1. Catalogs
  2. BD|SENSORS GmbH
  3. data sheet x|act ci

data sheet x|act ci

data sheet x|act ci

data sheet x|act ci

Product catalog summary
Overview: The x|act ci is a precision pressure transmitter designed for the food, beverage, pharmaceutical, and biotechnology industries. It features a ceramic sensor with high accuracy and media stability, suitable for measuring gases, steam, and fluids.
Specifications: The transmitter offers a nominal pressure range from 0 to 160 mbar up to 0 to 20 bar, with an accuracy of 0.1% FSO according to IEC 60770. It supports a 2-wire output signal of 4 to 20 mA, with other options available upon request. The device is capable of a turn-down ratio of 1:5 and includes a hygienic version with a flush-mounted, capacitive ceramic sensor.
Optional Features: Explosion protection with intrinsic safety (ia) and HART® communication are available as optional features.
Performance: The transmitter maintains an accuracy of ≤ ± 0.2% FSO for pressures below 1 bar and ≤ ± 0.1% FSO for pressures above 1 bar. It has a long-term stability of ≤ ± 0.1% FSO per year and a response time of 200 milliseconds.
Environmental and Mechanical Stability: The device operates within a medium temperature range of -25 to 125°C and an environmental range of -20 to 70°C. It is protected against short-circuit and reverse polarity, with electromagnetic compatibility according to EN 61326. It withstands vibrations up to 5 g RMS and shocks up to 100 g.
Materials and Construction: The pressure port is made from stainless steel 1.4404 (316L), with optional PVDF for certain connections. The housing is stainless steel 1.4301 (304), and the diaphragm is made from 99.9% Al2O3 ceramic.
Explosion Protection: The device is approved for use in hazardous areas with specific ATEX certifications, suitable for zones 0/1 and 20.
Miscellaneous: The x|act ci includes an LC display with a 5-digit main display and a 52-segment bargraph. It has an ingress protection rating of IP 67 and a minimum weight of 400 g. The operational life is rated at 100 million load cycles.
Applications: Ideal for use in food and beverage, chemical and petrochemical industries, and laboratory techniques, particularly with viscous and pasty media.
See more

Catalog excerpts

data sheet x|act ci-1

xact ci Precision Pressure Transmitter for Food / Beverage, Pharmaceutical Industry and Biotechnology Ceramic Sensor accuracy according to IEC 60770: 0.1 % FSO The precise pressure transmitter x|act ci measures the pressure of gases, steam and fluids. The special-developed capacitive ceramic sensor for this transmitter, which can optionally be delivered in pure ceramic, has a high overpressure capability and excellent media stability. Nominal pressure from 0 ... 160 mbar up to 0... 20 bar Output signals 2-wire: 4 ... 20 mA others on request Several process connections e.g. inch thread or hygienic versions like Varivent®, dairy pipe or Clamp are available. The robust stainless steel globe housing has a high ingress protection IP 67 and all characteristics for a residue-free and antibacterial cleaning. hygienic version flush mounted, capacitive ceramic sensor several process connections (inch thread, Clamp, etc.) with integrated display and operating module Chemical and petrochemical industry Laboratory techniques explosion protection intrinsic safety (ia) Viscous and pasty media BD SENSORS GmbH BD-Sensors-Straße 1 D - 95199 Thierstein

 Open the catalog to page 1
data sheet x|act ci-2

xact ci Precision Pressure Transmitter Pressure ranges 1 Nominal pressure gauge Overpressure Permissible vacuum Technical Data On customer request we adjust the devices by software on the required pressure ranges (within the turn-down-possibility; starting at 0.02 bar). Output signal / Supply 2-wire: 4 ... 20 mA standard: options: analogue signal intrinsic safety (ia) intrinsic safety (ia) with HART®-communication Current consumption Performance ≤ ± 0.2 % FSO nominal pressure < 1 bar: nominal pressure ≥ 1 bar: ≤ ± 0.1 % FSO for nominal pressure ranges: ≤ ± (0.2 + (TD-1) x 0.02) % FSO from 0.16...

 Open the catalog to page 2
data sheet x|act ci-3

xact ci Precision Pressure Transmitter Miscellaneous Display Technical Data LC-display, visible range 32.5 x 22.5 mm; 5-digit 7-segment main display, digit height 8 mm, range of indication ±9999; 8-digit 14-segment additional display, digit height 5 mm; 52-segement bargraph; accuracy 0.1% ± 1 digit IP 67 any min. 400 g (depending on mechanical connection) 100 million load cycles EMC Directive: 2014/30/EU 2014/34/EU Ingress protection Installation position Weight Operational life CE-conformity ATEX Directive Wiring diagram Pin configuration Electrical connections Supply + Supply – Shield Electrical...

 Open the catalog to page 3
data sheet x|act ci-4

xact ci Precision Pressure Transmitter Technical Data © 2023 BD|SENSORS GmbH – The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. Inch thread flush diaphragm ∅26.5 dimensions in mm size DN 40 DN 50 C 56 68.5 cup nut for dairy pipe or mounting flange for DRD is included in the delivery (already pre-assembled) HART® is a registered trademark of HART Communication Foundation; Varivent® is a trademark of GEA Tuchenhagen GmbH; Windows® is a registered trademark of Microsoft...

 Open the catalog to page 4
data sheet x|act ci-5

Ordering code x|act ci x|act ci Input Design Output side display 45° display 4 … 20 mA / 2-wire intrinsic safety (ia) 4 … 20 mA / 2-wire intrinsic safety (ia) 4 … 20 mA / 2-wire with HART®-communication customer Electrical connection male plug M12x1 (4-pin) customer Mechanical connection G 1 1/2" DIN flush (DIN 3852) Clamp DN 32 / 1 1/2" (DIN 32676) Clamp DN 50 / 2" (DIN 32676) dairy pipe DN 40 (DIN 11851) dairy pipe DN 50 (DIN 11851) Varivent® DN 40/50 flange DN 25 / PN 40 (DIN 2501) flange DN 50 / PN 40 (DIN 2501) flange DN 80 / PN 16 (DIN 2501) DRD Ø 65 mm customer Diaphragm ceramics Al2O3...

 Open the catalog to page 5

All BD|SENSORS GmbH catalogs and technical brochures

  1. DMK 351P

    5  Pages

  2. 18.601 G

    3  Pages

  3. 17.620 G

    3  Pages

  4. DCT 561

    4  Pages

  5. XMD

    5  Pages

  6. DPT 200

    5  Pages

  7. LMP 331I

    4  Pages

  8. EP 500

    4  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.