Catalog excerpts
DMP 457 Pressure Transmitter for Shipbuilding and Offshore Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO The pressure transmitter DMP 457 has been especially designed for rough conditions occurring especially in shipbuilding and offshore applications. All gaseous and liquid media, which are compatible with stainless steel 1.4404 (316L) respectively can be used. from 0 ... 100 mbar up to 0 ... 600 bar Output signals 2-wire: 4 ... 20 mA others on request Special characteristics ► LR-certificate (Lloyd´s Register) DNV-approval (Det Norske Veritas) ABS-certificate (American Bureau of Shipping) CCS-certificate (China Classification Society) flush pressure port G 1/2" from 100 mbar excellent thermal behaviour Preferred areas of use are Diesel engines, drives Compressors, pumps Boiler Hydraulic and pneumatic control systems IS-version Ex ia = intrinsically safe for gases and dusts Sensor element is a piezoresistive stainless steel sensor with high accuracy and excellent long-term stability. In order to meet the special requirements for shipbuilding and offshore applications extensive tests had to be passed to get the Lloyd´s Register (LR), Det Norske Veritas (DNV) and China Classification Society (CCS) approvals. welded pressure port BD SENSORS GmbH BD-Sensors-Straße 1 D - 95199 Thierstein
Open the catalog to page 1DMP 457 Pressure Transmitter for Shipbuilding and Offshore Input pressure range 1 Nominal pressure gauge [bar] Nominal pressure absolute [bar] Level gauge / abs. [mH2O] Overpressure [bar] Burst pressure ≥ [bar] Technical Data Nominal pressure gauge [bar] 10 16 25 40 Nominal pressure abs. [bar] 10 16 25 40 Level gauge / abs. [mH2O] 100 160 250 400 Overpressure [bar] 40 80 80 105 Burst pressure > [bar] 50 120 120 210 Vacuum resistance pN ≥ 1 bar: unlimited vacuum resistance 1 from 60 bar: measurement starts with ambient pressure Output signal / Supply Standard Option IS-version Performance...
Open the catalog to page 2DMP 457 Pressure Transmitter for Shipbuilding and Offshore Explosion protection Approvals DX19-DMP 457 Safety technical maximum values Permissible temperatures for environment Connecting cables (by factory) Miscellaneous Current consumption Weight Installation position Operational life CE-conformity IBExU 10 ATEX 1068 X / IECEx IBE 12.0027X zone 0: II 1G Ex ia IIB T4 Ga zone 20: II 1D Ex ia IIIC T135 °C Da Ui = 28 V, Ii = 93 mA, Pi = 660 mW, Li ≈ 0 µH with field housing: Ci = 105 nF with cable outlet: Ci = 84.7 nF with ISO 4400: Ci = 62.2 nF the supply connections have an inner capacity of...
Open the catalog to page 3DMP 457 Pressure Transmitter for Shipbuilding and Offshore Technical Data universal field housing (IP 67) Generally shielded cable has to be used! Cable versions are delivered with shielded cable. For ISO 4400 the use of shielded cable is compulsory. tested at 4 bar or 40 mH2O for 24 hours 8 shielded cable with integrated air tube for atmospheric reference (for nominal pressure ranges absolute, the air tube is closed); different lengths available * total lengths increase by 9 mm for pN ≥ 100 bar with the optional accuracy ≤ ± 0.25 % FSO 7 Mechanical connections (dimensions mm / in) * total...
Open the catalog to page 4Output 4 … 20 mA / 2-wire intrinsic safety 4 … 20 mA / 2-wire customer Accuracy standard for p N ≥ 0,4 bar: 0.35 % FSO standard for p N < 0,4 bar: 0.50 % FSO option for pN ≥ 0,4 bar: 0.25 % FSO customer Electrical connection male and female plug ISO 4400 (for cable Ø 4...6 mm) male and female plug ISO 4400 GL (for cable Ø 10...14 mm) male and female plug ISO 4400 GL (for cable Ø 4,5...11 mm) cable outlet (TPE-U-cable) field housing stainless steel (316L) submersible version (1.4404 / 316L) with TPE-U-cable customer Mechanical connection G1/2" DIN 3852 G1/2" EN 837 G1/4" DIN 3852 G1/4" EN...
