DL 01 Battery Powered Precision Digital Gauge for Leak Testing Stainless Steel Sensor class 0.05 Nominal pressure The digital pressure gauge DL 01 is a precision device fulfilling highest demands. It was conceived especially for leak testing or pipeline monitoring. from 0 … 100 mbar up to 0 ... 400 bar Special characteristics ► ► data logger graphic display stainless steel housing Ø100 mm In the leakage mode the device shows the pressure decrease during an adjustable time. After finishing of measurement, the result is shown in the display. modular sensor concept Outstanding measuring qualities, an intuitive operation, as well as an integrated data logger characterize the DL 01. In addition, the graphic display provides the handling and the clear presentation of the measuring procedure. accredited calibration certificate according to DKD / DAkkS software incl. USB converter service case with various accessories The gathered data and the relevant information (TAG or serial number, etc.) are recorded and can be read out and processed over the integrated interface via USB and PC software. Preferred areas of use are data logger interval 1 s … 99 days or fixed time default values for time / test duration zero point calibration Plant and machine engineering backlight and much more BD SENSORS GmbH BD-Sensors-Straße 1 D - 95199 Thierstein Pipeline monitoring Leak testing
Open the catalog to page 1DL 01 Precision Digital Gauge for Leak Testing Input pressure Nominal pressure gauge Nominal pressure abs. Overpressure Burst pressure ≥ Nominal pressure gauge / abs. Overpressure Burst pressure ≥ Vacuum resistance Performance Accuracy 1 Long term stability Measuring rate / Display 1 Technical Data nominal pressure pN ≥ 0.4 bar: ≤ ± 0.05 % FSO BFSL nominal pressure pN < 0.4 bar: ≤ ± 0.125 % FSO BFSL ≤ ± 0.1 % FSO / year at reference conditions 1 or 2 measurements per second accuracy according to IEC 60770 – minimum value setting (non-linearity, hysteresis, repeatability) – at room...
Open the catalog to page 2DL 01 Precision Digital Gauge for Leak Testing Technical Data G1/2" EN 837 (pressure transmitter and display separated) G1/2" DIN 3852 with flush sensor 4 G1/2" DIN 3852 open pressure port 4 metrical threads and other variations on request only possible for nominal pressure ranges pN ≤ 40 bar
Open the catalog to page 3DL 01 Precision Digital Gauge for Leak Testing Accessories are not in scope of supply and have to be ordered separately. BD|LOG Software (lite Version) Optionally the software BD|LOG and an interface cable can be ordered. The software is also available for download on our homepage Software (Communication, Configuration): • display of device information (serial number, pressure and temperature range, …) configuration area for all parameters download area for recorded data: - date - pressure value - temperature value actual value Interface cable with integrated USB converter (l: 1.7 m) BD|LOG...
Open the catalog to page 4DL 01 Accessories Technical Data Precision Digital Gauge for Leak Testing Hard-shell service case without accessories Hard shell case. dimension in mm (L x W x H): 432 X 363 X 138 Rubber protection Ordering number: Z1002648 Additional batteries for IS-version use only 3 x 1.5 V / AA Duracell Power Plus (only in combination with service case) Seal set Flat seal copper for mechanical connections according to EN 837 (only in combination with service case) PTFE seal tape Nr. 498.505 Seal tape for mechanical connections material: temperature range: (only in combination with service case) Wrench...
Open the catalog to page 5Ordering code DL 01 1. Position: Digital Display for Precision Digital Pressure Gauge DL 01 DL 01Digital pressure gauge DL 01 with communication interface IS (zone 1) with communication interface IS (zone 0) with communication interface 2. Position: Transmitter for Precision Digital Pressure Gauge DL 01 Version standard version (without explosion protection) IS-version [BFSL] 0.05 % FSO 0.125 % FSO customer Accuracy standard for pN ≥ 0.4 bar standard for pN < 0.4 bar Mechanical connection Special version standard customer Accessories USB converter (incl. software BD|LOG) service case...
