Catalog excerpts
DMK 387 Pressure Transmitter Ceramic sensor accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO Nominal pressure The pressure transmitter DMK 387 has been specially designed for applications in plant and machine engineering as well as laboratory techniques and is suitable for measuring small system pressure and filling heights. from 0 ... 100 mbar up to 0 ... 60 bar Output signal 2-wire: 4 ... 20 mA 3-wire and others on request By using our own-developed capacitive sensor, available in AI2O3 99.9%, the DMK 387 offers a high overpressure resistance and a high temperature and media resistance. The pressure transmitter is available in an intrinsically safe version for usage in explosive environments. high long-term stability Plant and machine engineering IS-version Ex ia = intrinsically safe for gases and dust Laboratory techniques different kinds of inch threads pressure port in PVDF or PP-HT for aggressive media Aggressive media BD SENSORS GmbH BD-Sensors-Straße 1 D - 95199 Thierstein www.bdsensors.de info@bdse
Open the catalog to page 1DMK 387 Pressure Transmitter Input pressure range Nominal pressure gauge [bar] Level [mH2O] Overpressure [bar] Burst pressure ≥ [bar] Permissible vacuum [bar] Output signal / Supply Standard Option IS-version On request Performance Accuracy 1 Permissible load Influence effects Long term stability Turn-on time Mean response time Measuring rate 1 standard: ≤ ± 0.35 % FSO option: ≤ ± 0.25 % FSO current 2-wire: Rmax = [(VS – VS min) / 0.02 A] Ω voltage 3-wire: Rmin = 10 kΩ supply: 0.05 % FSO / 10 V load: 0.05 % FSO / kΩ ≤ ± 0.1 % FSO / year 450 msec ≤ 70 msec 80 Hz accuracy according to IEC...
Open the catalog to page 2Technical Data Miscellaneous Current consumption Weight Operational life CE-conformity ATEX Directive Wiring diagrams max. 22 mA approx. 180 g 100 million load cycles EMC Directive: 2014/30/EU 2014/34/EU Pin configuration Electrical connection compact field housing cable colours (IEC 60757) VS+ VS- S+ GND supply + supply – signal + (only 3-wire) Shield WH (white) BN (brown) GN (green) GNYE (green-yellow) Electrical connections (dimensions mm / in) compact field housing (IP 67) cable outlet with PVC-cable (IP 67) 3 cable outlet, cable with ventilation tube (IP 68) 4 universal field housing...
Open the catalog to page 3Technical Data not in combination with field housing www.bdsensors.de info@bdsensors.de © 2021 BD|SENSORS GmbH – The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials.
Open the catalog to page 4Output 4 … 20 mA / 2-wire 0 … 10 V / 3-wire intrinsic safety 4 … 20 mA / 2-wire customer Accuracy standard 0.35 % FSO 0.25 % FSO option customer Electrical connection male and female plug ISO 4400 male plug Binder series 723 (5-pin) cable outlet with PVC cable (IP67) cable outlet, cable with ventilation tube (IP68) male plug M12x1 (4-pin) / metal compact field housing stainless steel 1.4301 (304) customer Mechanical connection G1/2" DIN 3852 G1/2" EN 837 G1/4" DIN 3852 G1/4" EN 837 G3/4" with flush sensor customer Seal FKM EPDM FFKM customer Pressure port stainless steel 1.4404 (316L) PVDF...
