!"#$%&'( DRY TYPE AIR CORE REACTORS BPEG ! " # $ % BEIJING POWER EQUIPMENT GROUP
Open the catalog to page 1![BPEG Air-core Reactors - 2](https://img.directindustry.com/pdf/repository_di/224007/bpeg-air-core-reactors-938711_2m.jpg)
Brief Introduction = !"#$%(BPEG) !"#$%&'() !"#$%&'() !"BPEG Trench Electric Beijing Power Equipment Group (BPEG) has become the largest synthetical enterprise among those of electric power industry in China. The Special Electric Equipment Works,as a member of BPEG,is the main manufactruer of air core reactor,line trap and coupling filter in China. BPEG introduced a complete set of modern advanced manufacture technique of line trap from Trench Electric Corporation Ltd., Canada in 1986,and based on which series of highly reliable dry-type air-core reactors were developed by ourselves. BPEG...
Open the catalog to page 2![BPEG Air-core Reactors - 3](https://img.directindustry.com/pdf/repository_di/224007/bpeg-air-core-reactors-938711_3m.jpg)
Brief Introduction Operation Conditions Order Information Type Meaning Technical Parameters Table
Open the catalog to page 3![BPEG Air-core Reactors - 4](https://img.directindustry.com/pdf/repository_di/224007/bpeg-air-core-reactors-938711_4m.jpg)
simple for maintenance. Their life expect ancy is more than 30 years. Reactor, Test Lab Reactor, Damping Reactor, Splitting Reactor, Neutral-Grounding Current-limiting Reactor, Starting They are parallel connected with the transformer tertiary winding section parallel-insulated aluminum wires, the whole reactor is integrated by epoxy fiberglass hardened in drying store, the leading-out ends of each winding layer are welded to upper and lower spider arms, the reactor is cooled with neutral air cooling, the surface of reactor is painted with resist aging, ultraviolet-proof insulation...
Open the catalog to page 4![BPEG Air-core Reactors - 5](https://img.directindustry.com/pdf/repository_di/224007/bpeg-air-core-reactors-938711_5m.jpg)
Current-limiting Reactors They are series connected with power system (bus, line and load) They can reduce the short circuit current to allowable level for other equipment. Smoothing Reactor It is a single phase coil. It is used to reduce the magnitude of the harmonic currents or voltage in a DC system, and restrain the run speed and the peak value of short circuit current. They are used in HVDC transmission system and also series connected with large rectification-feed DC motor in steel and non-ferrous metallurgical plant. Test Lab Reactors They are installed in high voltage test lab, and...
Open the catalog to page 5![BPEG Air-core Reactors - 6](https://img.directindustry.com/pdf/repository_di/224007/bpeg-air-core-reactors-938711_6m.jpg)
OPERATING CONDITIONS 1. Operating site : Outdoor or Indoor 4. Maximum wind speed: 35m/s 5. Relative humidity: 6. Earthquake acceleration: Horizontal:0.3g Vertical:0.15g (Upon Request) 7. Pay attention to ventilation and coolness for indoor use. 8. Mounting spot must be clean without harmful gas,steam and conductive or explosive dust. !" NOTE: Please contact with BPEG if you have other special requirements. ORDER INFORMATION SHUNT REACTOR 1.Rated Frequency 2.Rated System Voltage 3.Rated Voltage 4.Rated Capacity of Single Phase 5.Maximum Continuous Operation Voltage 6.Rated Reactance...
Open the catalog to page 6![BPEG Air-core Reactors - 7](https://img.directindustry.com/pdf/repository_di/224007/bpeg-air-core-reactors-938711_7m.jpg)
CURRENT- LIMITING REACTOR 1.Rated Frequency 2.Rated System Voltage 3.Reactance Percent 4.Rated Current 5.Rated Short-Time Current and Duration 6.Asymmetrical Peak Value of Current 7.Rated Reactance 8.Insulation Level 9.Outdoor or Indoor Mounting 10.Mounting and Terminal Orientation FILTER (ADJUSTABLE) REACTOR 1. System Voltage 2. Rated Power Frequency 3. Rated Current at Power Frequency 4. Rated Voltage at Power Frequency 5. Rated Inductance 6. Rated Q-Factor 7. Rated Short-Time Current and Duration 8. Rated Harmonic Frequency 9. Rated Current at Harmonic Frequency 10.Insulation Level...
