Bioklaris Beer

Bioklaris Beer

Bioklaris Beer

Product catalog summary
Introduction
The BIOKLARIS BEER filter is designed specifically for breweries, offering enhanced filtration capabilities while maintaining the beer's unique taste and flavor. It features a new PES membrane with improved characteristics, providing a high effective filtration area and increased retention capacity.
Specifications
  • Material: Polietersulfone membrane with polypropylene supports, core, cage, and end caps.
  • Compliance: Meets EU regulations 10/2011, 1935/2004, 1895/2005, and FDA requirements per CFR 21.
  • Construction: Thermowelded, steamable, sanitizable, and cleanable.
  • Service Life: Increased to reduce filtration costs.
Quality Standards
  • ISO 9001 certified quality system ensuring traceability and integrity testing.
  • Maximum continuous temperature: 75°C.
  • Steam sterilization cycles: ≥100 cycles at 121°C, ≥80 cycles at 125°C.
  • Sanitization: Hot water up to 90°C and chemical agents.
  • Regenerability: NaOH solution up to 3% at 85°C.
  • Maximum differential pressure: 5.0 bar at 25°C, 1.0 bar at 90°C.
Recommended Operating Conditions
  • Absolute filtration ratings: 0.45 µm (BD) and 0.65 µm (BG).
  • Pressure hold value: ≤0.12 bar.
  • Test pressure: 1.1 bar for BD, 0.8 bar for BG.
  • Flow value in water for 10” cartridge: ≤20 ml/min.
Integrity Test Data
  • Flow rate for 10” cartridge: Specific to part number and configuration.
  • Filtration area: Up to 7500 cm² for 10” cartridge.
  • Bacterial retention: Proven to retain >107 per cm² for specific microorganisms.
Ordering Information
  • End fitting codes: Various configurations available (DOE, SOE).
  • Nominal lengths: 10”, 20”, 30”, 40”.
  • Product grades: Biological grade tested and preflushed, with optional quality certification.
  • Gaskets: Standard silicone, with EPDM and Viton available on request.
Traceability and Quality Assurance
  • Each filter element is identified with a part number, lot number, serial number, and filtration rating.
  • 100% integrity tested during production and before final packaging.
See more

Catalog excerpts

Bioklaris Beer-1

BIOKLARIS BEER • • • • • • • • • New PES membrane with enhanced characteristics High effective filtration area with more retention capacity Easy integrity testable in situ Steamable in situ Sanitizable and cleanable Thermowelded construction EC- listed materials for Food contact FDA-listed materials per CFR21 Increased service life to reduce filtration cost BIOKLARIS BEER filter element has been specifically designed for breweries. Bioklaris Beer is a filter element able to guarantee the microbiological stability of the beer to be bottled; retain all the contaminants leaving the unique taste and flavor of the beer. This filter element is easily testable with a minimum flushing before use, moreover the innovative materials adopted together with a new stratification provides an enhanced life time. Bioklaris Beer is also recommended in automatic microfiltration equipments that foreseen washing and rigenerable cycles with citric acid and soda. The manufacturing is carried out in a controlled environment. The cartridges are verified in Production and are 100% integrity tested. MATERIALS OF CONSTRUCTION Polietersulfone (Highly asymmetric) Upstream supports Downstream supports Internal Core External Cage BIOKLARIS BEER filter element materials meet (EU) regulation 10/2011 and its amendments, regulations (EC) 1935/2004 AND 1895/2005. Construction materials are in compliance with FDA requirements according to CFR 21; par. 177-199. QUALITY STANDARDS Produced under a ISO 9001 certified Quality System to guarantee traceability of manufacturing records and integrity testing results. RECOMMENDED OPERATING CONDITIONS - max. continuous temperature - max. cumulative number of steam sterilization cycles ≥100 cycles at 121 °C, ≥80 cycles at 125 °C with max ∆P 0.3 bar - sanitization with hot water - sanitization with chemicals can be sanitized by usual chemical agents - recommended change out differential pressure INTEGRITY TEST DATA ABSOLUTE FILTRATION RATING IN LIQUIDS TEST PRESSURE MAX. DIFFUSION FLOW VALUE IN WATER FOR 10” CARTRIDGE (ml/min) PRESSURE HOLD VALUE * 8 cartridges of 30” *The values are related to a test time of 5 minutes and are indicative: they depend on the ho

 Open the catalog to page 1
Bioklaris Beer-2

TYPICAL FLOW RATE FOR 10” CARTRIDGE BACTERIAL RETENTION Acetobacter oeni / Pediococcus damnosus / Saccharomyces cerevisiae / Brettanomyces bruxellensis / Lactobacilius brevis Saccharomyces cerevisiae / Brettanomyces bruxellensis FILTRATION RATING micron Filtration area up to 7500 cm2 for 10” cartridge * As per ASTM F838-05 Filtration rating 0.45 micron is proven to retain 109 UFC of Serratia marcescens for 10” cartridge BIOKLARIS BEER—PART NUMBER ORDERING INFORMATION DOE: double open end with flat gaskets. SOE: open end with (2) O-Ring 2.222. Blind end with flat top. SOE: open end with (2) O-Ring...

 Open the catalog to page 2

All BEA Technologies S.p.A. catalogs and technical brochures

  1. Cleartrak

    2  Pages

  2. Biodene

    2  Pages

  3. STP-R

    2  Pages

  4. Provent PTV

    2  Pages

  5. Vinotrak

    2  Pages

  6. Nanotrak

    2  Pages

  7. Polyver PLV

    2  Pages

  8. Novatrak

    2  Pages

  9. Beamesh

    2  Pages

  10. Beafine

    2  Pages

  11. BeaFelt

    2  Pages

  12. Toplife TPR

    2  Pages

  13. Polex

    2  Pages

  14. OIL SEP

    2  Pages

  15. Mikrocell

    2  Pages

  16. Duplofelt

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.