Catalog excerpts

DMP 331P Industrial Pressure Transmitter Process Connections with Flush Welded Stainless Steel Diaphragm accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO Nominal pressure The pressure transmitter DMP 331P was designed for use in the food / beverage and pharmaceutical industry. The compact design with hygienic versions makes it possible to achieve an outstanding performance in terms of accuracy, temperature behaviour and long term stability. from 0 ... 100 mbar up to 0 ... 40 bar Output signals 2-wire: 4 ... 20 mA / 3-wire: 0 ... 10 V others on request The modular construction concept allows a combination of various process connections with different filling fluids and a cooling element. Several electrical connections complete the profile of DMP 331P. hygienic version diaphragm with low surface roughness CIP / SIP cleaning up to 150 °C vacuum resistant Preferred areas of use are Optional versions Food and beverage ► IS-version Ex ia = intrinsically safe for gases and dust Pharmaceutical industry diaphragm in Hastelloy® or Tantalum cooling element for media temperatures up to 300 °C BD SENSORS GmbH BD-Sensors-Straße 1 D - 95199 Thierstein Material and test certificates Inspection certificate 3.1 according to EN 10204 Test report 2.2 according to EN 10204
Open the catalog to page 1
DMP 331P Industrial Pressure Transmitter Input pressure range 1 Nominal pressure gauge Nominal pressure absolute Overpressure Burst pressure ≥ Nominal pressure gauge / absolute Overpressure Burst pressure ≥ Vacuum resistance 1 Technical Data 10 20 40 15 25 50 pN > 1 bar: unlimited vacuum resistance pN ≤ 1 bar: on request standard: option: nominal pressure < 0.4 bar: nominal pressure ≥ 0.4 bar: nominal pressure ≥ 0.4 bar: Rmax = [(VS – VS min) / 0.02 A] Ω Rmax = 500 Ω Rmin = 10 kΩ current 2-wire: current 3-wire: voltage 3-wire: Influence effects Long term stability ≤ ± 0.1 % FSO / year at...
Open the catalog to page 2
DMP 331P Industrial Pressure Transmitter Technical Data Materials Pressure port Housing Option compact field housing stainless steel 1.4435 (316 L) stainless steel 1.4404 (316 L) stainless steel 1.4301 (304); cable gland M12x1.5, brass, nickel plated (clamping range 2 … 8 mm) standard: FKM (recommended for medium temperatures ≤ 200 °C) Seals option: FFKM (recommended for medium temperatures < 260 °C) Clamp, dairy pipe, Varivent®: without Diaphragm standard: stainless steel 1.4435 (316 L) option: Hastelloy® C-276 (2.4819) Media wetted parts pressure port, seal, diaphragm Explosion protection...
Open the catalog to page 3
DMP 331P Industrial Pressure Transmitter Technical Data Electrical connections (dimensions mm / in) compact field housing (IP 67) cable outlet with PVC cable (IP 67) 8 cable outlet, cable with ventilation tube (IP 68) 9 universal field housing stainless steel 1.4404 (316 L) with cable gland M20x1.5 (ordering code 880) and other versions on request standard: 2 m PVC cable without ventilation tube (permissible temperature: -5 … 70°C) different cable types and lengths available, permissible temperature depends on kind of cable
Open the catalog to page 4
DMP 331P Industrial Pressure Transmitter Technical Data G1" flush with radial o-ring G1/2" flush with radial o-ring pN ≥ 1 bar dairy pipe (DIN 11851) Clamp 3/4″ (DIN 32676) 4 bar ≤ pN ≤ 8 bar cooling element up to 300 °C 10 (optionally) SIL- and SIL-Ex version: total length increases by 26.5 mm! metric threads and other versions on request max. temperature depends on the used sealing material, type of seal and installation www.bdsensors.de info@bdsensors.de © 2024 BD|SENSORS GmbH – The specifications given in this document represent the state of engineeringat the time of publishing. We...
Open the catalog to page 5
Pressure Input 4 … 20 mA / 2-wire 0 … 20 mA / 3-wire 0 … 10 V / 3-wire intrinsic safety 4 … 20 mA / 2-wire SIL2 4 … 20 mA / 2-wire SIL2 with intrinsic safety 4 … 20 mA / 2-wire customer Accuracy standard for pN ≥ 0.4 bar: 0.35 % FSO standard for pN < 0.4 bar: 0.50 % FSO option for pN ≥ 0.4 bar: 0.25 % FSO customer Electrical connection male and female plug ISO 4400 male plug Binder series 723 (5-pin) cable outlet with PVC cable (IP67) 2 cable outlet, cable with ventilation tube (IP68) 3 male plug M12x1 (4-pin) / metal compact field housing stainless steel 1.4301 (304) 4 customer Mechanical...
