1. Catalogs
  2. BEIJING GFUVE ELECTRONICS CO.,LTD.
  3. FUD-I/U SINGLE PHASE 4-20MA AC VOLTAGE CURRENT TRANSDUCER

FUD-I/U SINGLE PHASE 4-20MA AC VOLTAGE CURRENT TRANSDUCER

FUD-I/U SINGLE PHASE 4-20MA AC VOLTAGE CURRENT TRANSDUCER

FUD-I/U SINGLE PHASE 4-20MA AC VOLTAGE CURRENT TRANSDUCER

Product catalog summary
Technical Specifications
Standard compliance includes GB/T 13850-1998 and IEC688:1992. The device offers accuracy levels of 0.2% and 0.5%, with a consumption of ≤3VA. The accuracy drift is less than 0.2% annually. Insulation voltage is rated at AC 2kV/min with 1mA between input-output/power, and insulation resistance is ≥20MΩ at DC500V. Surge voltage is 5KV with a 1.2/50μs waveform. Response time is ≤350ms.

Input and Output Specifications
The input range is AC 0-10A and AC 0-500V (optional), operating at 50/60Hz. Absorbed power is <0.5VA/450V, <0.2VA/100V, and <0.1VA/5A. Overload capacity for current is 2 times continuously and 30 times for 1 second; for voltage, it is 2 times continuously. Current output load resistance is ≤550Ω, and voltage output load resistance is ≥2kΩ.

Environmental Conditions
Operating temperature ranges from -10 to +50°C with relative humidity (RH) of 20-90% without condensation. Storage conditions allow for temperatures from -40 to +70°C and RH of 20-95% without condensation.

Product Features
The FUD-I/U is a single-phase AC voltage and current transducer that converts measured AC current/voltage to DC current/voltage output according to a linear scale. It boasts excellent temperature characteristics and stability, with a compact and simple configuration.

Model Variants and Customization
Types include single-phase AC current transducer (I), voltage transducer (U), real RMS current transducer (Ir), and real RMS voltage transducer (Ur). AC input options range from 0-1A to 0-10A and 0-70V to 0-500V. Power supply options include AC110V±10%, AC220V±15%, and AC110V-330V. DC output options include 0-5V, 1-5V, 0-20mA, 4-20mA, and RS485.

Installation and Dimensions
The device can be installed using a 35mm DIN sliding-way or M4 screws, with dimensions of 55mm x 75mm x 120mm.

Ordering Information
When ordering, specify the type, input range, output range, and power supply. Example configurations include FUD-I-A2-P2-O4 for a single-phase AC current transducer and FUD-Ur-V3-P2-O4 for a single-phase AC real RMS voltage transducer.
See more

Catalog excerpts

FUD-I/U SINGLE PHASE 4-20MA AC VOLTAGE CURRENT TRANSDUCER-1

GFUVE FUD-I/U POWER TRANSDUCER FUD-I/USingle Phase AC Voltage Current Transducer Changing the measured AC current/voltage to the DC current/voltage output according to the linear scale; Excellent temperature characteristic and good working stability; Configuration compactness and briefness. Features 1. Single phase current/voltage transducer 3. Accuracy class can reach 0.2% 4. AC input range can be customized 5. DC output range can be customized Parameters Technical Index Power Transducer | EDITION : 14-02 | Page 1 of 2 Subject to change without notice

 Open the catalog to page 1
FUD-I/U SINGLE PHASE 4-20MA AC VOLTAGE CURRENT TRANSDUCER-2

FUD-I/U POWER TRANSDUCER @ GFUVE Technical Index Type I: Single phase AC current transducer U: Single phase AC voltage transducer Ir: Single phase AC real RMS current transducer Ur: Single phase AC real RMS voltage transducer AC input A1: 0-1A, A2: 0-5A, A3: 0-10A. Example 1: FUD-I-A2-P2-O4 FUD series single phase AC current transducer Input: AC0-5A Power supply: AC220V±15% Output: DC4-20mA Example 2: FUD-Ur-V3-P2-O4 FUD series single phase AC real RMS voltage Input: AC 0-300V transducer Power supply: AC220V±15% Output: DC4-20mA Please check the type, input range, output range and...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.