Open the catalog to page 6All BD|SENSORS GmbH catalogs and technical brochures
-
data sheet LMK 307 T
5 Pages
-
data sheet DMP 334i
5 Pages
-
data sheet DS 4
4 Pages
-
data sheet DS 202
5 Pages
-
data sheet DMP 335
5 Pages
-
BD|SENSORS at a glance
5 Pages
-
data sheet LMK 806
4 Pages
-
data sheet DM 01
6 Pages
-
data sheet LMK 807
4 Pages
-
data sheet LMP 308 i
5 Pages
-
data sheet LMP 305
5 Pages
-
data sheet LMP 808
4 Pages
-
data sheet LMP 307
5 Pages
-
data sheet LMP 308
5 Pages
-
data sheet LMP 331i
5 Pages
-
date sheet LMP 307i
5 Pages
-
data sheet LMK 808
4 Pages
-
data sheet LMP 331
4 Pages
-
data sheet LMK 858
4 Pages
-
data sheet LMK 809
4 Pages
-
data sheet LMK 458
5 Pages
-
data sheet LMP 307 T
5 Pages
-
data sheet LMK 307
4 Pages
-
data sheet LMK 382
6 Pages
-
data sheet LMK 306
4 Pages
-
data sheet LMK 387
6 Pages
-
data sheet LMK 358 H
5 Pages
-
data sheet LMK 487
5 Pages
-
data sheet LMK 458 H
5 Pages
-
data sheet LMK 358
5 Pages
-
data sheet LMK 382 H
5 Pages
-
datasheet DCT 531i
5 Pages
-
data sheet DS 6
3 Pages
-
data sheet DS 200P
6 Pages
-
data sheet DCL 571
6 Pages
-
data sheet DS 350
5 Pages
-
data sheet BAROLI 02
3 Pages
-
datasheet DMP 336
4 Pages
-
data sheet DS 400
5 Pages
-
data sheet DS 201P
6 Pages
-
data sheet DS 401
5 Pages
-
data sheet DMP 331 Pi
6 Pages
-
data sheet DS 201
6 Pages
-
data sheet BAROLI 05
3 Pages
-
data sheet DS217
3 Pages
-
data sheet DS 200
6 Pages
-
data sheet DMP 457
5 Pages
-
data sheet DS210
5 Pages
-
data sheet DS 230
3 Pages
-
data sheet DMK 331
5 Pages
-
data sheet x|act i
5 Pages
-
data sheet x|act ci
5 Pages
-
data sheet DCT 531
4 Pages
-
data sheet DMP 331
6 Pages
-
data sheet XMP ci
5 Pages
-
data sheet XMP i
6 Pages
-
data sheet DMP 321
6 Pages
-
data sheet DCT 532
5 Pages
-
data sheet DCT 533
4 Pages
-
data sheet DMP i
6 Pages
-
data sheet BAROLI 02P
4 Pages
-
data sheet DS 350P
5 Pages
-
data sheet DS 5
3 Pages
-
data sheet DS 233
5 Pages
-
data sheet LMK 351
4 Pages
-
data sheet DPT 200
10 Pages
-
data sheet DMK 387
5 Pages
-
data sheet DMP 334
4 Pages
-
data sheet DMP 343
5 Pages
-
data sheet DMP 333
6 Pages
-
data sheet 351
5 Pages
-
data sheet DMK 331 P
5 Pages
-
data sheet DMP 339P
4 Pages
-
data sheet DMK 458
5 Pages
-
data sheet DMK 351 P
5 Pages
-
data sheet DMP 331 P
6 Pages
-
data sheet 26.600 G
3 Pages
-
data sheet 17.620 G
3 Pages
-
data sheet iS4
4 Pages
-
data sheet 18.605 G
3 Pages
-
data sheet 30.600 G
3 Pages
-
data sheet 18.601 G
3 Pages
-
data sheet 18.600 G
3 Pages
-
data sheet 17.609 G
3 Pages
-
data sheet 17.600G
3 Pages
-
data sheet DPT 100
4 Pages
-
data sheet DMP 339
5 Pages
-
data sheet DPS 300
5 Pages
-
data sheet DM 10
3 Pages
-
data sheet DMK 457
5 Pages
-
data sheet DMP 320
5 Pages
-
data sheet DPS 200
3 Pages
-
data sheet PA 440
3 Pages
-
data sheet DMD 331
4 Pages
-
datasheet DCT 553P
4 Pages
-
data sheet DMK456
4 Pages
-
datasheet DCT 531P
5 Pages
-
data sheet DCT 562
5 Pages
-
data sheet DCT 563
4 Pages
-
datasheet DCT 533P
4 Pages
-
data sheet DCT 561
4 Pages
-
data sheet DCT 571
5 Pages
-
data sheet LMK 387H
5 Pages
-
Data sheet DMD 831
3 Pages
-
data sheet DS 351
5 Pages
-
data sheet HU 300
5 Pages
-
DMK 351P
5 Pages
-
18.601 G
3 Pages
-
17.620 G
3 Pages
-
DCT 561
4 Pages
-
displays and evaluation devices
44 Pages
-
XMD
5 Pages
-
DPT 200
5 Pages
-
LMP 331I
4 Pages
-
KL 2terminal box plastics
3 Pages
-
KL 1terminal box aluminium
3 Pages
-
EP 500
4 Pages
-
product catalogue overall
48 Pages
-
Piezoelektrische Druckmessung
56 Pages
-
BD|SENSORS at a glance
5 Pages