data sheet DPT 100
4Pages

{{requestButtons}}

Catalog excerpts

data sheet DPT 100 - 1

DPT 100 Differential Pressure Transmitter for Process Industry accuracy according to IEC 60770: 0.1 % FSO The differential pressure transmitter DPT 100 has been especially designed for fast test processes in leakage and flow measurement, where a fast response time and high sampling rate are necessary. from 10 mbar up to 20 bar Static pressure The compact design of the DPT 100 facilitates the usage in standardised applications. For instance, the installation in 19" racks. Output signal The DPT 100 with optionally RS485 interface uses the communication protocol Modbus RTU which has found the way in industrial communication as an open protocol. The Modbus protocol is based on a master Slave architecture with which up to 247 Slaves can be questioned by a master – the data will transfer in binary form. 2-wire: 4 ... 20 mA RS485 with Modbus RTU protocol Special characteristics ► compact design fast response time aluminium die cast case zero adjustment via button Preferred areas of use are Test engineering / leak testing Machine and plant engineering several process connections Environmental technology Energy production BD SENSORS GmbH BD-Sensors-Straße 1 D - 95199 Thierstein

Open the catalog to page 1
data sheet DPT 100 - 2

DPT 100 Differential Pressure Transmitter Differential pressure ranges Pressure range pN diff. Pressure range pN symmetric (diff.) Permissible static pressure Output signal / Supply Standard Option Performance Accuracy 1 Technical Data 4 ... 20 mA / VS = 12 ... 32 VDC RS 485 with Modbus RTU protocol / VS = 9 … 32 VDC (delay time: 500 msec) pN ≥ 60 mbar: ≤ ± 0.1 % FSO pN < 60 mbar: ≤ ± 0.2 % FSO Permissible load Rmax = [(VS – VS min) / 0.02 A] Ω Influence supply supply: 0.05 % FSO / 10 V load: 0.05 % FSO / kΩ Influence static pressure pN 10 mbar 60 mbar 400 mbar 2.5 bar [Pa/100 bar] 18 30 40...

Open the catalog to page 2
data sheet DPT 100 - 3

DPT 100 Miscellaneous Mounting bracket (optionally) Ingress protection Installation position Weight Current consumption Operational life CE-conformity Technical Data material C-steel or stainless steel 1.4401 (304) weight 0.45 kg (incl. bolts and nuts) IP 66 / IP 67 any 2 approx. 1800 g approx. 23 mA 100 million load cycles EMC Directive: 2014/30/EU Pressure Equipment Directive: 2014/68/EU (module A) 3 Pressure transmitters are calibrated in a vertical position with the pressure connection down. If this position is changed on installation there can be slight deviations in the zero point....

Open the catalog to page 3
data sheet DPT 100 - 4

Pressure differential pressure Accuracy pN ≥ 60 mbar: pN < 60 mbar: Housing aluminium customer Electrical connection terminals / cable gland M12x1.5 male plug M12x1 (4-pin) / metal customer Process connection 1/4" - 18 NPT F / fixing 7/16 UNF 1/4" - 18 NPT (F / vertical) / fixing 7/16 UNF 1/4" - 18 NPT F / fixing M10 1/4" - 18 NPT (F / vertical) / fixing M10 Valve without with vent with vent (top) with vent (bottom) Material pressure port, flange, valves, etc. stainless steel 1.4401 (316 SS) customer Diaphragm / filling fluid stainless steel 1.4435 (316L) / silicone oil customer Seal FKM...

Open the catalog to page 4

All BD|SENSORS GmbH catalogs and technical brochures

  1. DMK 351P

    5 Pages

  2. 18.601 G

    3 Pages

  3. 17.620 G

    3 Pages

  4. DCT 561

    4 Pages

  5. XMD

    5 Pages

  6. DPT 200

    5 Pages

  7. LMP 331I

    4 Pages

  8. EP 500

    4 Pages