Features
  • Wide input voltage range of 100-240VAC.
  • Low power consumption with no-load consumption less than 0.075W.
  • High energy efficiency with power efficiency up to 89%.
  • High reliability compliant with EN60601-1, IEC CLASS Ⅱ, and 2×MOPP insulation protection level, CE certified.
  • Flame retardant insulation using UL94V-0 material.
  • Full protection features including short circuit, over voltage, over current, and self-recovery.
Applications
  • Blood glucose and oxygen meters.
  • COVID-19 PCR test machines.
  • Household beauty devices and physiotherapy equipment.
Description

The ADA360K120S001B is a desktop power adapter with a universal input voltage of 100-240VAC and a single output of 12VDC. It is widely used in portable medical equipment.

Specifications
  • Input Parameters: Voltage range of 100-240VAC, frequency range of 50-60Hz, and maximum input current of 0.7A at 110VAC.
  • Output Parameters: Output voltage of 12VDC with a tolerance of ±5%, output current of 3000mA, and rated power of 36W.
  • Environment: Operating temperature range of -40 to +70℃ and storage temperature range of -40 to +85℃.
  • Protection Functions: Includes long-term short circuit auto recovery, over current auto recovery, and over voltage protection.
  • Reliability: MTBF of ≥100,000 hours at 25℃.
  • Safety Standards: Compliant with medical safety standard EN60601-1 and CE certified.
  • EMC: Meets standards for conducted and radiated emissions, electrostatic discharge, and other electromagnetic compatibility requirements.
Mechanical Specification

Dimensions are 89x51x31mm with a black flame retardant and heat-resistant plastic enclosure. Cooling is achieved through natural air cooling.

Precautions for Use
  • Avoid using the equipment close to or stacked with other equipment to prevent improper operation.
  • Maintain a distance of more than 30cm from portable radio frequency communication equipment to avoid performance reduction.
Revision History
  • Version 00: First edition on 2023-01-11.
  • Version 01: Upgrade version on 2023-05-24.
  • Version 02: Update product pictures on 2023-07-28.
  • Version 03: Update MTBF value on 2024-08-29.

Disclaimer: DWIN reserves the right to make changes to product designs without prior notice. Customers should adhere to all relevant standards and requirements during product application.

See more

Catalog excerpts

ADA360K120S001B-1

36W AC-DC Medical-grade Desktop Power Adapter ADA360K120S001B Wide input voltage: the input working voltage range is 100-240VAC. Low power consumption: No-load <0.075W. High energy efficiency: Six levels of energy consumption, power efficiency up to 89%. High reliability: Compliant with EN60601-1, IEC CLASS Ⅱ and 2×MOPP insulation protection level, CE. Flame retardant insulation: UL94V-0 flame retardant heat resistant material. Full protections: Short Circuit/ Over Voltage/ Over Current/ Self-recovery. Blood glucose meter Blood oxygen meter COVID-19 PCR test machine Household beauty device Physiotherapy equipment 3 Description ADA360K120S001B is a desktop power adapter with a single output. With 100 -240 VAC universal input voltage, it can continuously output any DC voltage of 12VDC, 1M output cable length. Widely used in portable medical equipment . DWIN Technology

 Open the catalog to page 1
ADA360K120S001B-3

4 Naming Convention ADA360K120S001B: Output Voltage 12V ,Output Power 36W ,medical desktop power adapter AC / DC □□ Product Code AD=Isolated AC/DC; DD=Isolated DC/DC Packaging Form A=adapter; M=resin filled power module; P=PCB module Power Coding First two digits multiplied by 10 to the power of the third digit Application Level C=commercial grade T=industrial grade environment application Output Voltage S=standard product 001-999, used to identify different products of the same category Major Upgrade Information A-Z, fixed as A for the first mass production K=medical grade Z=customized product...

