Catalog excerpts
for connecting 2-wire submersible transmitters integrated pressure balance item The terminal box KL 2 is intended for the professional electrical connection of submersible level transmitters. Thus, it is a cost-effective alternative to our well proven aluminium terminal box KL 1. A pressure balance item is responsible for the compensation of atmospheric pressure variations. On the supply side a cable without ventilation tube can be used. Version for two independent 2 wire circuits overvoltage protection Vertical terminal clamps enable easy connection of cables inside the case. HART® connection BD SENSORS GmbH BD-Sensors-Straße 1 D - 95199 Thierstein The KL 2 with optional overvoltage protection is additionally equipped with surge arresters with a nominal discharge current of 10 kA. As a further option the KL 2 is available with a HART® connection.
Open the catalog to page 1Technical Data General specifications Number of signal lines Housing material Ingress protection Cable entries Atmospheric pressure compensation Terminal clamps Weight Optional overvoltage protection pressure balance item with PTFE filter vertical clamps for stranded and solid wires up to 2.5 mm approx. 220 g Series resistance Nominal discharge current Max. rated current ® Optional HART connection Connections Wiring diagram terminal clamp connection Interface HART Version with 2 channels, eg. LMK 307T, LMP 307T * The supply VS has to be chosen according to needs of the used transmitter. The...
Open the catalog to page 2pressure measurement 1Version for 2 independent 2 wire circuits HART® is a registered trade mark of HART Communication Foundation This dokument contains product specification; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice. BD|SENSORS GmbH BD-Sensors-Strafle 1 D - 95199 Thierstein
Open the catalog to page 3All BD|SENSORS GmbH catalogs and technical brochures
-
data sheet LMK 307 T
5 Pages
-
data sheet DMP 334i
5 Pages
-
data sheet DS 4
4 Pages
-
data sheet DS 202
5 Pages
-
data sheet DMP 335
5 Pages
-
BD|SENSORS at a glance
5 Pages
-
data sheet LMK 806
4 Pages
-
data sheet DL 01
6 Pages
-
data sheet DM 01
6 Pages
-
data sheet LMK 807
4 Pages
-
data sheet LMP 308 i
5 Pages
-
data sheet LMP 305
5 Pages
-
data sheet LMP 808
4 Pages
-
data sheet LMP 307
5 Pages
-
data sheet LMP 308
5 Pages
-
data sheet LMP 331i
5 Pages
-
date sheet LMP 307i
5 Pages
-
data sheet LMK 808
4 Pages
-
data sheet LMP 331
4 Pages
-
data sheet LMK 858
4 Pages
-
data sheet LMK 809
4 Pages
-
data sheet LMK 458
5 Pages
-
data sheet LMP 307 T
5 Pages
-
data sheet LMK 307
4 Pages
-
data sheet LMK 382
6 Pages
-
data sheet LMK 306
4 Pages
-
data sheet LMK 387
6 Pages
-
data sheet LMK 358 H
5 Pages
-
data sheet LMK 487
5 Pages
-
data sheet LMK 458 H
5 Pages
-
data sheet LMK 358
5 Pages
-
data sheet LMK 382 H
5 Pages
-
datasheet DCT 531i
5 Pages
-
data sheet DS 6
3 Pages
-
data sheet DS 200P
6 Pages
-
data sheet DCL 571
6 Pages
-
data sheet DS 350
5 Pages
-
data sheet BAROLI 02
3 Pages
-
datasheet DMP 336
4 Pages
-
data sheet DS 400
5 Pages
-
data sheet DS 201P
6 Pages
-
data sheet DS 401
5 Pages
-
data sheet DMP 331 Pi
6 Pages
-
data sheet DS 201
6 Pages
-
data sheet BAROLI 05
3 Pages
-
data sheet DS217
3 Pages
-
data sheet DS 200
6 Pages
-
data sheet DMP 457
5 Pages
-
data sheet DS210
5 Pages
-
data sheet DS 230
3 Pages
-
data sheet DMK 331
5 Pages
-
data sheet x|act i
5 Pages
-
data sheet x|act ci
5 Pages
-
data sheet DCT 531
4 Pages
-
data sheet DMP 331
6 Pages
-
data sheet XMP ci
5 Pages
-
data sheet XMP i
6 Pages
-
data sheet DMP 321
6 Pages
-
data sheet DCT 532
5 Pages
-
data sheet DCT 533
4 Pages
-
data sheet DMP i
6 Pages
-
data sheet BAROLI 02P
4 Pages
-
data sheet DS 350P
5 Pages
-
data sheet DS 5
3 Pages
-
data sheet DS 233
5 Pages
-
data sheet LMK 351
4 Pages
-
data sheet DPT 200
10 Pages
-
data sheet DMK 387
5 Pages
-
data sheet DMP 334
4 Pages
-
data sheet DMP 343
5 Pages
-
data sheet DMP 333
6 Pages
-
data sheet 351
5 Pages
-
data sheet DMK 331 P
5 Pages
-
data sheet DMP 339P
4 Pages
-
data sheet DMK 458
5 Pages
-
data sheet DMK 351 P
5 Pages
-
data sheet DMP 331 P
6 Pages
-
data sheet 26.600 G
3 Pages
-
data sheet 17.620 G
3 Pages
-
data sheet iS4
4 Pages
-
data sheet 18.605 G
3 Pages
-
data sheet 30.600 G
3 Pages
-
data sheet 18.601 G
3 Pages
-
data sheet 18.600 G
3 Pages
-
data sheet 17.609 G
3 Pages
-
data sheet 17.600G
3 Pages
-
data sheet DPT 100
4 Pages
-
data sheet DMP 339
5 Pages
-
data sheet DPS 300
5 Pages
-
data sheet DM 10
3 Pages
-
data sheet DMK 457
5 Pages
-
data sheet DMP 320
5 Pages
-
data sheet DPS 200
3 Pages
-
data sheet PA 440
3 Pages
-
data sheet DMD 331
4 Pages
-
datasheet DCT 553P
4 Pages
-
data sheet DMK456
4 Pages
-
datasheet DCT 531P
5 Pages
-
data sheet DCT 562
5 Pages
-
data sheet DCT 563
4 Pages
-
datasheet DCT 533P
4 Pages
-
data sheet DCT 561
4 Pages
-
data sheet DCT 571
5 Pages
-
data sheet LMK 387H
5 Pages
-
Data sheet DMD 831
3 Pages
-
data sheet DS 351
5 Pages
-
data sheet HU 300
5 Pages
-
DMK 351P
5 Pages
-
18.601 G
3 Pages
-
17.620 G
3 Pages
-
DCT 561
4 Pages
-
displays and evaluation devices
44 Pages
-
XMD
5 Pages
-
DPT 200
5 Pages
-
LMP 331I
4 Pages
-
KL 1terminal box aluminium
3 Pages
-
EP 500
4 Pages
-
product catalogue overall
48 Pages
-
Piezoelektrische Druckmessung
56 Pages
-
BD|SENSORS at a glance
5 Pages