Catalog excerpts
DCT 571 Industrial Pressure Transmitter with RS485 Modbus RTU Ceramic Sensor accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO Nominal pressure The pressure transmitter DCT 571 was developed for applications in plant and mechanical engineering or in laboratory technology, e.g. designed to measure pressures or levels of pasty, contaminated or aggressive media. from 0 ... 100 mbar up to 0 ... 60 bar Output signal RS485 with Modbus RTU protocol Special characteristic ► high long-term stability reset function The integrated RS 485 interface and the MODBUS RTU protocol used ensure reliable and robust data transmission, which also works smoothly over long distances. different kinds of inch threads The self-developed pressure sensor made of 99.9% pure ceramic is characterized by a high overload capacity, as well as temperature and media resistance. pressure port in PVDF or PP-HT for aggressive media on request Preferred areas of use Plant and machine engineering Laboratory techniques Water Aggressive media BD SENSORS GmbH BD-Sensors-Straße 1 D - 95199 Thierstein Telefon Telefax www.bdsensors.de info@bdse
Open the catalog to page 1DCT 571 Industrial Pressure Transmitter with RS485 Modbus RTU Input pressure range Nominal pressure gauge Level Overpressure Burst pressure ≥ Permissible vacuum Output signal Digital (pressure) Supply Direct current (DC) Performance Accuracy 1 Long term stability Measuring rate Delay time 1 RS485 with Modbus RTU protocol VS = 9 … 32 VDC standard: ≤ ± 0.35 % FSO option: ≤ ± 0.25 % FSO ≤ ± 0,1 % FSO / year at reference conditions 500 Hz 500 msec accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability) Thermal effects (offset and span) Tolerance band...
Open the catalog to page 2DCT 571 Industrial Pressure Transmitter with RS485 Modbus RTU Technical Data Wiring diagram Modbus RTU supply + Pin configuration / electrical connection Electrical connection Supply + Shield Dimensions / mechanical connection (mm / in) standard plug housing G1/2" DIN 3852 with male plug M12x1 metric threads and other versions on request
Open the catalog to page 3DCT 571 Industrial Pressure Transmitter with RS485 Modbus RTU Technical Data Configuration Modbus RTU Standard configuration Address Parity None Odd Even Configuration code (to specify with order) www.bdsensors.de info@bdsensors.de © 2020 BD|SENSORS GmbH - The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials.
Open the catalog to page 4Output RS485 Modbus RTU Accuracy standard option Electrical connection male plug M12x1 (5-pin) / metal customer Mechanical connection G1/2" DIN 3852 G1/2" EN 837 G1/4" DIN 3852 G1/4" EN 837 G3/4" with flush sensor customer Seal FKM EPDM FFKM customer Pressure port stainless steel 1.4404 (316L) PVDF PP-HT customer Diaphragm ceramics Al2O3 99,9 % customer Special version standard customer consult consult consult C 9 metric threads and others on request only for mechanical connection G3/4"; for pressure port in PVDF or PP-HT the operation medium temperature is -30 … 60 °C © 2020 BD|SENSORS...
