Model 119B Diaphragm-Type Force Transducers Description Model 119B is a diaphragm-type force transducer which is designed to measure either tension or compression force. To do this, the 119B transducer has two threads at its top and bottom, respectively, which provide connections when this transducer is installed for application. The diaphragm-type design enables the 119B transducers to have higher resistance to eccentric loading, compared to the S-type force transducers. In order to be easily integrated into an existing system, the 119B features a compact structure. In consideration of outdoor application, this 119B transducer possesses a fully welded structure which makes it suitable for environment protection up to IP68. Thanks to advanced strain gauge technology from BCM SENSOR, the 119B force transducers can deliver stable measuring results of precision up to 0.5%fs. On request, the 119B transducer can be integrated with a TEDS (transducer electronic data sheet) chip inside its housing, by which it can be easily re-calibrated on site without using conventional calibration facility. - environment protection: up to IP68 - convenient installation - TEDS available on request - accuracy up to 0.5%fs - compact design - force measurement or monitoring in process control - automotive components and systems - material test BCM SENSOR TECHNOLOGIES BVBA Industriepark Zone 4, Brechtsebaan 2 website: www.bcmsensor.com B-2900 Schoten - Antwerpen, BELGIUM email: sales@bcmsensor.com
Open the catalog to page 1
Electrical Connection Technical Data Parameters Notes: 1. “fs” refers to full scale pressure. 2. Accuracy = sqrt (non-linearity2 + hysteresis2 + repeatability2). 3. Calculated as a rate of output change between -10°C and +60°C, and normalized by the output at room temperature (25°C). Industriepark Zone 4, Brechtsebaan 2 B-2900 Schoten - Antwerpen, BELGIUM website: www.bcmsensor.com email: sales@bcmsensor.com
Open the catalog to page 2
Ordering Information 3kN pos. 3: output sensitivity 0.9mV/V: in case of capacity 50N, ..., 500N 1.8mV/V: in case of capacity 1kN, ..., 5kN |pos. 4: accuracy 1%fs: in case of capacity 50N, ..., 500N 0.5%fs: in case of capacity 1kN, ..., 5kN pos. 5: bridge resistance 350Q pos. 6: mechanical interface M4: in case of capacity 50N, ..., 500N M8: in case of capacity 1kN, ..., 5kN M12: in case of capacity 10kN pos. 7: electrical interface 2/4/PVC/0.5 = 02mm, 4-core shielded, PVC, cable length = 0.5m(#) (#): Cable length can be customized on request. pos. 8: environment protection I IP67 (standard)...
Open the catalog to page 3All BCM SENSOR TECHNOLOGIES bv catalogs and technical brochures
-
EPS200-series
3 Pages
-
model 328s
2 Pages
-
664F(C)
3 Pages
-
101B(A19F)
4 Pages
-
101B(A12.6H)
4 Pages
-
101B(a19L)
4 Pages
-
Model 101B (a19D)
3 Pages
-
Model 1966/1996
3 Pages
-
Model 1811
3 Pages
-
WD 21 Weighing indicator
1 Pages
-
153T
3 Pages
-
670F
3 Pages
-
725F
4 Pages
-
FD101
3 Pages
-
Model 1531
3 Pages
-
Model 2 9 6 5
3 Pages
-
M o d e l 1 9 1 6 / 1 9 9 6
3 Pages
-
Model 1815
2 Pages
-
Model 181 1
3 Pages
-
Model A3
2 Pages
-
Model A2
2 Pages
-
Model T3000
5 Pages
-
model 3911/3991
3 Pages
-
Model 1661
3 Pages
-
Model 1660
3 Pages
-
Semiconductor Strain Gauges
5 Pages
-
Model TFS2100
3 Pages
-
Model TFS2200
3 Pages
-
Model TFS2000
3 Pages
-
Model L V66(a)/L V66(b)
4 Pages
-
Model L V38
2 Pages
-
Model L V39
3 Pages
-
Model L V37
1 Pages
-
Model L V36
3 Pages
-
Model L V35
1 Pages
-
Model L V16
3 Pages
-
Model 101B(f)
6 Pages
-
Model 101B(a15G)
4 Pages
-
Model 101B(a13H)
4 Pages
-
Model 101B(a12.6L)
4 Pages
-
Model 664F(b)
3 Pages
-
Model 664F(a)
3 Pages
-
Model 301B
4 Pages
-
Model 500G
4 Pages
-
Model 330B
3 Pages
-
Model SE106
3 Pages
-
Model SE105
3 Pages
-
Model SE103
4 Pages
-
Model SE102
4 Pages
-
Model SE101
3 Pages
-
BCM Load Cells
2 Pages