data sheet DPS 200 - 1

DPS 200 Differential Pressure Transmitter for Gas and Compressed Air Applications: ► piezoresistive silicon sensor differential pressure range 6 ... 1000 mbar Technical Data Input pressure range Nominal pressure PN [mbar] (differential, gauge pressure) max. static pressure [mbar] Output signal / Supply Standard Option Performance Accuracy ≤ ± 1% FSO BFSL current 2-wire: Rmax = [(VS - VSmin) / 0,02 A] Ω current 3-wire: 330 Ω voltage 3-wire: 10 kΩ Influence effects supply: ≤ ± 0.1 % FSO/10V load: ≤ ± 0.1 % FSO/kΩ Response time (0 ... 100%) 2-wire: adjustable by potentiometer in the range of 500 msec up to 2.5 sec 3-wire: adjustable by potentiometer in the range of 50 msec up to 2.5 sec Long term stability ≤ ± 0.5 % FSO / year at reference conditions Measuring rate 2-wire: 8 Hz 3-wire: 1 kHz Thermal effects (offset and span) Thermal error ≤ ± 0.3 % FSO / 10 K (typ.) in compensated range 0 ... 50 °C Permissible temperatures Medium 0 … 50°C Electronics / environment 0 … 50°C Storage -10 … 70°C Electrical protection Short-circuit protection permanent Reverse polarity protection no damage, but also no function Electromagnetic protection emission and immunity according to EN 61326 Materials Pressure port brass nickel plated Housing ABS Sensor ceramic, silicon, epoxy, RTV Media wetted parts pressure port, PVC / silicone tube, sensor Permissible load BD SENSORS GmbH BD-Sensors-Straße 1 D - 95199 Thierstein

Open the catalog to page 1
data sheet DPS 200 - 2

DPS 200 Miscellaneous LC-Display (optional) Current consumption Units Ingress protection Weight Installation position Operational life 1 Technical Data visible range 32.5 x 22.5 mm; 5-digit 7-segment-main display, digit size 8 mm; 8-digit 14-segment-additional display, digit size 5 mm; 52-segment-bargraph 2-wire: signal output current: max. 22 mA 3-wire: signal output current: max. 30 mA signal output voltage: 7.5 mA (20 mA short circuit) display: + 1 mA following units can be set at factory: [bar], [mbar], [PSI], [Inch Hg], [cm Hg], [mm Hg], [hPa], [kPa], [MPa], [mH2O], [Pa], [mmH2O] IP 54...

Open the catalog to page 2
data sheet DPS 200 - 3

Display without display LC display customer Front foil BD SENSORS neutral customer Mechanical connection Ø6.6 x 11 (for flex. tubes Ø6) Ø4.4 x 10 (for flex. tubes Ø4) Pressure port brass nickel plated customer Special version standard customer © 2022 BD|SENSORS GmbH - The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials.

Open the catalog to page 3

All BD|SENSORS GmbH catalogs and technical brochures

  1. DMK 351P

    5 Pages

  2. 18.601 G

    3 Pages

  3. 17.620 G

    3 Pages

  4. DCT 561

    4 Pages

  5. XMD

    5 Pages

  6. DPT 200

    5 Pages

  7. LMP 331I

    4 Pages

  8. EP 500

    4 Pages