Open the catalog to page 7![BPEG Air-core Reactors - 8](https://img.directindustry.com/pdf/repository_di/224007/bpeg-air-core-reactors-938711_8m.jpg)
!"# (TCR) Thyristor Controlled Shunt Reactor (TCR) !(kVA) Rated Capacity(one phase) !(kVA) Rated Capacity(one phase) !" Shunt Reactor !" Shunt Reactor !"#$% Applicable for Adjustable Reactance C K K T (%) Reactance Percent !(kV) System Voltage !(kVA) Rated Capacity(one phase) ! Adjustable Reactance (%) Reactance Percent !(kV) System Voltage !(kVA) Rated Capacity(one phase) Air Core !" Series Reactor !" Series Reactor !"#$% Applicable for Fixed Reactance 3 LKKT !"#$%&'( Filter Reactor !(A) Rated Current !(kV) System Voltage !(A) Rated Current !(kV) System Voltage ! Adjustable Reactance Air...
Open the catalog to page 8![BPEG Air-core Reactors - 9](https://img.directindustry.com/pdf/repository_di/224007/bpeg-air-core-reactors-938711_9m.jpg)
(%) Reactane Percent (%) Rated Reactane !" Current-Limiting Reactor !" Splitting Reactor !" Damping Reactor !" Smoothing Reactor 8 ZJKK !"#$%&'()*+ Neutral-Grounding Reactor 9 QKK !"#$%&'( Motor Starting Reactor Q K K (%) Reactance !( ) Rated Reactance !" Motor Starting Reactor
Open the catalog to page 9![BPEG Air-core Reactors - 10](https://img.directindustry.com/pdf/repository_di/224007/bpeg-air-core-reactors-938711_10m.jpg)
! Type Meaning 10 JKK !"#$%&'( Load Sharing Reactor Lightning Defence !" Load sharing Reactor 12 SYKK !"#$%&'( Testing Reactor SY K K !(mH) Rated inductance !(A) Impulse Current !(kV) System Voltage Air Core Reactor Testing ISO9001 !"##$ 2000 !" e of ISO9001 Quality System acquired in 1997 and reviewed in 2000
Open the catalog to page 10![BPEG Air-core Reactors - 11](https://img.directindustry.com/pdf/repository_di/224007/bpeg-air-core-reactors-938711_11m.jpg)
!"#$%& Three-phase in a line arrangement !"#$%&'()*+,-./012 jáåáãìã=ã~ÖåÉíáÅ=ÅäÉ~ê~åÅÉ ! Three-phase stacked arrangement !"#$%&'()*+,-./012 jáåáãìã=ã~Ö
Open the catalog to page 11![BPEG Air-core Reactors - 12](https://img.directindustry.com/pdf/repository_di/224007/bpeg-air-core-reactors-938711_12m.jpg)
! ! Two-phase stacked and one phase single arrangment !"#$%&'()* Outdoor Gradient post mounting of shunt reactor Rainproof Grid ! Top Hat Nonmagnetic Pedestal !" ! Fore-buried iron !"# Channel Steel !"# !"#$%&'( Outdoor mounting of shunt reactor !"#$%& Three-phase in a triangle arrangement ! RAINPROOF GRID
Open the catalog to page 12![BPEG Air-core Reactors - 13](https://img.directindustry.com/pdf/repository_di/224007/bpeg-air-core-reactors-938711_13m.jpg)
!"#$%&'() ! NUM ! !"# !" QR kçíÉW qÜÉNUM áë=éêÉÑÉê~ÄäÉ=áÑ=íÜÉ=íÉêãáå~ä=çêáÉåí~íáçå=Ñçê=çåÉJéÜ~ëÉ=áë=åçí=ëéÉÅáÑáÉÇK qÜÉ=QR áë=éêÉÑÉê~ÄäÉ=áÑ=íÜÉ=íÉêãáå~ä=çêáÉåí~íáçå=Ñçê=íÜêÉÉJéÜ~ëÉ=ëí~Åâ