data sheet LMP 331 - 1

LMP 331 Screw-In Transmitter Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.1 % FSO Nominal pressure The screw-in transmitter LMP 331 has been designed for continuous level measurement and is characterized by an excellent performance and a robust construction. The modular construction allows the user the highest possible flexibility in the adaption of LMP 331. from 0 ... 100 mbar up to 0 ... 40 bar Output signals 2-wire: 4 ... 20 mA 3-wire: 0 … 20 mA / 0 … 10 V others on request Optional features like e.g. an intrinsically safe version or a functionally safe version (SIL 2) increase the advantages when launching and realizing projects for plants and systems. pressure port G 3/4" flush excellent accuracy small thermal effect excellent long term stability Preferred areas of use are Plant and machine engineering Optional versions Energy industry ► IS-version: Ex ia = intrinsically safe for gases and dusts different electrical connections customer specific versions e. g. special pressure ranges BD SENSORS GmbH BD-Sensors-Straße 1 D - 95199 Thierstein Environmental engineering (water – sewage – recycling)

Open the catalog to page 1
data sheet LMP 331 - 2

LMP 331 Stainless Steel Screw-In Transmitter Input pressure range Nominal pressure gauge [bar] 0.10 0.16 0.25 0.40 0.60 1 Level [mH2O] 1 1.6 2.5 4 6 10 Overpressure [bar] 0.5 1 1 2 5 5 1.5 1.5 3 7.5 7.5 Burst pressure ≥ [bar] 1.5 Vacuum resistance pN ≥ 1 bar: unlimited vacuum resistance Output signal / Supply Standard Option IS-version Options 3-wire Performance Accuracy1 Permissible load Influence effects Long term stability Response time 2 1 2 Technical Data nominal pressure < 0.4 bar: ≤ ± 0.5 % FSO nominal pressure ≥ 0.4 bar: ≤ ± 0.35 % FSO option 1: nominal pressure ≥ 0.4 bar: ≤ ± 0.25...

Open the catalog to page 2
data sheet LMP 331 - 3

LMP 331 Stainless Steel Screw-In Transmitter Technical Data Supply + Supply – Signal + (only for 3-wire) Shield Electrical connections compact field housing IN + IN – OUT + cable colours (IEC 60757) WH (white) BN (brown) GN (green) GNYE (green-yellow) Electrical connections (dimensions in mm) standard cable outlet with PVC cable (IP 67) 5 cable outlet, cable with ventilation tube (IP 68) 6 compact field housing (IP 67) standard: 2 m PVC cable (without ventilation tube, permissible temperature: -5 ... 70 °C) different cable types and lengths available, permissible temperature depends on kind...

Open the catalog to page 3
data sheet LMP 331 - 4

Pressure port stainless steel 1.4435 (316L) customer Electrical connection male and female plug ISO 4400 male plug Binder series 723 (5-pin) cable outlet with PVC cable (IP67) cable outlet, cable with ventilation tube (IP68) male plug M12x1 (4-pin) / metal compact field housing stainless steel 1.4301 (304) customer Accuracy standard for p N ≥ 0.4 bar: 0.35 % FSO standard for p N < 0.4 bar: 0.50 % FSO option 1 for pN ≥ 0.4 bar: 0.25 % FSO option 2: 0.10 % FSO customer Special version standard customer stainless steel 1.4404 (316L) customer code TR0 = PVC cable, cable with ventilation tube...