CATALOGUE OF ECO-SMART PRO PLUS ERV
1 / 9Pages

Catalog excerpts

CATALOGUE OF ECO-SMART PRO PLUS ERV - 1

FRESH AIR FOR YOUR LIFE Beijing Holtop Air Conditioning Co., Ltd. Factory address : No. 5 Yard, 7th Guanggu Street, Badaling Economic Development Zone, Yanqing District, Beijing, China International marketing center Room 2101, Headquarter Center No. 25, Tian An Hi-Tech Ecological Park, No. 555 Panyu Ave, Guangzhou, China Tel: 86-20-39388201-8023 Website: www.holtop.com E-mail: info@holtop.com * Data is subject to changes without notification due to product improvement ECO-SMART PRO PLUS Energy Recovery Ventilators

Open the catalog to page 1
CATALOGUE OF ECO-SMART PRO PLUS ERV - 2

Night Time Free Cooling Timer Operation Supplies cool air during nighttime to reduce cooling load ON/OFF timer can be set by users for automatic control to minimize the unnecessary operation Indoor Temp Outdoor Temp Comfort Air + Energy Saving Seasonal Auto Operation Controls the fan speed automatically according to CO2 level Automatically changes operation mode based on the weather condition by sensing different temperature. Compare to natural ventilation High efficiency heat exchanger recover wasted energy while ventilating. ERV saves energy Max.39% compare to natural ventilation FRESH...

Open the catalog to page 2
CATALOGUE OF ECO-SMART PRO PLUS ERV - 3

Energy Recovery Ventilators Model Descriptions ECO-SMART PRO Energy Recovery Ventilators Installation type, D for suspended type Physical filtering Energy recovery Slim design Good insulation Easy access Silent operation ECO-SMRAT PRO energy recovery ventilator Rated airflow (m3/h), for airflow more than 1000m3/h, H is for a hundred Energy saving 1 is without bypass, 2 is with bypass. Central control C is built in PM2.5 filter, D is without PM2.5 filter Filter alarm Series Code Smart control D is for advanced intelligent control, C is for black cool intelligent control

Open the catalog to page 3
CATALOGUE OF ECO-SMART PRO PLUS ERV - 4

Energy Recovery Ventilators Durable Appearance Design New Primary Filter New primary filter is made of aluminium alloy frame and rubber filtration materials with nicer appearance and longer service life. • Anticorrosive, beautiful, durable • Excellent anti-corrosion performance • Metallic texture EPS Structure Sub-HEPA F9 Filter Integrated Optional • Integrated EPS for good insulation and air tightness. • No condensation. • Light weight, heat preserve, silent, environmental friendly, no odor Optional sub HEPA F9 filter, particle diameter under 2.5μm can be filtered effectively, IAQ (indoor...

Open the catalog to page 4
CATALOGUE OF ECO-SMART PRO PLUS ERV - 5

Energy Recovery Ventilators Linkage with External A/C System or BMS Control Energy Efficiency Class of A Specifications Model Dimensions Higher Energy Efficiency and Ecology by Powerful Motors Full series Eco Smart energy recovery ventilator are built with higher efficiency brushless DC motors, power consumption is reduced by up to 70%, resulting in significant energy saving. VSD control is suitable for most of the projects air volume and ESP requirement. Running costs comparison of Eco-vent pro ERV and Eco-smart pro ERV 60 50 40 Costs reduce per year Electric charge: 0.08 USD/Kw.h

Open the catalog to page 5
CATALOGUE OF ECO-SMART PRO PLUS ERV - 6

Energy Recovery Ventilators Good Thermal Insulation The whole series are intergated with EPS structure, effectively preventing condensation, and improving thermal insulation and saving energy consumption. New Primary Filter New primary filter is made of aluminium alloy frame and rubber filtration materials with nice appearance and longer service life. Physical filtering Energy recovery Good insulation Easy access Silent operation Bypass function Energy saving Smart control Filter alarm Central control Sub-HEPA F9 Filter Integrated Optional Optional sub HEPA F9 filter, particle diameter...

Open the catalog to page 6
CATALOGUE OF ECO-SMART PRO PLUS ERV - 7

Energy Recovery Ventilators New Compact Structure New airflow channels are to increase heat exchange surface and improve energy recovery efficiency. Easy Maintenance • Regular access door is for maintenance of primary filter, PM2.5 filter and heat exchangers. Specifications Winter • Increase two professional access doors for the control and fan maintenance. Higher Efficiency with 3rd Generation Enthalpy Exchanger The 3rd generation enthalpy exchanger is made of the latest nanofiber structure to ensure higher efficiency. The heat exchange materials are mildew resistance and fire retardance.

Open the catalog to page 7
CATALOGUE OF ECO-SMART PRO PLUS ERV - 8

Energy Recovery Ventilators Optional Filters Specifications Model We also have optional filters for customers to use in different environment of air cleanness. If you need performance curves for different filters, please contact our sales team. Optional Fresh Air Filters: Optional Supply Air Filters: Activated Carbon Primary Filter H13 High Efficient Filter G3 / Activated Carbon Primary Filter Ideal for home and business use Ideal for home and business use Ideal for home and business use Traps 50% of airborne particles Traps 95% of airborne particles Traps 98% of airborne particles Traps...

Open the catalog to page 8
CATALOGUE OF ECO-SMART PRO PLUS ERV - 9

Energy Recovery Ventilators Intelligent Controller Intelligent control HDK-CK-20 Type Black cool intelligent control 10307 Advanced intelligent control Suitable series Temperature display OA/RA/SA/FR temp. OA/RA/SA/FR temp. OA/RA/SA/FR temp. 10 speed Weekly timer Bypass External ON/OFF Comfortable heater control Defrosting CO2 control Filter alarm Fault alarm Data memory Night free cooling BMS integration Humidity control Defrosting heater control Working condition monitor Sleep mode Wifi function *The MOQ for intelligent controller LH-12100 and 10307 is 100pcs. Monitoring indoor air...

Open the catalog to page 9

All Beijing Holtop Artificial Environment Technology Co. catalogs and technical brochures

  1. Heat Wheels