data sheet DS 400 - 1

DS 400 Intelligent Electronic Pressure Switch Stainless Steel Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO Nominal pressure The electronic pressure switch DS 400 is the successful combination of intelligent pressure switch digital display Contacts 1 or 2 independent PNP contacts, freely configurable and has been specially designed for numerous applications in various industrial sectors. Analogue output As standard the DS 400 offers a PNP contact and a display module, which is mounted rotable in the globe housing. Additional optional versions like e.g. an intrinsically safe version, a second contact and an analogue output complete the profile. 2-wire: 4 ... 20 mA 3-wire: 4 … 20 mA others on request Special characteristics ► indication of measured values on a 4-digit LED display rotatable and configurable display module Preferred areas of use are Plant and machine engineering IS-version Ex ia = intrinsically safe for gases and dust welded pressure sensor customer specific versions BD SENSORS GmbH BD-Sensors-Straße 1 D - 95199 Thierstein Environmental engineering (water – sewage – recycling)

Open the catalog to page 1
data sheet DS 400 - 2

DS 400 Electronic Pressure Switch Input pressure range Nominal pressure gauge Nominal pressure absolute Overpressure Burst pressure Nominal pressure gauge / absolute Overpressure Burst pressure Vacuum resistance Contact 1 Number, type Max. switching current Accuracy of contacts 2 Repeatability Switching frequency Switching cycles Delay time 1 Technical Data standard: 1 PNP contact option: 2 independent PNP contacts contact rating 125 mA, short-circuit resistant; Vswitch = VS − 2V ≤ ± 0.25 % FSO ≤ ± 0.1 % FSO 2-wire: max. 10 Hz 3-wire: 50 Hz > 100 x 106 0 ... 100 sec with IS-protection max....

Open the catalog to page 2
data sheet DS 400 - 3

DS 400 Electronic Pressure Switch Technical Data Explosion protection (only for 4 … 20 mA / 2-wire) Approval AX14-DS 400 IBExU 06 ATEX 1050 X zone 0: II 1G Ex ia IIC T4 Ga zone 20: II 1D Ex ia IIIC T135 °C Da Safety techn. maximum values Ui = 28 V, Ii = 93 mA, Pi = 660 mW, Ci ≈ 0 pF, Li ≈ 0 µH Max. switching current 5 70 mA Permissible temperatures for in zone 0: -20 ... 60 °C with patm 0.8 bar up to 1.1 bar environment in zone 1 or higher: -25 ... 70 °C 5 the real switching current in the application depends on the power supply unit Miscellaneous Display 4-digit, 7-segment-LED display;...

Open the catalog to page 3
data sheet DS 400 - 4

DS 400 Electronic Pressure Switch Technical Data * for nominal pressure pN > 400 bar increases the length of devices without IS-protection by 19 mm Mechanical connections (dimensions mm / in)  metric threads and other versions on request www.bdsensors.de info@bdsensors.de © 2023 BD|SENSORS GmbH – The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials.

Open the catalog to page 4
data sheet DS 400 - 5

side display 45° display Analogue output without 4 … 20 mA / 2-wire 4 … 20 mA / 3-wire, adjustable intrinsic safety 4 … 20 mA / 2-wire customer Contact 1 contact 2 contacts Accuracy standard for p N ≥ 0.4 bar 0.35 % standard for p N< 0.4 bar 0.50 % option for pN ≥ 0.4 bar 0.25 % customer Electrical connection male plug M12x1 (5-pin) / metal version customer Mechanical connection G1/2" DIN 3852 G1/2" EN 837 G1/4" DIN 3852 G1/4" EN 837 G1/2" DIN 3852 with flush sensor 1/2" NPT 1/4" NPT customer Seal FKM without (welded version) customer Special version standard customer absolute pressure...

Open the catalog to page 5