LMK 458H Probe with HART®-communication for Marine and Offshore Ceramic Sensor Nominal pressure The hydrostatic probe LMK 458H has been developed for measuring level in service and storage tanks and is certificated for shipbuilding and offshore applications. from 0 ... 60 cmH2O up to 0 ... 200 mH2O Output signals 2-wire: 4 ... 20 mA others on request A permissible operating temperature up to 85°C and the possibility to use the device in intrinsic safe areas enable to measure the pressure of various fluids under extreme conditions. The basis for the LMK 458H is a self-developed capacitive ceramic sensor element, which offers a high overload resistance and medium compatibility. shipping approvals acc. to: Lloyd´s Register (LR), Det Norske Veritas (DNV), China Classification Society (CCS), American Bureau of Shipping (ABS) HART® communication (setting of offset, span and damping) Water drinking water abstraction desalinization plant high overpressure resistance high long-term stability IS-version Ex ia = intrinsically safe for gas and dust different housing materials (stainless steel, CuNiFe) screw-in and flange version Shipbuilding / Offshore ballast tanks draught monitoring level measurement in ballast and storage tanks accessories e. g. assembling and probe flange, mounting clamp BD SENSORS GmbH BD-Sensors-Straße 1 D - 95199 Thierstein
Open the catalog to page 1LMK 458H Probe for Marine and Offshore Pressure ranges Nominal pressure gauge 1 [bar] Level [mH2O] Overpressure [bar] Technical Data Max. ambient pressure (housing): 40 bar 1 on customer request we adjust the devices by software on the required pressure ranges, within the turn-down possibility (starting at 0.02 bar) Output signal / Supply Standard Option IS-version Performance Accuracy 2 Permissible load Long term stability Influence effects Turn-on time Mean response time Max. response time Adjustability 2 3 with HART communication with HART communication ≤ ± 0.2 % FSO TDmax = 1:10 ≤ ±...
Open the catalog to page 2LMK 458H Probe for Marine and Offshore Technical Data Wiring diagram 2-wire-system (current) HART® supply + Pin configuration Electrical connection Supply VS + Supply VS – Shield Dimensions for housing in stainless steel and CuNiFe (mm / in) probe screw-in version cable colours (IEC 60757) WH (white) BN (brown) GNYE (green-yellow) prepared for mounting with stainless steel pipe flange version transmitter flange is not part of supply and has to be ordered separately HART® is a registered trade mark of HART Communication Foundation; Windows® is a registered trade mark of Microsoft Corporation
Open the catalog to page 3LMK 458H Probe for Marine and Offshore Technical Data Accessories Transmitter flange for flange version Technical data Suitable for Flange material Hole pattern Ordering type Transmitter flange DN25 / PN40 Transmitter flange DN50 / PN40 Transmitter flange DN80 / PN16 LMK 382, LMK 382H, LMK 458, LMK 458H stainless steel 1.4404 (316L) according to DIN 2507 Ordering code ZSF2540 ZSF5040 ZSF8016 Mounting flange with cable gland cable gland M16x1.5 with seal insert (for cable-∅ 4 ... 11 mm) size b D d2 d4 f k n Technical data Suitable for all probes Flange material stainless steel 1.4404 (316L)...
Open the catalog to page 4probe flange version screw-in version Electrical connection TPE-U-cable (blue, Ø 7.4 mm) customer Accuracy pN ≥ 1 bar: 0.1 % FSO pN < 1 bar: 0.2 % FSO customer Cable length in m Special version standard prepared for mounting with stainless steel pipe customer HART®-communication 4 … 20 mA / 2-wire HART®-communication intrinsic safety 4 … 20 mA / 2-wire customer FKM EPDM FFKM customer stainless steel 1.4404 (316L) copper-nickel-alloy (CuNi10Fe1Mn) customer min. permissible temperature from -15°C shielded cable with integrated ventilation tube for atmospheric reference mounting accessories...