Open the catalog to page 5All BD|SENSORS GmbH catalogs and technical brochures
-
data sheet LMK 307 T
5 Pages
-
data sheet DMP 334i
5 Pages
-
data sheet DS 4
4 Pages
-
data sheet DS 202
5 Pages
-
data sheet DMP 335
5 Pages
-
BD|SENSORS at a glance
5 Pages
-
data sheet LMK 806
4 Pages
-
data sheet DL 01
6 Pages
-
data sheet DM 01
6 Pages
-
data sheet LMK 807
4 Pages
-
data sheet LMP 308 i
5 Pages
-
data sheet LMP 305
5 Pages
-
data sheet LMP 808
4 Pages
-
data sheet LMP 307
5 Pages
-
data sheet LMP 308
5 Pages
-
data sheet LMP 331i
5 Pages
-
date sheet LMP 307i
5 Pages
-
data sheet LMK 808
4 Pages
-
data sheet LMP 331
4 Pages
-
data sheet LMK 858
4 Pages
-
data sheet LMK 809
4 Pages
-
data sheet LMK 458
5 Pages
-
data sheet LMP 307 T
5 Pages
-
data sheet LMK 307
4 Pages
-
data sheet LMK 382
6 Pages
-
data sheet LMK 306
4 Pages
-
data sheet LMK 387
6 Pages
-
data sheet LMK 358 H
5 Pages
-
data sheet LMK 487
5 Pages
-
data sheet LMK 458 H
5 Pages
-
data sheet LMK 358
5 Pages
-
data sheet LMK 382 H
5 Pages
-
datasheet DCT 531i
5 Pages
-
data sheet DS 6
3 Pages
-
data sheet DS 200P
6 Pages
-
data sheet DCL 571
6 Pages
-
data sheet DS 350
5 Pages
-
data sheet BAROLI 02
3 Pages
-
datasheet DMP 336
4 Pages
-
data sheet DS 400
5 Pages
-
data sheet DS 201P
6 Pages
-
data sheet DS 401
5 Pages
-
data sheet DMP 331 Pi
6 Pages
-
data sheet DS 201
6 Pages
-
data sheet BAROLI 05
3 Pages
-
data sheet DS217
3 Pages
-
data sheet DS 200
6 Pages
-
data sheet DS210
5 Pages
-
data sheet DS 230
3 Pages
-
data sheet DMK 331
5 Pages
-
data sheet x|act i
5 Pages
-
data sheet x|act ci
5 Pages
-
data sheet DCT 531
4 Pages
-
data sheet DMP 331
6 Pages
-
data sheet XMP ci
5 Pages
-
data sheet XMP i
6 Pages
-
data sheet DMP 321
6 Pages
-
data sheet DCT 532
5 Pages
-
data sheet DCT 533
4 Pages
-
data sheet DMP i
6 Pages
-
data sheet BAROLI 02P
4 Pages
-
data sheet DS 350P
5 Pages
-
data sheet DS 5
3 Pages
-
data sheet DS 233
5 Pages
-
data sheet LMK 351
4 Pages
-
data sheet DPT 200
10 Pages
-
data sheet DMK 387
5 Pages
-
data sheet DMP 334
4 Pages
-
data sheet DMP 343
5 Pages
-
data sheet DMP 333
6 Pages
-
data sheet 351
5 Pages
-
data sheet DMK 331 P
5 Pages
-
data sheet DMP 339P
4 Pages
-
data sheet DMK 458
5 Pages
-
data sheet DMK 351 P
5 Pages
-
data sheet DMP 331 P
6 Pages
-
data sheet 26.600 G
3 Pages
-
data sheet 17.620 G
3 Pages
-
data sheet iS4
4 Pages
-
data sheet 18.605 G
3 Pages
-
data sheet 30.600 G
3 Pages
-
data sheet 18.601 G
3 Pages
-
data sheet 18.600 G
3 Pages
-
data sheet 17.609 G
3 Pages
-
data sheet 17.600G
3 Pages
-
data sheet DPT 100
4 Pages
-
data sheet DMP 339
5 Pages
-
data sheet DPS 300
5 Pages
-
data sheet DM 10
3 Pages
-
data sheet DMK 457
5 Pages
-
data sheet DMP 320
5 Pages
-
data sheet DPS 200
3 Pages
-
data sheet PA 440
3 Pages
-
data sheet DMD 331
4 Pages
-
datasheet DCT 553P
4 Pages
-
data sheet DMK456
4 Pages
-
datasheet DCT 531P
5 Pages
-
data sheet DCT 562
5 Pages
-
data sheet DCT 563
4 Pages
-
datasheet DCT 533P
4 Pages
-
data sheet DCT 561
4 Pages
-
data sheet DCT 571
5 Pages
-
data sheet LMK 387H
5 Pages
-
Data sheet DMD 831
3 Pages
-
data sheet DS 351
5 Pages
-
data sheet HU 300
5 Pages
-
DMK 351P
5 Pages
-
18.601 G
3 Pages
-
17.620 G
3 Pages
-
DCT 561
4 Pages
-
displays and evaluation devices
44 Pages
-
XMD
5 Pages
-
DPT 200
5 Pages
-
LMP 331I
4 Pages
-
KL 2terminal box plastics
3 Pages
-
KL 1terminal box aluminium
3 Pages
-
EP 500
4 Pages
-
product catalogue overall
48 Pages
-
Piezoelektrische Druckmessung
56 Pages
-
BD|SENSORS at a glance
5 Pages