  • Data output to removable MicroSD memory card, storing up to 500,000 values
Transducer Types and Measurement Ranges
  • 5MHz double element narrow pulse transducer: 1.2~225.0mm
  • 5MHz single element contact transducer: 5.0~225.00mm
  • 2MHz double element transducer: 3.0~300.00mm
  • 1MHz single element contact transducer: 10~500.00mm
  • 15MHz single element delay block transducer: 3.0mm~20.0mm
  • 2.5MHz double element transducer: 2.0mm~300.0mm
  • 7MHz double element transducer: 0.75mm~75.0mm
  • 5MHz high-temperature double element transducer: 1.2mm~225.0mm
  • 1MHz double element transducer: 3.0mm~500.0mm
  • 15MHz single element pen type transducer: 3mm~8.0mm
Detecting Modes
  • Standard Echo Detection Mode: Measures thickness based on time interval between excitation pulse and first back wall echo.
  • Automatic Echo-Echo Detection Mode: Measures thickness of materials with paint or coating by eliminating paint thickness.
  • Paint Thickness Measurement: Simultaneously displays layer and substrate thickness.
  • Mode 1: Measures time interval between main pulse signal and first back-wall echo using contact transducer.
  • Mode 2: Measures time interval between interface echo and first back-wall echo using delay line or immersion transducer.
  • Mode 3: Measures time interval between two successive back-wall echoes using delay line or immersion transducer.
See more

Catalog excerpts

Ultrasonic Thickness Gauge TIME®2190-1

Beijing TIME High Technology Ltd. Standard Delivery ●Main unit ●5MHz double element transducer ●Couplant ●AA battery ●TIME certificate ●Warranty card ●Instruction manual Optional Accessory ●Standard block ●Optional transducers (see next page) Technical Specification Measurement range single and dual element transducers Display screen Pulse generator Adjustable Square Wave Pulse Generator Emission voltage 60V, 110V, 150V, 200V optional varies with transducer frequency Gain range Frequency range Measurement rate Transducer settings 10 sets of fixed transducer setting and 22 sets of custom transducer setting 500 data files, each capable of storing 1000 measurements and waveforms Working temperature and measurement of complex workpiece ●Compatible with many types of transducers, both Velocity range Data Storage ●A-scan waveform can be displayed for echo analysis Emission pulse width three AA battery or NiMH batteries ●Users can set blanks to shield aftershocks or clutter ●Echo-echo measures the true metal thickness while ignoring the thickness of coating layer. ●Thru-coat technology measures metal and nonmetallic coating thickness. ●Signal auto-amplification function ●Adjustable voltage variable pulse width square wave pulse generator ●Single value B-scan display function ●Fast measurement mode up to 20 times per second ●Set upper and lower limits and alarm ●Data can be output to a removable MicroSD memory card. Can store up to 500,000 measured values and waveforms.

 Open the catalog to page 1
Ultrasonic Thickness Gauge TIME®2190-2

Beijing TIME High Technology Ltd. Transducer Measurement Range Transducer Type Measuring Range(steel) Indication Error Using Mode Standard Echo-Echo 5MHz single element contact transducer DEFM1-SE-5MHZ Standard Echo-Echo TSTU32 2MHz double element transducer TSTU32-2.0MHZ 1MHz single element contact transducer DEFM1-SE-1MHZ 15MHz single element delayblock transducer 5MHz double element narrow pulse transducer DK537EE-5MHZ Interface-echo Echo-echo 2.5MHz double element transducer SZ2.5P-2.5MHZ 7MHz double element transducer 7PD6-7.0MHZ Standard Echo-echo 5MHz double element narrow pulse transducer...

 Open the catalog to page 2
Ultrasonic Thickness Gauge TIME®2190-3

Beijing TIME High Technology Ltd. Detecting Modes ●The standard echo detection mode measures the thickness based on the time interval between the excitation pulse and the first back wall echo. User can measure uncoated materials in this mode. ●Automatic echo-echo detection mode allows thickness measurement of materials with paint or coating because the time interval between two successive back-wall echoes eliminate paint or coating thickness. ●Paint thickness measurement can simultaneously display layer thickness and substrate thickness. ●The instrument includes three detection modes (Mode 1,...

 Open the catalog to page 3

All BEIJING TIME VISION AI INSTRUMENT LTD. catalogs and technical brochures

  1. TIME5300

    1  Page

  2. TIME 2020

    76  Pages

Archived catalogs

  1. TH1101

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.