DMK 457 Pressure Transmitter for Shipbuilding and Offshore Ceramic Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure The pressure transmitter DMK 457 with ceramic sensor has been designed for typical applications in shipbuilding and offshore constructions as alternative to our pressure transmitter DMP 457 with piezoresistive stainless steel sensor. from 0 ... 400 mbar up to 0 ... 600 bar Output signals 2-wire: 4 ... 20 mA others on request In combination with the copper-nickel-alloy the DMK 457 is suitable for seawater, e.g. level measurement in ballast tanks, etc. LR-certificate (Lloyd´s Register) DNV-approval (Det Norske Veritas) ABS-certificate (American Bureau of Shipping) CCS-certificate (China Classification Society) pressure port in CuNiFe (sea water resistant) oxygen application Preferred areas of use are Drives Compressors Boiler Pneumatic control systems Oxygen applications IS-version Ex ia = intrinsically safe for gases and dusts BD SENSORS GmbH BD-Sensors-Straße 1 D - 95199 Thierstein
Open the catalog to page 1
DMK 457 Pressure Transmitter for Shipbuilding and Offshore Input pressure range Nominal pressure gauge [bar] -1 … 0 0.4 0.6 1 1.6 2.5 4 6 Nominal pressure abs. [bar] - 0.6 1 1.6 2.5 4 6 Level gauge / abs. [mH2O] 6 10 16 25 40 60 Overpressure [bar] 4 1 2 2 4 4 10 10 Burst pressure ≥ [bar] 7 2 4 4 5 5 12 12 Vacuum resistance pN ≥ 1 bar: unlimited vacuum resistance pN < 1 bar: on request Output signal / Supply Standard Option IS-version Performance Accuracy 1 Permissible load Influence effects Long term stability Response time 1 Mechanical stability Vibration Materials Pressure port Cable...
Open the catalog to page 2
DMK 457 Pressure Transmitter for Shipbuilding and Offshore Explosion protection Approvals DX19-DMK 457 Safety technical maximum values Permissible temperatures for environment Connecting cables (by factory) Miscellaneous Option oxygen application IBExU 10 ATEX 1068 X / IECEx IBE 12.0027X zone 0: II 1G Ex ia IIB T4 Ga zone 20: II 1D Ex ia IIIC T135 °C Da Ui = 28 V, Ii = 93 mA, Pi = 660 mW, Li ≈ 0 µH with field housing: Ci = 105 nF with cable outlet: Ci = 84.7 nF with ISO 4400: Ci = 62.2 nF the supply connections have an inner capacity of max. 90 nF (140 nF with field housing) to the housing...
Open the catalog to page 3
DMK 457 Pressure Transmitter for Shipbuilding and Offshore Technical Data Electrical connections 5 (dimensions mm / in) universal field housing (IP 67) Generally shielded cable has to be used! Cable versions are delivered with shielded cable. For ISO 4400 the use of shielded cable is compulsory. tested at 4 bar or 40 mH2O for 24 hours 7 shielded cable with integrated air tube for atmospheric reference (for nominal pressure ranges absolute, the air tube is closed); different lengths available 6 Mechanical connection (dimensions mm / in) www.bdsensors.de info@bdsensors.de © 2022 BD|SENSORS...
Open the catalog to page 4
Output 4 … 20 mA / 2-wire intrinsic safety 4 … 20 mA / 2-wire customer Accuracy 0.5 % FSO customer Electrical connection male and female plug ISO 4400 (for cable Ø 4...6 mm) male and female plug ISO 4400 GL (for cable Ø 10...14 mm) male and female plug ISO 4400 GL (for cable Ø 4.5...11 mm) cable outlet with TPE-U-cable field housing stainless steel 1.4404 (316L) submersible version in 1.4404 (316L) with TPE-U-cable submersible version in CuNiFe with TPE-U-cable customer Mechanical connection G1/2" DIN 3852 G1/2" EN 837 G1/4" DIN 3852 G1/4" EN 837 G1/2" DIN 3852 open pressure port 1/2" NPT...
