1. Catalogs
  2. BEIJING TIME VISION AI INSTRUMENT LTD.
  3. TIME5120 Portable Rebound Hardness Tester

TIME5120 Portable Rebound Hardness Tester

TIME5120 Portable Rebound Hardness Tester

Product catalog summary
Specifications:
  • Impact Device: Standard impact device D integrated.
  • Hardness Scales: HL, HB, HRA, HRB, HRC, HV, HS.
  • Measuring Range: 170 to 960 HLD.
  • Accuracy: 6 HLD.
  • Memory: Current value.
Workpiece Requirements:
  • Minimum Surface Roughness: 1.6 µm (Ra).
  • Maximum Hardness: 960 HLD.
  • Minimum Radius: Rmin = 50 mm (with support ring Rmin = 10 mm).
  • Minimum Thickness of Hardened Layers: 0.8 mm (refer to page 14).
Device Specifications:
  • Indentation Depth: 24 µm.
  • Charging Time: 2 to 3 hours.
  • Continuous Working Time: 8 hours.
  • Power Supply: Rechargeable Li battery 3.7V.
  • Operating Temperature: 0 to 40°C.
  • Dimensions: 145 × 35 × 30 mm.
  • Weight: 130 g.
See more

Catalog excerpts

TIME5120 Portable Rebound Hardness Tester-1

Beijing TIME High Technology Ltd. Standard Delivery •Main unit 1 •Instruction manual Optional Accessory •Support rings Features • Light Mini Unit with simple menu, easy and convenient to use • Universal D type standard impact device for the majority of hardness testing requirements •Wide range measurements in HLD and conversion among other 6 common hardness scales •Measuring Direction: Any direction 360° •Software calibration •Battery indicator with auto power off in low battery Standard impact device

 Open the catalog to page 1

All BEIJING TIME VISION AI INSTRUMENT LTD. catalogs and technical brochures

  1. TIME5300

    1  Page

  2. TIME 2020

    76  Pages

Archived catalogs

  1. TH1101

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.