Open the catalog to page 5All BD|SENSORS GmbH catalogs and technical brochures
-
data sheet DCT 541
4 Pages
-
data sheet DMP 333P
5 Pages
-
data sheet DPT 200
10 Pages
-
data sheet LMK 809
4 Pages
-
data sheet DMP 334i
5 Pages
-
data sheet DS 202
5 Pages
-
data sheet LMK 351
4 Pages
-
data sheet DS 214
5 Pages
-
data sheet DS 233
5 Pages
-
data sheet DS 201
6 Pages
-
data sheet DS 200
6 Pages
-
data sheet LMP 331i
5 Pages
-
data sheet DMP i
6 Pages
-
data sheet DMP 331 Pi
6 Pages
-
data sheet DMP 331 P
6 Pages
-
data sheet DS 201P
6 Pages
-
data sheet LMK 806
4 Pages
-
data sheet DS 200P
6 Pages
-
data sheet DS210
5 Pages
-
data sheet DMP 335
5 Pages
-
data sheet LMK 307 T
5 Pages
-
data sheet DS 4
4 Pages
-
BD|SENSORS at a glance
5 Pages
-
data sheet DL 01
6 Pages
-
data sheet DM 01
6 Pages
-
data sheet LMK 807
4 Pages
-
data sheet LMP 308 i
5 Pages
-
data sheet LMP 305
5 Pages
-
data sheet LMP 808
4 Pages
-
data sheet LMP 307
5 Pages
-
data sheet LMP 308
5 Pages
-
date sheet LMP 307i
5 Pages
-
data sheet LMK 808
4 Pages
-
data sheet LMP 331
4 Pages
-
data sheet LMK 858
4 Pages
-
data sheet LMK 458
5 Pages
-
data sheet LMP 307 T
5 Pages
-
data sheet LMK 307
4 Pages
-
data sheet LMK 382
6 Pages
-
data sheet LMK 306
4 Pages
-
data sheet LMK 387
6 Pages
-
data sheet LMK 358 H
5 Pages
-
data sheet LMK 487
5 Pages
-
data sheet LMK 458 H
5 Pages
-
data sheet LMK 358
5 Pages
-
data sheet LMK 382 H
5 Pages
-
datasheet DCT 531i
5 Pages
-
data sheet DS 6
3 Pages
-
data sheet DCL 571
6 Pages
-
data sheet DS 350
5 Pages
-
data sheet BAROLI 02
3 Pages
-
datasheet DMP 336
4 Pages
-
data sheet DS 400
5 Pages
-
data sheet DS 401
5 Pages
-
data sheet BAROLI 05
3 Pages
-
data sheet DS217
3 Pages
-
data sheet DMP 457
5 Pages
-
data sheet DS 230
3 Pages
-
data sheet DMK 331
5 Pages
-
data sheet x|act i
5 Pages
-
data sheet x|act ci
5 Pages
-
data sheet DCT 531
4 Pages
-
data sheet DMP 331
6 Pages
-
data sheet XMP ci
5 Pages
-
data sheet XMP i
6 Pages
-
data sheet DMP 321
6 Pages
-
data sheet DCT 532
5 Pages
-
data sheet DCT 533
4 Pages
-
data sheet BAROLI 02P
4 Pages
-
data sheet DS 350P
5 Pages
-
data sheet DS 5
3 Pages
-
data sheet DMK 387
5 Pages
-
data sheet DMP 334
4 Pages
-
data sheet DMP 343
5 Pages
-
data sheet DMP 333
6 Pages
-
data sheet 351
5 Pages
-
data sheet DMK 331 P
5 Pages
-
data sheet DMP 339P
4 Pages
-
data sheet DMK 458
5 Pages
-
data sheet DMK 351 P
5 Pages
-
data sheet 26.600 G
3 Pages
-
data sheet 17.620 G
3 Pages
-
data sheet iS4
4 Pages
-
data sheet 18.605 G
3 Pages
-
data sheet 30.600 G
3 Pages
-
data sheet 18.601 G
3 Pages
-
data sheet 18.600 G
3 Pages
-
data sheet 17.609 G
3 Pages
-
data sheet 17.600G
3 Pages
-
data sheet DPT 100
4 Pages
-
data sheet DMP 339
5 Pages
-
data sheet DPS 300
5 Pages
-
data sheet DM 10
3 Pages
-
data sheet DMK 457
5 Pages
-
data sheet DMP 320
5 Pages
-
data sheet DPS 200
3 Pages
-
data sheet PA 440
3 Pages
-
data sheet DMD 331
4 Pages
-
datasheet DCT 553P
4 Pages
-
data sheet DMK456
4 Pages
-
datasheet DCT 531P
5 Pages
-
data sheet DCT 562
5 Pages
-
data sheet DCT 563
4 Pages
-
datasheet DCT 533P
4 Pages
-
data sheet DCT 561
4 Pages
-
data sheet LMK 387H
5 Pages
-
Data sheet DMD 831
3 Pages
-
data sheet DS 351
5 Pages
-
data sheet HU 300
5 Pages
-
DMK 351P
5 Pages
-
18.601 G
3 Pages
-
17.620 G
3 Pages
-
DCT 561
4 Pages
-
displays and evaluation devices
44 Pages
-
XMD
5 Pages
-
DPT 200
5 Pages
-
LMP 331I
4 Pages
-
KL 2terminal box plastics
3 Pages
-
KL 1terminal box aluminium
3 Pages
-
EP 500
4 Pages
-
product catalogue overall
48 Pages
-
Piezoelektrische Druckmessung
56 Pages
-
BD|SENSORS at a glance
5 Pages