Open the catalog to page 6All BD|SENSORS GmbH catalogs and technical brochures
-
data sheet DCT 541
4 Pages
-
data sheet HU 300
5 Pages
-
data sheet DMP 333P
5 Pages
-
data sheet DPT 200
10 Pages
-
data sheet LMK 809
4 Pages
-
data sheet DMP 334i
5 Pages
-
data sheet DS 202
5 Pages
-
data sheet LMK 351
4 Pages
-
data sheet DS 214
5 Pages
-
data sheet DS 233
5 Pages
-
data sheet DS 201
6 Pages
-
data sheet DS 200
6 Pages
-
data sheet LMP 331i
5 Pages
-
data sheet DMP i
6 Pages
-
data sheet DMP 331 Pi
6 Pages
-
data sheet DS 201P
6 Pages
-
data sheet LMK 806
4 Pages
-
data sheet DS 200P
6 Pages
-
data sheet DS210
5 Pages
-
data sheet DMP 335
5 Pages
-
data sheet LMK 307 T
5 Pages
-
data sheet DS 4
4 Pages
-
data sheet DL 01
6 Pages
-
data sheet DM 01
6 Pages
-
data sheet LMK 807
4 Pages
-
data sheet LMP 308 i
5 Pages
-
data sheet LMP 305
5 Pages
-
data sheet LMP 808
4 Pages
-
data sheet LMP 307
5 Pages
-
data sheet LMP 308
5 Pages
-
date sheet LMP 307i
5 Pages
-
data sheet LMK 808
4 Pages
-
data sheet LMP 331
4 Pages
-
data sheet LMK 858
4 Pages
-
data sheet LMK 458
5 Pages
-
data sheet LMP 307 T
5 Pages
-
data sheet LMK 307
4 Pages
-
data sheet LMK 382
6 Pages
-
data sheet LMK 306
4 Pages
-
data sheet LMK 387
6 Pages
-
data sheet LMK 358 H
5 Pages
-
data sheet LMK 487
5 Pages
-
data sheet LMK 458 H
5 Pages
-
data sheet LMK 358
5 Pages
-
data sheet LMK 382 H
5 Pages
-
datasheet DCT 531i
5 Pages
-
data sheet DS 6
3 Pages
-
data sheet DCL 571
6 Pages
-
data sheet DS 350
5 Pages
-
data sheet BAROLI 02
3 Pages
-
datasheet DMP 336
4 Pages
-
data sheet DS 400
5 Pages
-
data sheet DS 401
5 Pages
-
data sheet BAROLI 05
3 Pages
-
data sheet DS217
3 Pages
-
data sheet DMP 457
5 Pages
-
data sheet DS 230
3 Pages
-
data sheet DMK 331
5 Pages
-
data sheet x|act i
5 Pages
-
data sheet x|act ci
5 Pages
-
data sheet DCT 531
4 Pages
-
data sheet DMP 331
6 Pages
-
data sheet XMP ci
5 Pages
-
data sheet XMP i
6 Pages
-
data sheet DMP 321
6 Pages
-
data sheet DCT 532
5 Pages
-
data sheet DCT 533
4 Pages
-
data sheet BAROLI 02P
4 Pages
-
data sheet DS 350P
5 Pages
-
data sheet DS 5
3 Pages
-
data sheet DMK 387
5 Pages
-
data sheet DMP 334
4 Pages
-
data sheet DMP 343
5 Pages
-
data sheet DMP 333
6 Pages
-
data sheet 351
5 Pages
-
data sheet DMK 331 P
5 Pages
-
data sheet DMP 339P
4 Pages
-
data sheet DMK 458
5 Pages
-
data sheet DMK 351 P
5 Pages
-
data sheet 26.600 G
3 Pages
-
data sheet 17.620 G
3 Pages
-
data sheet iS4
4 Pages
-
data sheet 18.605 G
3 Pages
-
data sheet 30.600 G
3 Pages
-
data sheet 18.601 G
3 Pages
-
data sheet 18.600 G
3 Pages
-
data sheet 17.609 G
3 Pages
-
data sheet 17.600G
3 Pages
-
data sheet DPT 100
4 Pages
-
data sheet DMP 339
5 Pages
-
data sheet DPS 300
5 Pages
-
data sheet DM 10
3 Pages
-
data sheet DMK 457
5 Pages
-
data sheet DMP 320
5 Pages
-
data sheet DPS 200
3 Pages
-
data sheet PA 440
3 Pages
-
data sheet DMD 331
4 Pages
-
datasheet DCT 553P
4 Pages
-
data sheet DMK456
4 Pages
-
datasheet DCT 531P
5 Pages
-
data sheet DCT 562
5 Pages
-
data sheet DCT 563
4 Pages
-
datasheet DCT 533P
4 Pages
-
data sheet DCT 561
4 Pages
-
data sheet DCT 571
5 Pages
-
data sheet LMK 387H
5 Pages
-
Data sheet DMD 831
3 Pages
-
data sheet DS 351
5 Pages
-
DMK 351P
5 Pages
-
18.601 G
3 Pages
-
17.620 G
3 Pages
-
DCT 561
4 Pages
-
displays and evaluation devices
44 Pages
-
XMD
5 Pages
-
DPT 200
5 Pages
-
LMP 331I
4 Pages
-
KL 2terminal box plastics
3 Pages
-
KL 1terminal box aluminium
3 Pages
-
EP 500
4 Pages
-
product catalogue overall
48 Pages
-
Piezoelektrische Druckmessung
56 Pages
Archived catalogs
-
BD|SENSORS at a glance
5 Pages