 Open the catalog to page 3
ADA360K120S001B-4

5.2 Output Parameter Output Voltage Voltage Tolerance Output Current Line Regulation Load Regulation Ripple & Noise 5.3 Environment Operating Temperature Storage Temperature Power Derating Temperature Coefficient Soldering Temperature 260±5℃ @ Wave Soldering, 5~10s 360±10℃ @ Manual Soldering, 3-5s 5.4 Protection Function Short Circuit Long term short circuit, auto recovery. Over Current Over Voltage Electric Shock Protection DWIN Technology

 Open the catalog to page 4
ADA360K120S001B-5

5.6 Safety Standards / Directives Medical safety 4000VAC @ 1 minute test and the leakage current is smaller than 5mA. Test Level / Note Conducted emission Radiated emission Voltage flicker Harmonic current Test Level / Note Electrostatic Discharge Radiate Susceptibility Electrical Fast Transient burst Conducted Susceptibility Voltage Dips and Interruption 6 Typical Application Circuit Note:EMC has higher requirements without any additional circuit. DWIN Technology

 Open the catalog to page 5
ADA360K120S001B-7

7 Mechanical Specification Dimension Enclosure Material Black flame retardant and heat resistant plastics(UL94V-0) Cooling mode Power and cable specification ul2464 × 20Awg * 1m, 5.5 * 2.5 straight head + magnetic ring + SR DWIN Technology

 Open the catalog to page 7
ADA360K120S001B-9

8 Precautions for Use Avoid using the equipment close to or stacked with other equipment, which may lead to improper operation. If it must be used close to or stacked, pay attention to observe and verify the equipment and other equipment to ensure normal operation. The use of other accessories, sensors and cables provided by the equipment manufacturer may increase the electromagnetic radiation or reduce the immunity. The distance between the portable radio frequency communication equipment and the equipment should not be greater than 30cm, otherwise the performance of the equipment may be reduced....

 Open the catalog to page 9
ADA360K120S001B-10

9 Revision History Version 00 Description First edition Author Kaya Upgrade version Update product pictures Update MTBF Value Disclaimer: The product design is subject to alternation and improvement without prior notice. Please contact us if you have any questions about the use of this document or our products, or if you would like to know the latest information about our products:  Customer Service Email: [email protected] DWIN Developer Forum: https://forums.dwin-global.com/ Thank you all for continuous support of DWIN, and your approval is the driving force of our progress! Important Disclaimer...

 Open the catalog to page 10

All Beijing DWIN Technology Co., Ltd. catalogs and technical brochures

  1. HR4 8545 10.4

    12  Pages

  2. HR4 8537 8.0

    12  Pages

  3. YF07002

    12  Pages

  4. YF04303

    12  Pages

  5. GME0831B

    14  Pages

  6. TP024Z0001A

    14  Pages

  7. ADA360K240S001B

    10  Pages

  8. TC040C15W04

    13  Pages

  9. TC040C12U/W00

    7  Pages

  10. TC040C17W00

    9  Pages

  11. HDW080_A5001L

    5  Pages

  12. HDW043_A5001L

    6  Pages

  13. HDW156_001L

    4  Pages

  14. HDW104_001RTD

    5  Pages

  15. HDW101_007L

    5  Pages

  16. HDW070_A5001L

    6  Pages

  17. IOT Catalog

    16  Pages

  18. HDW215_001L

    4  Pages

  19. HDW104_001L

    3  Pages

  20. HDW101_001L

    4  Pages

  21. HDW050_003L

    4  Pages

  22. HDW043_001L

    4  Pages

  23. EV121X0M-N10

    36  Pages

  24. EV101WXM-N10

    34  Pages

  25. ET121S0M-N11

    25  Pages

  26. HDW070_007L

    3  Pages

  27. LQ035NC111

    29  Pages

  28. TN028C11U04

    8  Pages

  29. TC070C12U00

    6  Pages

  30. TC043C12U00

    3  Pages

  31. TC041C11W04

    4  Pages

  32. TC040C11U04

    4  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.