119B - 1

Model 119B Diaphragm-Type Force Transducers Description Model 119B is a diaphragm-type force transducer which is designed to measure either tension or compression force. To do this, the 119B transducer has two threads at its top and bottom, respectively, which provide connections when this transducer is installed for application. The diaphragm-type design enables the 119B transducers to have higher resistance to eccentric loading, compared to the S-type force transducers. In order to be easily integrated into an existing system, the 119B features a compact structure. In consideration of outdoor application, this 119B transducer possesses a fully welded structure which makes it suitable for environment protection up to IP68. Thanks to advanced strain gauge technology from BCM SENSOR, the 119B force transducers can deliver stable measuring results of precision up to 0.5%fs. On request, the 119B transducer can be integrated with a TEDS (transducer electronic data sheet) chip inside its housing, by which it can be easily re-calibrated on site without using conventional calibration facility. - environment protection: up to IP68 - convenient installation - TEDS available on request - accuracy up to 0.5%fs - compact design - force measurement or monitoring in process control - automotive components and systems - material test BCM SENSOR TECHNOLOGIES BVBA Industriepark Zone 4, Brechtsebaan 2 website: www.bcmsensor.com B-2900 Schoten - Antwerpen, BELGIUM email: sales@bcmsensor.com

Open the catalog to page 1
119B - 2

Electrical Connection Technical Data Parameters Notes: 1. “fs” refers to full scale pressure. 2. Accuracy = sqrt (non-linearity2 + hysteresis2 + repeatability2). 3. Calculated as a rate of output change between -10°C and +60°C, and normalized by the output at room temperature (25°C). Industriepark Zone 4, Brechtsebaan 2 B-2900 Schoten - Antwerpen, BELGIUM website: www.bcmsensor.com email: sales@bcmsensor.com

Open the catalog to page 2
119B - 3

Ordering Information 3kN pos. 3: output sensitivity 0.9mV/V: in case of capacity 50N, ..., 500N 1.8mV/V: in case of capacity 1kN, ..., 5kN |pos. 4: accuracy 1%fs: in case of capacity 50N, ..., 500N 0.5%fs: in case of capacity 1kN, ..., 5kN pos. 5: bridge resistance 350Q pos. 6: mechanical interface M4: in case of capacity 50N, ..., 500N M8: in case of capacity 1kN, ..., 5kN M12: in case of capacity 10kN pos. 7: electrical interface 2/4/PVC/0.5 = 02mm, 4-core shielded, PVC, cable length = 0.5m(#) (#): Cable length can be customized on request. pos. 8: environment protection I IP67 (standard)...

Open the catalog to page 3

All BCM SENSOR TECHNOLOGIES bv catalogs and technical brochures

  1. model 328s

    2 Pages

  2. 664F(C)

    3 Pages

  3. 101B(A19F)

    4 Pages

  4. 101B(A12.6H)

    4 Pages

  5. 101B(a19L)

    4 Pages

  6. Model 1811

    3 Pages

  7. 153T

    3 Pages

  8. 670F

    3 Pages

  9. 725F

    4 Pages

  10. FD101

    3 Pages

  11. Model 1531

    3 Pages

  12. Model 1815

    2 Pages

  13. Model 181 1

    3 Pages

  14. Model A3

    2 Pages

  15. Model A2

    2 Pages

  16. Model T3000

    5 Pages

  17. Model 1661

    3 Pages

  18. Model 1660

    3 Pages

  19. Model L V38

    2 Pages

  20. Model L V39

    3 Pages

  21. Model L V37

    1 Pages

  22. Model L V36

    3 Pages

  23. Model L V35

    1 Pages

  24. Model L V16

    3 Pages

  25. Model 301B

    4 Pages

  26. Model 500G

    4 Pages

  27. Model 330B

    3 Pages

  28. Model SE106

    3 Pages

  29. Model SE105

    3 Pages

  30. Model SE103

    4 Pages

  31. Model SE102

    4 Pages

  32. Model SE101

    3 Pages