Open the catalog to page 5All BD|SENSORS GmbH catalogs and technical brochures
-
data sheet DCT 541
4 Pages
-
data sheet DMP 333P
5 Pages
-
data sheet DPT 200
10 Pages
-
data sheet LMK 809
4 Pages
-
data sheet DMP 334i
5 Pages
-
data sheet DS 202
5 Pages
-
data sheet LMK 351
4 Pages
-
data sheet DS 214
5 Pages
-
data sheet DS 233
5 Pages
-
data sheet DS 201
6 Pages
-
data sheet DS 200
6 Pages
-
data sheet LMP 331i
5 Pages
-
data sheet DMP i
6 Pages
-
data sheet DMP 331 Pi
6 Pages
-
data sheet DMP 331 P
6 Pages
-
data sheet DS 201P
6 Pages
-
data sheet LMK 806
4 Pages
-
data sheet DS 200P
6 Pages
-
data sheet DS210
5 Pages
-
data sheet DMP 335
5 Pages
-
data sheet LMK 307 T
5 Pages
-
data sheet DS 4
4 Pages
-
BD|SENSORS at a glance
5 Pages
-
data sheet DL 01
6 Pages
-
data sheet DM 01
6 Pages
-
data sheet LMK 807
4 Pages
-
data sheet LMP 308 i
5 Pages
-
data sheet LMP 305
5 Pages
-
data sheet LMP 808
4 Pages
-
data sheet LMP 307
5 Pages
-
data sheet LMP 308
5 Pages
-
date sheet LMP 307i
5 Pages
-
data sheet LMK 808
4 Pages
-
data sheet LMP 331
4 Pages
-
data sheet LMK 858
4 Pages
-
data sheet LMK 458
5 Pages
-
data sheet LMP 307 T
5 Pages
-
data sheet LMK 307
4 Pages
-
data sheet LMK 382
6 Pages
-
data sheet LMK 306
4 Pages
-
data sheet LMK 387
6 Pages
-
data sheet LMK 358 H
5 Pages
-
data sheet LMK 487
5 Pages
-
data sheet LMK 458 H
5 Pages
-
data sheet LMK 358
5 Pages
-
data sheet LMK 382 H
5 Pages
-
datasheet DCT 531i
5 Pages
-
data sheet DS 6
3 Pages
-
data sheet DCL 571
6 Pages
-
data sheet DS 350
5 Pages
-
data sheet BAROLI 02
3 Pages
-
datasheet DMP 336
4 Pages
-
data sheet DS 400
5 Pages
-
data sheet DS 401
5 Pages
-
data sheet BAROLI 05
3 Pages
-
data sheet DS217
3 Pages
-
data sheet DMP 457
5 Pages
-
data sheet DS 230
3 Pages
-
data sheet DMK 331
5 Pages
-
data sheet x|act i
5 Pages
-
data sheet x|act ci
5 Pages
-
data sheet DCT 531
4 Pages
-
data sheet DMP 331
6 Pages
-
data sheet XMP ci
5 Pages
-
data sheet XMP i
6 Pages
-
data sheet DMP 321
6 Pages
-
data sheet DCT 532
5 Pages
-
data sheet DCT 533
4 Pages
-
data sheet BAROLI 02P
4 Pages
-
data sheet DS 350P
5 Pages
-
data sheet DS 5
3 Pages
-
data sheet DMP 334
4 Pages
-
data sheet DMP 343
5 Pages
-
data sheet DMP 333
6 Pages
-
data sheet 351
5 Pages
-
data sheet DMK 331 P
5 Pages
-
data sheet DMP 339P
4 Pages
-
data sheet DMK 458
5 Pages
-
data sheet DMK 351 P
5 Pages
-
data sheet 26.600 G
3 Pages
-
data sheet 17.620 G
3 Pages
-
data sheet iS4
4 Pages
-
data sheet 18.605 G
3 Pages
-
data sheet 30.600 G
3 Pages
-
data sheet 18.601 G
3 Pages
-
data sheet 18.600 G
3 Pages
-
data sheet 17.609 G
3 Pages
-
data sheet 17.600G
3 Pages
-
data sheet DPT 100
4 Pages
-
data sheet DMP 339
5 Pages
-
data sheet DPS 300
5 Pages
-
data sheet DM 10
3 Pages
-
data sheet DMK 457
5 Pages
-
data sheet DMP 320
5 Pages
-
data sheet DPS 200
3 Pages
-
data sheet PA 440
3 Pages
-
data sheet DMD 331
4 Pages
-
datasheet DCT 553P
4 Pages
-
data sheet DMK456
4 Pages
-
datasheet DCT 531P
5 Pages
-
data sheet DCT 562
5 Pages
-
data sheet DCT 563
4 Pages
-
datasheet DCT 533P
4 Pages
-
data sheet DCT 561
4 Pages
-
data sheet DCT 571
5 Pages
-
data sheet LMK 387H
5 Pages
-
Data sheet DMD 831
3 Pages
-
data sheet DS 351
5 Pages
-
data sheet HU 300
5 Pages
-
DMK 351P
5 Pages
-
18.601 G
3 Pages
-
17.620 G
3 Pages
-
DCT 561
4 Pages
-
displays and evaluation devices
44 Pages
-
XMD
5 Pages
-
DPT 200
5 Pages
-
LMP 331I
4 Pages
-
KL 2terminal box plastics
3 Pages
-
KL 1terminal box aluminium
3 Pages
-
EP 500
4 Pages
-
product catalogue overall
48 Pages
-
Piezoelektrische Druckmessung
56 Pages
-
BD|SENSORS at a glance
5 Pages