data sheet DMK 351 P
1 / 5Pages

Catalog excerpts

data sheet DMK 351 P - 1

DMK 351P Pressure Transmitter for the Process Industry Ceramic Sensor accuracy according to IEC 60770: Standard: 0.35 % FSO Option: 0.25 % FSO The pressure transmitter DMK 351P has been designed for measuring small system pressure in the food industry and chemical industry. from 0 … 40 mbar up to 0 … 20 bar Output signal The DMK 351P is based on an own-developed capacitive ceramic sensor element. It features high overpressure resistance and high resistance against most of aggressive media. A variety of different process and electrical connections and an intrinsically safe version complete the range of possibilities. 2-wire: 4 ... 20 mA 3-wire: 0 ... 10 V others on request Special characteristics ► hygienic version different process connections (G1 1/2", diary pipe, Clamp, etc.) high overpressure capability Preferred areas of use are Food industry Chemical and petrochemical industry IS-version Ex ia = intrinsically safe for gases and dusts Preferred used for Paint and varnish customer specific versions e.g. special pressure ranges BD SENSORS GmbH BD-Sensors-Straße 1 D - 95199 Thierstein Viscous and pasty media

Open the catalog to page 1
data sheet DMK 351 P - 2

DMK 351P Process Pressure Transmitter Pressure ranges Nominal pressure gauge Nominal pressure absolute Overpressure Permissible vacuum Output signal / Supply Standard Option IS-protection Option 3-wire Performance Accuracy 1 Long term stability Influence effects Permissible load Turn-on time Mean measuring rate Response time 1 Technical Data standard:   0.35 % FSO option for pN ≥ 0.6 bar:   0.25 % FSO ≤ ± 0.1 % FSO / year at reference conditions supply: 0.05 % FSO / 10 V load: 0.05 % FSO / kΩ current 2-wire: Rmax = [(VS – VS min) / 0.02 A] Ω voltage 3-wire: Rmin = 10 kΩ 700 msec 5 / sec...

Open the catalog to page 2
data sheet DMK 351 P - 3

DMK 351P Process Pressure Transmitter Technical Data Wiring diagram 2-wire-system (current) Pin configuration Electrical connection Supply + Supply – Signal + (only 3-wire) Shield compact field housing IN + IN – OUT + cable colours (IEC 60757) WH (white) BN (brown) GN (green) GNYE (green-yellow) Electrical connections (dimensions in mm) standard compact field housing (IP 67) cable outlet with PVC-cable (IP 67) 2 cable outlet, cable with ventilation tube (IP 68) 3 universal stainless steel field housing 1.4404 with cable gland M20x1.5 (ordering code 880) and other versions on request...

Open the catalog to page 3
data sheet DMK 351 P - 4

DMK 351P Process Pressure Transmitter Technical Data Mechanical connections (dimensions in mm) dairy pipe (DIN 11851) dimensions in mm size DN 40 DN 50 A 56 68.5 mounting flange is included in the delivery (already pre-assembled) www.bdsensors.de info@bdsensors.de © 2022 BD|SENSORS GmbH – The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials

Open the catalog to page 4
data sheet DMK 351 P - 5

Output 4 … 20 mA / 2-wire 0 … 10 V / 3-wire intrinsic safety 4 … 20 mA / 2-wire customer Accuracy standard: 0.35 % FSO option for pN ≥ 0.6 bar: 0.25 % FSO customer Electrical connection male and female plug ISO 4400 male plug Binder series 723 (5-pin) male plug M12x1 (4-pin) / metal cable outlet with PVC cable (IP67) cable outlet, cable with ventilation tube (IP68) compact field housing stainless steel 1.4301 (304) customer Mechanical connection G 1 1/2" DIN flush (DIN 3852) Clamp DN 32 (DIN 32676) Clamp DN 50 (DIN 32676) dairy pipe DN 40 (DIN 11851) dairy pipe DN 50 (DIN 11851) Varivent®...

Open the catalog to page 5

All BD|SENSORS GmbH catalogs and technical brochures

  1. DMK 351P

    5 Pages

  2. 18.601 G

    3 Pages

  3. 17.620 G

    3 Pages

  4. DCT 561

    4 Pages

  5. XMD

    5 Pages

  6. DPT 200

    5 Pages

  7. LMP 331I

    4 Pages

  8. EP 500

    4 Pages

Archived catalogs