data sheet LMP 307
5Pages

{{requestButtons}}

Catalog excerpts

data sheet LMP 307 - 1

LMP 307 Stainless Steel Probe Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.35 % FSO options: 0.25 % / 0.1 % FSO Nominal pressure The stainless steel probe LMP 307 is designed for continuous level measurement in water and clean or lightly polluted fluids. Basic element is a high quality stainless steel sensor with high requirements for exact measurement with good long term stability. small thermal effect high accuracy good long term stability IS-version Ex ia = intrinsically safe for gas and dust SIL 2 (Safety Integrity Level) drinking water certificate according to DVGW and KTW different kinds of cables and elastomers petrol-version welded pressure sensor and housing Water / filtrated sewage drinking water systems ground water level measurement rain spillway basins pump and booster stations level measurement in containers water treatment plants water recycling mounting with stainless steel pipe BD SENSORS GmbH BD-Sensors-Straße 1 D - 95199 Thierstein Fuel and oil fuel storage tank farms

Open the catalog to page 1
data sheet LMP 307 - 2

LMP 307 Stainless Steel Probe Technical Data Input pressure range Nominal pressure gauge [bar] 0.1 Level [mH2O] 1 Overpressure [bar] 0.5 Burst pressure ≥ [bar] 1.5 Max. ambient pressure (housing): 40 bar Output signal / Supply Standard Option IS-version Options 3-wire Performance Accuracy 1 Permissible load Influence effects Long term stability Response time 1 nominal pressure < 0.4 bar: ≤ ± 0.5 % FSO nominal pressure ≥ 0.4 bar: ≤ ± 0.35 % FSO option 1: nominal pressure ≥ 0.4 bar: ≤ ± 0.25 % FSO option 2: for all nominal pressures: ≤ ± 0.1 % FSO current 2-wire: Rmax = [(VS – VS min) / 0.02...

Open the catalog to page 2
data sheet LMP 307 - 3

LMP 307 Stainless Steel Probe Technical Data Miscellaneous Option SIL 2 version 6 Drinking water certificate 7 according to IEC 61508 / IEC 61511 according to DVGW W 270 and UBA KTW (with order the indication "with drinking water certificate" is necessary) signal output current: max. 25 mA signal output voltage: max. 7 mA approx. 200 g (without cable) IP 68 EMC Directive: 2014/30/EU 2014/34/EU Current consumption Weight Ingress protection CE-conformity ATEX Directive 6 7 not in combination with the accuracy 0.1 %, only for 4...20 mA / 2-wire only possible with EPDM seal in combination with...

Open the catalog to page 3
data sheet LMP 307 - 4

LMP 307 Stainless Steel Probe Technical Data Accessories cable gland M16x1.5 with seal insert (for cable-∅ 4 ... 11 mm) size b D d2 d4 f k n Technical data Suitable for all probes Flange material stainless steel 1.4404 (316L) Material of cable gland standard: brass, nickel plated on request: stainless steel 1.4305 (303); plastic Seal insert material: TPE (ingress protection IP 68) Hole pattern according to DIN 2507 Weight Ordering type Ordering code DN25 / PN40 with cable gland brass, nickel plated ZMF2540 1.4 kg DN50 / PN40 with cable gland brass, nickel plated ZMF5040 3.2 kg DN80 / PN16...

Open the catalog to page 4
data sheet LMP 307 - 5

Accuracy standard for p N ≥ 0.4 bar standard for p N < 0.4 bar option 1 for p N ≥ 0.4 bar option 2 0.35 % FSO 0.5 % FSO 0.25 % FSO 0.1 % FSO customer Electrical connection / cable length PVC-cable (grey, Ø 7.4 mm) 3m 5m 10 m 15 m special length in m consult consult consult TPE-U-cable (blue, Ø 7.4 mm) special length in m standard prepared for mounting with stainless steel customer Special version FEP-cable (black, Ø 7.4 mm) 5m 10 m special length in m PUR-cable (black, Ø 7.4 mm) 3m 5m 10 m 15 m special length in m DVGW/KTW: petrol-version: stainless steel 1.4435 (316L) customer FKM EPDM...

Open the catalog to page 5