Catalog excerpts
BIOKLARIS WATER • • • • • • • • • New PES membrane with enhanced characteristics High effective filtration area with more retention capacity Easy integrity testable in situ Steamable in situ Sanitizable and cleanable Thermowelded construction EC- listed materials for Food contact FDA-listed materials per CFR21 Increased service life to reduce filtration cost BIOKLARIS WATER filter element is designed for the treatment of water and aqueous products for human consumption. The new polyethersulfone membrane, with the high filtering surface and the specific pleating configuration, is able to guarantee improved performance in terms of service life and effluent quality. BIOKLARIS WATER cartridges can be repeatedly steam sterilized or sanitized with chemicals and can be regenerated with hot solution of sodium hydroxide. The removal of undesired microorganisms is guaranteed by the bacterial challenge test according to ASTM F 838-05. The construction is carried out in a controlled environment, with constant monitoring of all production parameters. The cartridges are 100% integrity tested and verified in production. MATERIALS OF CONSTRUCTION FOOD-SAFETY Polietersulfone (hydrophilic) Upstream supports Downstream supports Internal Core QUALITY STANDARDS External Cage Produced under a ISO 9001 certified Quality System to guarantee traceability of manufacturing records and integrity testing results. BIOKLARIS WATER filter element materials meet (EU) regulation 10/2011 and its amendments, regulations (EC) 1935/2004 AND 1895/2005. Construction materials are in compliance with FDA requirements according to CFR 21; par. 177-199. RECOMMENDED OPERATING CONDITIONS - max. continuous temperature - max. cumulative number of steam sterilization cycles ≥100 cycles at 121 °C, ≥80 cycles at 125 °C with max ∆P 0.3 bar - sanitization with hot water - sanitization with chemicals can be sanitized by usual chemical agents - recommended change out differential pressure INTEGRITY TEST DATA ABSOLUTE FILTRATION RATING IN LIQUIDS PRESSURE HOLD VALUE * TEST PRESSURE MAX. DIFFUSION FLOW VALUE IN WATER FOR 10” CARTRIDGE (ml/min) *The values are related to a test time of 5 minutes and are indicative: they depend on the ho
Open the catalog to page 1TYPICAL FLOW RATE l/h FOR 10” CARTRIDGE BACTERIAL RETENTION CODE CODE FILTRATION RATING micron * BACTERIAL RETENTION > 107 per cm2 Pseudomonas aeruginosa / Escherichia coli / Enterobacteriacee Serratia marcescens / Clostridium perfringens/ Oocycistes Criptospordium / Giardia * As per ASTM F838-05 Filtration rating 0.2 micron is able to retain 107 UFC of Brevundimonas diminuta for 10” cartridge Filtration area up to 7500 cm2 for 10” cartridge BIOKLARIS WATER—PART NUMBER ORDERING INFORMATION DOE: double open end with flat gaskets. SOE: open end with (2) O-Ring 2.222. Blind end with flat top....
Open the catalog to page 2All BEA Technologies S.p.A. catalogs and technical brochures
-
Cleartrak
2 Pages
-
Biodene
2 Pages
-
STP-R
2 Pages
-
Provent PTV
2 Pages
-
Vinotrak
2 Pages
-
Nanotrak
2 Pages
-
Qualikap QKP-P
2 Pages
-
Polyver PLV
2 Pages
-
Novatrak
2 Pages
-
Bioklaris Beer
2 Pages
-
Beamesh
2 Pages
-
Beafine
2 Pages
-
BeaFelt
2 Pages
-
Toplife TPR
2 Pages
-
Polex
2 Pages
-
OIL SEP
2 Pages
-
Mikrocell
2 Pages
-
Duplofelt
2 Pages