Model 119B Diaphragm-Type Force Transducers Description Model 119B is a diaphragm-type force transducer which is designed to measure either tension or compression force. To do this, the 119B transducer has two threads at its top and bottom, respectively, which provide connections when this transducer is installed for application. The diaphragm-type design enables the 119B transducers to have higher resistance to eccentric loading, compared to the S-type force transducers. In order to be easily integrated into an existing system, the 119B features a compact structure. In consideration of outdoor application, this 119B transducer possesses a fully welded structure which makes it suitable for environment protection up to IP68. Thanks to advanced strain gauge technology from BCM SENSOR, the 119B force transducers can deliver stable measuring results of precision up to 0.5%fs. On request, the 119B transducer can be integrated with a TEDS (transducer electronic data sheet) chip inside its housing, by which it can be easily re-calibrated on site without using conventional calibration facility. - environment protection: up to IP68 - convenient installation - TEDS available on request - accuracy up to 0.5%fs - compact design - force measurement or monitoring in process control - automotive components and systems - material test BCM SENSOR TECHNOLOGIES BVBA Industriepark Zone 4, Brechtsebaan 2 website: www.bcmsensor.com B-2900 Schoten - Antwerpen, BELGIUM email: [email protected]
Open the catalog to page 1Electrical Connection Technical Data Parameters Notes: 1. “fs” refers to full scale pressure. 2. Accuracy = sqrt (non-linearity2 + hysteresis2 + repeatability2). 3. Calculated as a rate of output change between -10°C and +60°C, and normalized by the output at room temperature (25°C). Industriepark Zone 4, Brechtsebaan 2 B-2900 Schoten - Antwerpen, BELGIUM website: www.bcmsensor.com email: [email protected]
Open the catalog to page 2Ordering Information 3kN pos. 3: output sensitivity 0.9mV/V: in case of capacity 50N, ..., 500N 1.8mV/V: in case of capacity 1kN, ..., 5kN |pos. 4: accuracy 1%fs: in case of capacity 50N, ..., 500N 0.5%fs: in case of capacity 1kN, ..., 5kN pos. 5: bridge resistance 350Q pos. 6: mechanical interface M4: in case of capacity 50N, ..., 500N M8: in case of capacity 1kN, ..., 5kN M12: in case of capacity 10kN pos. 7: electrical interface 2/4/PVC/0.5 = 02mm, 4-core shielded, PVC, cable length = 0.5m(#) (#): Cable length can be customized on request. pos. 8: environment protection I IP67 (standard) IP68...
Open the catalog to page 33 Pages
2 Pages
3 Pages
4 Pages
4 Pages
4 Pages
3 Pages
3 Pages
3 Pages
1 Page
3 Pages
3 Pages
4 Pages
3 Pages
3 Pages
3 Pages
3 Pages
2 Pages
3 Pages
2 Pages
2 Pages
5 Pages
3 Pages
3 Pages
3 Pages
5 Pages
3 Pages
3 Pages
3 Pages
4 Pages
2 Pages
3 Pages
1 Page
3 Pages
1 Page
3 Pages
6 Pages
4 Pages
4 Pages
4 Pages
3 Pages
3 Pages
4 Pages
4 Pages
3 Pages
3 Pages
3 Pages
4 Pages
4 Pages
3 Pages
2 Pages