data sheet DS 5

data sheet DS 5

data sheet DS 5

Product catalog summary
Overview: The DS 5 is an electronic OEM pressure switch designed for heavy-duty applications such as mobile hydraulics, presses, and oxygen applications. It features a stainless steel sensor and offers configurable pressure ranges from 0 to 600 bar.
Specifications:
  • Pressure Range: Nominal pressure ranges from 16 to 600 bar with overpressure limits up to 1200 bar and burst pressure up to 2000 bar.
  • Supply Voltage: 12 to 30 VDC with a maximum current consumption of 14 mA.
  • Contacts: Available with 1 or 2 PNP contacts, supporting a maximum switching performance of 300 mA.
  • Accuracy: Contact accuracy is ≤ ± 1% FSO, with repeatability ≤ ± 0.2% FSO.
  • Thermal Effects: Thermal error is ≤ ± 0.2% FSO/10 K within a compensated range of -20 to 80°C.
Electrical and Mechanical Features:
  • Protection: Includes permanent short-circuit protection and reverse polarity protection.
  • Compatibility: Complies with EN 61326 for electromagnetic compatibility.
  • Stability: Vibration resistance up to 10 g RMS and shock resistance up to 100 g.
  • Materials: Constructed with stainless steel for the pressure port, housing, and sensor.
Additional Features:
  • Ingress Protection: Rated at IP 67.
  • Operational Life: Exceeds 100 million load cycles.
  • CE Conformity: Complies with EMC Directive 2014/30/EU and Pressure Equipment Directive 2014/68/EU for devices with overpressure > 200 bar.
Configuration and Ordering: The DS 5 can be configured using a programming kit or device. It offers various mechanical connections and is available in oil and grease-free versions for specific applications.
See more

Catalog excerpts

data sheet DS 5-1

DS 5 Electronic OEM Pressure Switch Heavy Duty Applications: ► ► ► mobile hydraulics presses oxygen application stainless steel sensor, welded nominal pressure ranges from 0 … 16 bar up to 0 … 600 bar configurable via PC or programming device P6 optionally: oil and grease free version Technical Data Input pressure range Nominal pressure gauge Overpressure (static) Burst pressure ≥ Supply Supply voltage Current consumption Contacts Number Type Switching performance Accuracy of contacts Repeatability Minimum hysteresis of contacts Status indication Switching function 1 Switching mode 1 Switch on point 1 Switch off point 1 Switch on / switch off delay 1 Switching frequency Switching cycles 1 VS = 12 ... 30 VDC max. 14 mA (without contacts) standard: 1 option: 2 PNP max. 300 mA, short-circuit proof IEC 60770: ≤ ± 1 % FSO ≤ ± 0.2 % FSO ≤ ± 0.5 % FSO SP 1: green SP 2: yellow standard: n/o option: n/c standard: hysteresis mode option: window mode standard: factory setting 80 % FSO others: specify on order; adjustable range 5 ... 100 % FSO standard: factory setting 75 % FSO others: specify on order; adjustable range 5 ... 100 % FSO standard: off others: specify on order, adjustable range from 10 msec up to 90 sec (step 10 msec) 200 Hz (without switching delay) > 100 x 106 Parameters can be programmed by customer either with the programming kit CIS-G or with the programming device P6 (available as accessories). Thermal effects (Offset and Span) / Permissible temperatures Thermal error ≤ ± 0.2 % FSO / 10 K Permissible temperatures medium: -40 ... 125 °C BD SENSORS GmbH BD-Sensors-Straße 1 D - 95199 Thierstein in compensated range -20 ... 80 °C electronics / environment / storage: -40 ... 85 °C

 Open the catalog to page 1
data sheet DS 5-2

DS 5 Electronic OEM Pressure Switch permanent no damage, but also no function emission and immunity according to EN 61326 10 g RMS (20 ... 2000 Hz) 100 g / 11 msec stainless steel 1.4404 (316L) stainless steel 1.4305 (303) FKM none (welded) stainless steel 1.4548 (17-4PH) pressure port, seal, sensor oxygen application approx. 90 g any 100 million load cycles IP 67 EMC Directive: 2014/30/EU Pressure Equipment Directive: 2014/68/EU (module A) 2 This directive is only valid for devices with maximum permissible overpressure > 200 bar Wiring diagrams 1 contact Pin configuration Electrical connection...

 Open the catalog to page 2
data sheet DS 5-3

Pressure Input 1 contact 2 contacts Electrical connection M12x1 (4-pin), metal customer Mechanical connection / Seal G1/4" DIN 3852 / on pressure port: FKM 1/4" NPT / without R1/4" / without 7/16"-20 UNF female thread / without customer Setting code BD SENSORS standard setting according to customer Special version standard oxygen application oil and grease free customer Parameters can be programmed by customer either with the programming kit CIS-G or with the programming device P6 (available as accessories). © 2021 BD|SENSORS GmbH - The specifications given in this document represent the state...

 Open the catalog to page 3

All BD|SENSORS GmbH catalogs and technical brochures

  1. DMK 351P

    5  Pages

  2. 18.601 G

    3  Pages

  3. 17.620 G

    3  Pages

  4. DCT 561

    4  Pages

  5. XMD

    5  Pages

  6. DPT 200

    5  Pages

  7. LMP 331I

    4  Pages

  8. EP 500

    4  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.