DCT 561 Industrial Pressure Transmitter with RS485 Modbus RTU Ceramic Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure The DCT 561 with RS485 interface uses the communication protocol Modbus RTU which has found the way in industrial communication as an open protocol. The Modbus protocol is based on a master slave architecture with which up to 247 slaves can be questioned by a master – the data will transfer in binary form. from 0 ... 600 mbar up to 0 ... 600 bar Output signal RS485 with Modbus RTU protocol Special characteristic ► good thermal behaviour The sensor technology of the DCT 561 is the same as those of the proven pressure transmitter DMK 331, whereby the DCT 561 is suitable for pasty, polluted and aggressive media as well as for low-pressure oxygen applications. good long term stability The modular concept of the pressure transmitter allows customized electrical or mechanical connections, so it is easy to adapt the DCT 561 to different conditions on-site. pressure port G 1/2" open port PVDF for aggressive media (up to 60 bar) oxygen application Preferred areas of use are Plant and machine engineering Environmental engineering (water - sewage - recycling) Medical technology BD SENSORS GmbH BD-Sensors-Straße 1 D - 95199 Thierstein www.bdsensors.com info@bdse
Open the catalog to page 1DCT 561 Industrial Pressure Transmitter with RS485 Modbus RTU Technical Data Input pressure range 1 Nominal pressure gauge Nominal pressure abs. Overpressure Burst pressure ≥ Nominal pressure gauge / abs. Overpressure Burst pressure ≥ Vacuum resistance RS485 with Modbus RTU protocol VS = 9 … 32 VDC ≤ ± 0.5 % FSO ≤ ± 0.1 % FSO / year at reference conditions 500 Hz 500 msec accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability) for pressure port of PVDF the minimum temperature is -30 °C Electrical protection Short-circuit protection Reverse polarity...
Open the catalog to page 2Electrical connections (dimensions in mm) DCT 561Industrial Pressure Transmitter with RS485 Modbus RTU Technical DataPin configurationstandard option cable outlet with PVC cable (IP 67) 6 on request 6 standard: 2 m PVC cable without ventilation tube (permissible temperature: -5... 70°C) 7different cable types and lengths available, permissible temperature depends on kind of cable Mechanical connections (dimensions in mm) o metric threads and other versions on request
Open the catalog to page 3Ordering code DCT 561 pressure measurement Mechanical connection FKM EPDM 4 customer Pressure port stainless steel 1.4404 (316L) PVDF 5 customer Special version standard oxygen application 6 customer 1 standard: 2 m PVC cable without ventilation tube (permissible temperature: -5 ... 70 °C); others on request 2 code TR0 = PVC cable, cable with ventilation tube available in different types and lengths 3 metric threads and others on request 4 possible for nominal pressure range PN < 160 bar 5 PVDF only with G1/2" DIN 3852 open pressure port (up to 60 bar), minimum permissible temperature is -30...
Open the catalog to page 44 Pages
5 Pages
4 Pages
5 Pages
10 Pages
4 Pages
5 Pages
5 Pages
5 Pages
5 Pages
6 Pages
6 Pages
5 Pages
6 Pages
6 Pages
6 Pages
6 Pages
4 Pages
6 Pages
5 Pages
5 Pages
5 Pages
4 Pages
6 Pages
6 Pages
4 Pages
5 Pages
5 Pages
4 Pages
5 Pages
5 Pages
5 Pages
4 Pages
4 Pages
4 Pages
5 Pages
5 Pages
4 Pages
6 Pages
4 Pages
6 Pages
5 Pages
5 Pages
5 Pages
5 Pages
5 Pages
5 Pages
3 Pages
6 Pages
5 Pages
3 Pages
4 Pages
5 Pages
5 Pages
3 Pages
3 Pages
5 Pages
3 Pages
5 Pages
5 Pages
5 Pages
4 Pages
6 Pages
5 Pages
6 Pages
6 Pages
5 Pages
4 Pages
4 Pages
5 Pages
3 Pages
5 Pages
4 Pages
5 Pages
6 Pages
5 Pages
5 Pages
4 Pages
5 Pages
5 Pages
3 Pages
3 Pages
4 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
4 Pages
5 Pages
5 Pages
3 Pages
5 Pages
5 Pages
3 Pages
3 Pages
4 Pages
4 Pages
4 Pages
5 Pages
5 Pages
4 Pages
4 Pages
4 Pages
5 Pages
5 Pages
3 Pages
5 Pages
5 Pages
3 Pages
3 Pages
44 Pages
5 Pages
5 Pages
4 Pages
3 Pages
3 Pages
4 Pages
48 Pages
56 Pages
5 Pages