Catalog excerpts

White Paper - The production of the new industry benchmark MC6-1

Calibration White Paper WORLD-CLASS CALIBRATION SOLLTONS™

 Open the catalog to page 1
White Paper - The production of the new industry benchmark MC6-2

BEAMEX Calibration White Paper The production of the new industry be nchmark Beamex MC6 Beamex launched the MC6 advanced field calibrator and communicator in February 2012. This article takes a closer look at the production of this revolutionary product. T he processing industry is constantly going through changes and is influenced by several trends in industry, which naturally affect process calibration equipment. The starting point for the product development of the Beamex MC6 several years ago was the result of extensive market- and customer-related studies, customer feedback and analyses...

 Open the catalog to page 2
White Paper - The production of the new industry benchmark MC6-3

BEAMEX Calibration White Paper critical components related to accuracy and long-term stability. Reliability and stability A calibrator like the Beamex MC6 contains an extensive number of various components. Once all of the components have been received in house, the most critical of them are aged and temperature cycled according to R&D specifications. Thereafter, the components are soldered to the printed circuit boards. Then various tests are performed to verify the proper operation of the boards. Aging and thermal cycling improves the reliability and long-term stability of the device. The aging...

 Open the catalog to page 3
White Paper - The production of the new industry benchmark MC6-4

BEAMEX Calibration White Paper TYPICAL ”BATHTUB AGING CURVE” OF AN ELECTRONIC COMPONENT Useful life Wear out By aging the components before installation the “infant mortality” of components can be avoided. This process improves the reliability and long-term stability of the final product. Failure rate Burn in λ Time process. This assures that when the calibrator is in use, no matter what the temperature of the environment is, the calibrator will always have the best accuracy. Tailor-made according to the customer’s requirements When all of the components, parts and modules are manufactured, tested,...