General Description: The 982R series differential pressure transmitters are designed for measuring differential pressure, overpressure, and vacuum. They feature an adjustable pressure range and provide an output signal.
Applications: These transmitters are suitable for monitoring gaseous, non-combustible, and non-aggressive media. Common applications include building automation, air conditioning systems, clean room monitoring, valve and flap control, filter, ventilator, and blower monitoring, and air flow control.
Key Features:
  • Adjustable Pressure Range: The pressure range can be reduced to 50% of its factory set full scale value using a push-button.
  • Output Signal: Options include 0-10 V or 4-20 mA, with other signals available upon request.
  • Offset Calibration: Easy zero calibration via a push-button when the transmitter is depressurized.
  • Configurable Response Time: The response time can be adjusted using a jumper for either slow (factory setting) or fast response.
  • Volume Flow Measurement: The output signal can be programmed to a square root shape by the factory.
  • Reset Function: The transmitter can be reset to factory settings by pressing the push-button for more than 10 seconds.
Technical Specifications:
  • Measuring Method: Piezoresistive pressure transducer.
  • Mounting Position: Can be mounted in any position with zero offset calibration to eliminate position error.
  • Supply Voltage: 18-30 VAC/VDC for 3-wire version, 18-30 VDC for 2-wire version.
  • Output Signal: 0-10 V or 4-20 mA for 3-wire version, 4-20 mA for 2-wire version.
  • Maximum Current Draw: Less than 40 mA for 3-wire/0-10 V, less than 60 mA for 3-wire/4-20 mA, less than 21 mA for 2-wire/4-20 mA.
  • Medium: Air and non-combustible, non-aggressive gases.
  • Temperature Range: -20 to 70°C.
  • Linearity: ≤ ±0.5% FS, minimum ±1 Pa.
  • Uncertainty: ±1% FS, minimum ±1 Pa.
  • Long-term Stability: ≤ ±1% FS.
  • Humidity: 0-95% relative, non-condensing.
  • Response Times: Standard 1.0 s and 0.2 s.
  • Process Connection: 6 mm hose connection.
  • Electrical Connection: Spring terminals for wires and leads up to 1.5 mm² or circular connectors M12/4-pole.
  • Housing Material: ABS.
  • Dimensions: Approximately Ø 66 x 28 mm.
  • Weight: Approximately 50 grams.
  • Protection Class: IP54 with protection cover.
  • CE Conformance: EMC Directive, RoHS Directive.
Pressure Ranges: Various models available with pressure ranges from 0-100 Pa to 0-100 kPa, each with specific overload and bursting pressures.
Order Matrix: Configurable pressure ranges and output signals with supply voltage options are provided, along with electrical connection types.
Accessories: Includes Climaset® kits with hoses and pipes, duct connecting pipes, angled metal pipes, rubber grommets, and rolls of PVC or silicone hose.
Terminal Assignments: Detailed terminal assignments for 3-wire and 2-wire configurations are provided.
See more

Catalog excerpts

Beck. Differential pressure transmitter for air-1

Beck. Differential pressure transmitter for air

 Open the catalog to page 1
Beck. Differential pressure transmitter for air-2

General description Technical data The differential pressure transmitters of the 982R series are used to measure differential pressure, overpressure and vacuum. They provide one adjustable pressure range and one output signal. Applications Monitoring of gaseous, non-combustible and non-aggressive media. Possible usage areas are: • Building automation, air conditioning systems and clean room monitoring • Valve and flap control • Filter, ventilator and blower monitoring • Control of air flows Adjustable pressure range The end of the pressure range can be reduced to 50% of its factory set full scale...

 Open the catalog to page 2
Beck. Differential pressure transmitter for air-3

Pressure ranges Model Pressure range Overload capacity Bursting pressure Additional uncertainty with temperature [% FS/10K] Further pressure ranges on request. Order matrix Configurable pressure range Pressure unit Output signal and supply voltage ( 1.0 mbar) ( 2.5 mbar) ( 5.0 mbar) ( 10 mbar) ( 100 mbar) ( 250 mbar) ( 500 mbar) (1000 mbar) 3-wire, linear 3-wire, linear 3-wire, square rooted 3-wire, square rooted 2-wire, linear 2-wire, square rooted Display Electrical connection 0 ... 10 V, 4 ... 20 mA, 0 ... 10 V, 4 ... 20 mA, 4 ... 20 mA, 4 ... 20 mA, no display via spring terminals via circular...

 Open the catalog to page 3
Beck. Differential pressure transmitter for air-4

982R_data_english 7071-4 Technical data subject to change without prior notice. Dimensional Drawings Analog output signal Linear Square root 0 - 10 V 4 - 20 mA

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.