1. Catalogs
  2. BD|SENSORS GmbH
  3. data sheet 18.601 G

data sheet 18.601 G

data sheet 18.601 G

data sheet 18.601 G

Product catalog summary
Overview: The document provides technical specifications for the BD SENSORS 18.601 G OEM Pressure Transmitter, designed for low-pressure applications in general industrial settings.
Specifications:
  • Sensor Type: Piezoresistive stainless steel sensor.
  • Accuracy: 0.5% FSO for pressures above 160 mbar, 1% FSO for pressures at or below 160 mbar, according to IEC 60770.
  • Pressure Range: Nominal pressure ranges from 0 to 100 mbar up to 0 to 6 bar.
  • Overpressure and Burst Pressure: Overpressure ranges from 1 to 21 bar, and burst pressure is at least 1.5 to 35 bar.
  • Output Signal: Standard 2-wire (4-20 mA) and optional 3-wire configurations (0-10 V and ratiometric).
Performance:
  • Response Time: 2-wire: ≤ 10 msec, 3-wire: ≤ 3 msec.
  • Long-term Stability: ≤ ± 0.2% FSO per year.
  • Thermal Error: ≤ ± 0.3% FSO per 10 K in the compensated range of 0 to 70°C.
Environmental and Mechanical Specifications:
  • Temperature Range: Medium: -25 to 125°C, Electronics/Environment: -25 to 85°C, Storage: -40 to 85°C.
  • Vibration and Shock Resistance: Vibration: 10 g, 25 Hz to 2 kHz; Shock: 100 g / 1 msec.
Materials and Construction:
  • Pressure Port/Housing: Stainless steel 1.4301 (304).
  • Seals: FKM.
  • Diaphragm: Stainless steel 1.4435 (316 L).
Electrical Protection:
  • Short-circuit Protection: Permanent for 3-wire ratiometric.
  • Reverse Polarity Protection: No damage but no function.
  • EMC Compliance: According to EN 61326.
Miscellaneous:
  • Weight: Approximately 120 g.
  • Operational Life: 100 million load cycles.
  • CE Conformity: EMC Directive 2014/30/EU.
See more

Catalog excerpts

data sheet 18.601 G-1

18.601 G OEM Pressure Transmitter Low Pressure Applications ► general industrial applications piezoresistive stainless steel sensor accuracy 0.5 % FSO according to IEC 60770 nominal pressure ranges from 0 … 100 mbar up to 0 … 6 bar Technical Data Input pressure range Nominal pressure gauge Overpressure Burst pressure ≥ Vacuum resistance Output signal / Supply Standard Options 3-wire Performance Accuracy1 Permissible load Influence effects Response time Long term stability Measuring rate 1 pN > 160 mbar: ≤ ± 0.5 % FSO pN ≤ 160 mbar: ≤ ± 1 % FSO 2-wire: Rmax = [(VS – VS min) / 0.02 A]  supply: 0.05 % FSO / 10 V 2-wire: ≤ 10 msec ≤ ± 0,2 % FSO / year at reference conditions 1 kHz accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability) Thermal effects (offset and span) / Permissible temperatures Thermal error ≤ ± 0.3 % FSO / 10 K in compensated range 0 ... 70 °C Permissible temperatures medium: -25 … 125 °C electronics / environment: -25 ... 85 °C Electrical protection Short-circuit protection permanent 3-wire ratiometric: none Reverse polarity protection no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 61326 Mechanical stability 10 g, 25 Hz … 2 kHz according to DIN EN 60068-2-6 Vibration Shock 100 g / 1 msec according to DIN EN 60068-2-27 BD SENSORS GmbH BD-Sensors-Straße 1 D - 95199 Thierstein

 Open the catalog to page 1
data sheet 18.601 G-2

18.601 G OEM Pressure Transmitter Low Pressure Materials Pressure port / housing Seals Diaphragm Media wetted parts Miscellaneous Weight Current consumption Technical Data approx. 120 g 2-wire: max. 25 mA 3-wire ratiometric: typ. 1.5 mA 3-wire voltage: max. 7 mA (short circuit current: max. 20 mA) 100 million load cycles EMC Directive: 2014/30/EU Operational life CE-conformity Wiring diagrams 2-wire-system (current) Pin configuration Electrical connection Supply + Supply – Signal + (for 3-wire) Shield cable colours (IEC 60757) WH (white) BN (brown) GN (green) GNYE (green-yellow) Electrical connections...

 Open the catalog to page 2
data sheet 18.601 G-3

Ordering code 18.601 G 18.601 G Input Pressure gauge 4 … 20 mA / 2-wire 0 … 10 V / 3-wire 10 … 90% of VS / 3-wire ratiometric customer Accuracy PN > 160 mbar: ≤ ± 0.5 % FSO ≤ ± 1 % FSO PN ≤ 160 mbar: customer Electrical connection male and female plug ISO 4400 male plug M12x1 (4-pin), metal cable outlet with 2 m PVC cable customer Mechanical connection G1/4" DIN 3852 G1/4" EN 837 1/4" NPT G1/2" EN 837 customer Seals FKM customer Special version standard customer standard: 2 m PVC cable without ventilation tube (permissible temperature: -5 … 70 °C) BD SENSORS GmbH BD-Sensors-Straße 1 D - 95199...

 Open the catalog to page 3

All BD|SENSORS GmbH catalogs and technical brochures

  1. DMK 351P

    5  Pages

  2. 18.601 G

    3  Pages

  3. 17.620 G

    3  Pages

  4. DCT 561

    4  Pages

  5. XMD

    5  Pages

  6. DPT 200

    5  Pages

  7. LMP 331I

    4  Pages

  8. EP 500

    4  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.