INTRINSICALLY SAFE MULTIFUNCTION CALIBRATOR Made for extreme environments

Open the catalog to page 1
Brochure - Beamex MC5-IS intrinsically safe multifunction calibrator - 2

Made for extreme environments 64

Open the catalog to page 2
Brochure - Beamex MC5-IS intrinsically safe multifunction calibrator - 3

MC5-IS: designed for use in potentially explosive environments The ATEX- and IECEx- certified MC5-IS is designed for use in potentially explosive environments, such as offshore platforms, oil refineries, chemical and petrochemical plants where inflammable gases may be present. There is probably no other intrinsically safe calibrator that can outperform the MC5-IS in terms of functionality. It is a documenting, multifunction calibrator that has calibration capabilities for pressure, temperature, electrical and frequency signals. Its modular design allows configuration based on your specific...

Open the catalog to page 3
Brochure - Beamex MC5-IS intrinsically safe multifunction calibrator - 4

Additional features Accuracy guaranteed The MC5-IS is among the most accurate process calibrators available. As proof of this, each MC5-IS calibrator is delivered with a traceable, accredited calibration certificate. Made for tough use The IP65-rated robust casing, along with integrated impact protectors, makes the MC5-IS an ideal calibrator for use in wet and dusty environments subject to wide temperature variations. Modularity means versatility The MC5-IS is an extremely versatile calibrator with many different functions. The modular construction of the MC5-IS provides flexibility for the...

Open the catalog to page 4
Brochure - Beamex MC5-IS intrinsically safe multifunction calibrator - 5

Specifications General Specifications General Display Case protection IP65 (dust and water proof) Membrane protected individual keys Battery type Battery operation Charger supply Operating temperature Storage temperature Measurement sample rate Standard: 3 years for MC5-IS; 1 year for battery pack. The warranty of the MC5-IS will be extended up to 6 years if the product is calibrated on a yearly basis at Beamex’s calibration laboratory. Features of modules Feature Internal pressure modules External pressure modules Current measurement Voltage measurement Frequency measurement Pulse counting...

Open the catalog to page 5
Brochure - Beamex MC5-IS intrinsically safe multifunction calibrator - 6

Internal & external pressure modules Internal Modules1) ±1 kPa diff ±10 mbar diff ±4 iwc diff EXTERNAL MODULes Temperature coefficient 0.001 % Rdg/ °C outside 15 … 35 °C (59 … 95 °F) ± INT10mD-IS / EXT10mD-IS < ±0.002 % Span/ °C outside 15 … 35 °C (59 … 95°F) 1) The MC5-IS calibrators can hold three internal pressure modules. 2) Every internal/external pressure module’s range may also be displayed in absolute pressure if the barometric module (B) is installed. 3) ‘Accuracy’ includes hysteresis, nonlinearity, repeatability and reference standard uncertainty (k=2). 4) ‘1 Year Uncertainty’...

Open the catalog to page 6
Brochure - Beamex MC5-IS intrinsically safe multifunction calibrator - 7

Electrical Module (E) Function Pulse counting mA Sink 0 to 25 mA Temperature coefficient ±0.001 % RDG / °C outside of 15 … 35 °C (59 … 95°F) < 1) Uncertainty includes reference standard uncertainty, hysteresis, nonlinearity, repeatability and typical long-term stability for mentioned period (k=2). 2) Bias current <10 nA 3) Impedance >1 MΩ 4) Impedance < 7.5 Ω 5) MC5-IS; Impedance > 1 MΩ. Frequency measurement minimum amplitude 1 Vpp (< 10 kHz), 3 Vpp (10 … 50 kHz). Pulse counting minimum amplitude 1 Vpp (pulse length > 50 µs), 3 Vpp (pulse length 50 µs … 10 µs). Trigger level range –1 … +15...

Open the catalog to page 7
Brochure - Beamex MC5-IS intrinsically safe multifunction calibrator - 8

Thermocouple Measurement and Simulation Type Resolution 0.01 °C. With internal reference junction (module RJ) add 0.1 °C uncertainty. Other thermocouple types also available as an option. 1) Uncertainty includes reference standard uncertainty, hysteresis, nonlinearity, repeatability and typical long-term stability for mentioned period (k=2). 2) IEC 584, NIST MN 175, BS 4937, ANSI MC96.1 3) ±(0.02 % of thermovoltage + 4 µV) 4) DIN 43710 5) ASTM E 988 - 96 6) ASTM E 1751 - 95e1 Reference Junction Module (RJ) Range (°C) 1) Uncertainty includes reference standard uncertainty, hysteresis,...

Open the catalog to page 8
Brochure - Beamex MC5-IS intrinsically safe multifunction calibrator - 9

RTD Measurement and Simulation Function Measurement 1 Year Uncertainty (±) (1 Simulation 1 Year Uncertainty (±) (1 1) Uncertainty includes reference standard uncertainty, hysteresis, nonlinearity, repeatability and typical long-term stability for mentioned period (k=2). RTD types available as standard Pt50 (385) To improve uncertainty with PRT (platinum RTD) sensors, the MC5-IS includes a standard possibility that allows you to create customized PRT sensors using the Callendar van Dusen correction coefficients. The easy-to-use Beamex PRT Tool PC software is used to create the sensor and to...

Open the catalog to page 9
Brochure - Beamex MC5-IS intrinsically safe multifunction calibrator - 10

INTRINSICALLY SAFE MULTIFUNCTION CALIBRATOR The Beamex MC5-IS is ATEX- and IECEx- certified and designed for use in potentially explosive environments, such as offshore platforms, oil refineries, chemical and petrochemical plants where inflammable gases may be present. The MC5-IS is a documenting, multifunction calibrator that has calibration capabilities for pressure, temperature, electrical and frequency signals. Its modular design allows configuration based on your specific needs. Safe and robust field calibrator The ATEX- and IECEx- certified, IP65-rated MC5-IS with impact protectors...

Open the catalog to page 10

All Beamex catalogs and technical brochures

  1. MC6-Ex

    16 Pages

  2. Beamex MC2-IS

    12 Pages

  3. MCS200

    18 Pages

Archived catalogs