Open the catalog to page 5All BD|SENSORS GmbH catalogs and technical brochures
-
data sheet DCT 541
4 Pages
-
data sheet HU 300
5 Pages
-
data sheet DMP 333P
5 Pages
-
data sheet DPT 200
10 Pages
-
data sheet LMK 809
4 Pages
-
data sheet DMP 334i
5 Pages
-
data sheet DS 202
5 Pages
-
data sheet LMK 351
4 Pages
-
data sheet DS 214
5 Pages
-
data sheet DS 233
5 Pages
-
data sheet DS 201
6 Pages
-
data sheet DS 200
6 Pages
-
data sheet LMP 331i
5 Pages
-
data sheet DMP i
6 Pages
-
data sheet DMP 331 Pi
6 Pages
-
data sheet DMP 331 P
6 Pages
-
data sheet DS 201P
6 Pages
-
data sheet LMK 806
4 Pages
-
data sheet DS 200P
6 Pages
-
data sheet DS210
5 Pages
-
data sheet DMP 335
5 Pages
-
data sheet LMK 307 T
5 Pages
-
data sheet DS 4
4 Pages
-
data sheet DL 01
6 Pages
-
data sheet DM 01
6 Pages
-
data sheet LMK 807
4 Pages
-
data sheet LMP 308 i
5 Pages
-
data sheet LMP 305
5 Pages
-
data sheet LMP 808
4 Pages
-
data sheet LMP 307
5 Pages
-
data sheet LMP 308
5 Pages
-
date sheet LMP 307i
5 Pages
-
data sheet LMK 808
4 Pages
-
data sheet LMP 331
4 Pages
-
data sheet LMK 858
4 Pages
-
data sheet LMK 458
5 Pages
-
data sheet LMP 307 T
5 Pages
-
data sheet LMK 307
4 Pages
-
data sheet LMK 382
6 Pages
-
data sheet LMK 306
4 Pages
-
data sheet LMK 387
6 Pages
-
data sheet LMK 358 H
5 Pages
-
data sheet LMK 487
5 Pages
-
data sheet LMK 458 H
5 Pages
-
data sheet LMK 358
5 Pages
-
data sheet LMK 382 H
5 Pages
-
datasheet DCT 531i
5 Pages
-
data sheet DS 6
3 Pages
-
data sheet DCL 571
6 Pages
-
data sheet DS 350
5 Pages
-
data sheet BAROLI 02
3 Pages
-
datasheet DMP 336
4 Pages
-
data sheet DS 400
5 Pages
-
data sheet DS 401
5 Pages
-
data sheet BAROLI 05
3 Pages
-
data sheet DS217
3 Pages
-
data sheet DMP 457
5 Pages
-
data sheet DS 230
3 Pages
-
data sheet DMK 331
5 Pages
-
data sheet x|act i
5 Pages
-
data sheet x|act ci
5 Pages
-
data sheet DCT 531
4 Pages
-
data sheet DMP 331
6 Pages
-
data sheet XMP ci
5 Pages
-
data sheet XMP i
6 Pages
-
data sheet DMP 321
6 Pages
-
data sheet DCT 532
5 Pages
-
data sheet DCT 533
4 Pages
-
data sheet BAROLI 02P
4 Pages
-
data sheet DS 350P
5 Pages
-
data sheet DS 5
3 Pages
-
data sheet DMK 387
5 Pages
-
data sheet DMP 334
4 Pages
-
data sheet DMP 343
5 Pages
-
data sheet DMP 333
6 Pages
-
data sheet 351
5 Pages
-
data sheet DMK 331 P
5 Pages
-
data sheet DMP 339P
4 Pages
-
data sheet DMK 458
5 Pages
-
data sheet DMK 351 P
5 Pages
-
data sheet 26.600 G
3 Pages
-
data sheet 17.620 G
3 Pages
-
data sheet iS4
4 Pages
-
data sheet 18.605 G
3 Pages
-
data sheet 30.600 G
3 Pages
-
data sheet 18.601 G
3 Pages
-
data sheet 18.600 G
3 Pages
-
data sheet 17.609 G
3 Pages
-
data sheet 17.600G
3 Pages
-
data sheet DPT 100
4 Pages
-
data sheet DMP 339
5 Pages
-
data sheet DPS 300
5 Pages
-
data sheet DM 10
3 Pages
-
data sheet DMP 320
5 Pages
-
data sheet DPS 200
3 Pages
-
data sheet PA 440
3 Pages
-
data sheet DMD 331
4 Pages
-
datasheet DCT 553P
4 Pages
-
data sheet DMK456
4 Pages
-
datasheet DCT 531P
5 Pages
-
data sheet DCT 562
5 Pages
-
data sheet DCT 563
4 Pages
-
datasheet DCT 533P
4 Pages
-
data sheet DCT 561
4 Pages
-
data sheet DCT 571
5 Pages
-
data sheet LMK 387H
5 Pages
-
Data sheet DMD 831
3 Pages
-
data sheet DS 351
5 Pages
-
DMK 351P
5 Pages
-
18.601 G
3 Pages
-
17.620 G
3 Pages
-
DCT 561
4 Pages
-
displays and evaluation devices
44 Pages
-
XMD
5 Pages
-
DPT 200
5 Pages
-
LMP 331I
4 Pages
-
KL 2terminal box plastics
3 Pages
-
KL 1terminal box aluminium
3 Pages
-
EP 500
4 Pages
-
product catalogue overall
48 Pages
-
Piezoelektrische Druckmessung
56 Pages
Archived catalogs
-
BD|SENSORS at a glance
5 Pages