Beamex MC2 HAND-HELD CALIBRATOR
Open the catalog to page 1MC2 series: three different hand-held calibrators for field use Practicality in calibration. The Beamex MC2 series includes three different hand-held calibrators for field use: the MC2 pressure/electrical calibrator, the MC2 temperature/electrical calibrator and the MC2 multifunction calibrator. The MC2 is a compact and easy-to-use hand-held calibrator. It has a large graphical display, a menu-based interface and a full numerical keyboard. The MC2 represents the high, uncompromised quality standards of Beamex calibration equipment. The main features of MC2 Compact and user-friendly The MC2...
Open the catalog to page 3Internal pressure module Connection for external pressure modules Current measurement (with internal and external supply) Voltage measurement Frequency measurement Pulse counting Switch sensing Internal HART compatible 24 VDC loop supply Current generation (with internal and external supply) Voltage generation Frequency generation Pulse generation Resistance measurement / simulation FIELD EQUIPMENT | BEAMEX MC2
Open the catalog to page 4The MC2 general specifications General Specifications General Display Weight Dimensions Keyboard Battery type Charging time Charger supply Battery operation 60 mm x 60 mm (2.36" x 2.36"), 160 x 160 pixels backlit LCD 720 … 830 g (1.59 … 1.83 lbs) 215 mm (8.5") x 102 mm (4") x 49 mm (1.9") (d/w/h) Membrane keyboard Rechargeable NiMH, 4000 mAh, 3.6V DC 5 hours 100 … 240 VAC, 50-60 Hz 13 … 24 hours in measurement mode, back light off. 8 … 12 hours when sourcing an average of 12 mA to loop, with back light on. −10 … 50 °C (14 … 122°F) 0 … 35 °C (32 … 95°F) −20 to 60 °C (−4 to 140°F) 0 to 80 %...
Open the catalog to page 5Electrical measurements Frequency measurement 0.0027 … 50 000 Hz Range Temperature coefficient Specification valid from –10 to 50 °C (14 … 122°F) Input impedance Trigger level −1 … 14 V in 1 V steps and open collector inputs Minimum signal amplitude Supported units Gate period 1) Uncertainty includes reference standard uncertainty, hysteresis, non-linearity, repeatability and typical long-term stability for the mentioned period (k=2). Pulse counting 0 … 9 999 999 pulses Feature Input impedance Trigger level −1 … 14 V in 1 V steps and open collector inputs Minimum signal amplitude 2 Vpp...
Open the catalog to page 6Pressure measurement Internal Pressure Modules (IPM) Internal Module (3 kPa ±20 0.001 0.05 % RDG + 0.05 % FS mbar ±200 0.01 iwc ±80 0.01 kPa −100 to 200 0.01 0.05 % FS bar −1 to 2 0.0001 psi −14.5 to 30 0.001 kPa −100 to 2000 0.1 0.05 % FS bar −1 to 20 0.001 psi −14.5 to 300 0.01 MPa 0 … 16 0.001 0.05 % FS bar 0 … 160 0.01 psi 0 … 2400 0.1 Also enables absolute pressure measurement for the above pressure inputs. When using the barometric option, add 0.1 kPa (0.0146 psi) uncertainty for absolute pressure measurement. Temperature coefficient < ±0.001 % RDG / °C outside 15 … 35 °C. < ±0.0006 %...
Open the catalog to page 7Electrical generation, measurement and simulation mV measurement (T/C-terminals) −25 … 150 mV Range Temperature coefficient < ±0.0015 % RDG / °C outside of 18 … 28 °C < ±0.0008 % RDG / °F outside of 64.4 … 82.4°F > 10 MΩ V, mV, µV 3 / second Input impedance Supported units Display update rate mV generation (T/C-terminals) −25 … 150 mV Range Temperature coefficient < ±0.0015 % RDG / °C outside of 18 … 28 °C < ±0.0008 % RDG / °F outside of 64.4 … 82.4°F 5 mA < 5 µV/mA V, mV, µV Maximum load current Load effect Supported units Voltage generation −3 … 12 V Range Temperature coefficient <...
Open the catalog to page 8Resistance measurement 0 … 4000 Ω Range Temperature coefficient < ±0.0015 % RDG / °C outside of 18 … 28 °C < ±0.0008 % RDG / °F outside of 64.4 … 82.4°F Pulsed, bi-directional 1 mA (0..500 Ω), 0.2 mA (>500 Ω) Ω, kΩ 3 / second Measurement current Supported units Display update rate Resistance simulation 0 … 4000 Ω Range 0.04 % RDG or 30 mΩ (Whichever is greater) 0.04 % RDG or 30 mΩ (Whichever is greater) Temperature coefficient < ±0.0015 % RDG / °C outside of 18 … 28 °C < ±0.0008 % RDG / °F outside of 64.4 … 82.4°F 5 mA (0 … 650 Ω) Iexc × Rsim < 3.25 V (650 … 4 000 Ω) 1 ms Ω, kΩ Maximum...
Open the catalog to page 9Thermocouple measurement and simulation Thermocouple types available as standard Type Temperature coefficient < ±0.0015 % of thermovoltage / °C outside of 18 … 28 °C < ±0.0008 % of thermovoltage / °F outside of 64.4 … 82.4°F < ±0.0015 % of thermovoltage / °C outside of 18 … 28 °C < ±0.0008 % of thermovoltage / °F outside of 64.4 … 82.4°F Input impedance Supported units Display update rate Maximum load current Load effect Internal Reference Junction Range (°C) 1) Uncertainty includes reference standard uncertainty, hysteresis, non-linearity, repeatability and typical long-term stability...
Open the catalog to page 10RTD measurement and simulation Sensor Type Measurement 1 Year Uncertainty (±) 1 Simulation 1 Year Uncertainty (±) 1 ) 2) Temperature coefficient < ±0.0015 % of resistance / °C outside of 18 … 28 °C < ±0.0008 % of resistance / °F outside of 64.4 … 82.4 °F < ±0.0015 % of thermovoltage / °C outside of 18 … 28 °C < ±0.0008 % of thermovoltage / °F outside of 64.4 … 82.4 °F Maximum Resistance excitation current Supported units Display update rate RTD types available as standard Pt50 (385) 1) Uncertainty includes reference standard uncertainty, hysteresis, non-linearity, repeatability and...
Open the catalog to page 11All Beamex catalogs and technical brochures
-
Brochure - Software and services
44 Pages
-
MC6-Ex
16 Pages
-
Beamex smart reference p
2 Pages
-
Beamex MC2-IS
12 Pages
-
MCS200
18 Pages
-
Calibration World spring 2016
36 Pages
-
Brochure - Workshop Equipment
54 Pages
-
Brochure - Field Equipment
116 Pages
-
Brochure - Calibration Solutions
36 Pages
Archived catalogs
-
Calibration World 2-2007
24 Pages
-
Calibration World Issue 1-2007
24 Pages
-
Calibration World Issue 1-2006
24 Pages