Open the catalog to page 5All BD|SENSORS GmbH catalogs and technical brochures
-
data sheet LMK 307 T
5 Pages
-
data sheet DMP 334i
5 Pages
-
data sheet DS 4
4 Pages
-
data sheet DS 202
5 Pages
-
data sheet DMP 335
5 Pages
-
BD|SENSORS at a glance
5 Pages
-
data sheet LMK 806
4 Pages
-
data sheet DL 01
6 Pages
-
data sheet DM 01
6 Pages
-
data sheet LMK 807
4 Pages
-
data sheet LMP 308 i
5 Pages
-
data sheet LMP 305
5 Pages
-
data sheet LMP 808
4 Pages
-
data sheet LMP 307
5 Pages
-
data sheet LMP 308
5 Pages
-
data sheet LMP 331i
5 Pages
-
date sheet LMP 307i
5 Pages
-
data sheet LMK 808
4 Pages
-
data sheet LMP 331
4 Pages
-
data sheet LMK 858
4 Pages
-
data sheet LMK 809
4 Pages
-
data sheet LMK 458
5 Pages
-
data sheet LMP 307 T
5 Pages
-
data sheet LMK 307
4 Pages
-
data sheet LMK 382
6 Pages
-
data sheet LMK 306
4 Pages
-
data sheet LMK 387
6 Pages
-
data sheet LMK 358 H
5 Pages
-
data sheet LMK 487
5 Pages
-
data sheet LMK 358
5 Pages
-
data sheet LMK 382 H
5 Pages
-
datasheet DCT 531i
5 Pages
-
data sheet DS 6
3 Pages
-
data sheet DS 200P
6 Pages
-
data sheet DCL 571
6 Pages
-
data sheet DS 350
5 Pages
-
data sheet BAROLI 02
3 Pages
-
datasheet DMP 336
4 Pages
-
data sheet DS 400
5 Pages
-
data sheet DS 201P
6 Pages
-
data sheet DS 401
5 Pages
-
data sheet DMP 331 Pi
6 Pages
-
data sheet DS 201
6 Pages
-
data sheet BAROLI 05
3 Pages
-
data sheet DS217
3 Pages
-
data sheet DS 200
6 Pages
-
data sheet DMP 457
5 Pages
-
data sheet DS210
5 Pages
-
data sheet DS 230
3 Pages
-
data sheet DMK 331
5 Pages
-
data sheet x|act i
5 Pages
-
data sheet x|act ci
5 Pages
-
data sheet DCT 531
4 Pages
-
data sheet DMP 331
6 Pages
-
data sheet XMP ci
5 Pages
-
data sheet XMP i
6 Pages
-
data sheet DMP 321
6 Pages
-
data sheet DCT 532
5 Pages
-
data sheet DCT 533
4 Pages
-
data sheet DMP i
6 Pages
-
data sheet BAROLI 02P
4 Pages
-
data sheet DS 350P
5 Pages
-
data sheet DS 5
3 Pages
-
data sheet DS 233
5 Pages
-
data sheet LMK 351
4 Pages
-
data sheet DPT 200
10 Pages
-
data sheet DMK 387
5 Pages
-
data sheet DMP 334
4 Pages
-
data sheet DMP 343
5 Pages
-
data sheet DMP 333
6 Pages
-
data sheet 351
5 Pages
-
data sheet DMK 331 P
5 Pages
-
data sheet DMP 339P
4 Pages
-
data sheet DMK 458
5 Pages
-
data sheet DMK 351 P
5 Pages
-
data sheet DMP 331 P
6 Pages
-
data sheet 26.600 G
3 Pages
-
data sheet 17.620 G
3 Pages
-
data sheet iS4
4 Pages
-
data sheet 18.605 G
3 Pages
-
data sheet 30.600 G
3 Pages
-
data sheet 18.601 G
3 Pages
-
data sheet 18.600 G
3 Pages
-
data sheet 17.609 G
3 Pages
-
data sheet 17.600G
3 Pages
-
data sheet DPT 100
4 Pages
-
data sheet DMP 339
5 Pages
-
data sheet DPS 300
5 Pages
-
data sheet DM 10
3 Pages
-
data sheet DMK 457
5 Pages
-
data sheet DMP 320
5 Pages
-
data sheet DPS 200
3 Pages
-
data sheet PA 440
3 Pages
-
data sheet DMD 331
4 Pages
-
datasheet DCT 553P
4 Pages
-
data sheet DMK456
4 Pages
-
datasheet DCT 531P
5 Pages
-
data sheet DCT 562
5 Pages
-
data sheet DCT 563
4 Pages
-
datasheet DCT 533P
4 Pages
-
data sheet DCT 561
4 Pages
-
data sheet DCT 571
5 Pages
-
data sheet LMK 387H
5 Pages
-
Data sheet DMD 831
3 Pages
-
data sheet DS 351
5 Pages
-
data sheet HU 300
5 Pages
-
DMK 351P
5 Pages
-
18.601 G
3 Pages
-
17.620 G
3 Pages
-
DCT 561
4 Pages
-
displays and evaluation devices
44 Pages
-
XMD
5 Pages
-
DPT 200
5 Pages
-
LMP 331I
4 Pages
-
KL 2terminal box plastics
3 Pages
-
KL 1terminal box aluminium
3 Pages
-
EP 500
4 Pages
-
product catalogue overall
48 Pages
-
Piezoelektrische Druckmessung
56 Pages
-
BD|SENSORS at a glance
5 Pages