Series 500

Series 500

Series 500

Product catalog summary
Introduction
The MOVISTROB® Series 500 products are subjected to stringent quality and functionality tests to ensure they meet safety and performance standards. Users are advised to read the operating instructions carefully to avoid damage or injury from improper use.
General Description
The MOVISTROB® 500.00 is a stroboscope designed for analyzing rapid periodic motions through short light flashes. It features high flash frequency, stability, accuracy, and ease of use with minimal maintenance costs. The flash rate is adjustable from 150 to 60000 flashes per minute, and the device is compact and durable.
Controls and Indicators
The stroboscope includes various controls such as the "ON" pushbutton, flash frequency range selector, control knob for flash rate adjustment, and inputs for external control. It also features a Xenon gas discharge tube for efficient lighting and options for internal and external synchronization.
General Instructions
To operate, connect the stroboscope to the specified AC line and switch it on. Use the "Int. Trig" button for internal control and adjust the flash rate with the control knob. For external control, use the "Ext. Trig." button and connect a pulse generator.
Stroboscopic Principle
Stroboscopy enables the observation of high-speed periodic motion by illuminating the object with brief light flashes, making it appear stationary or in slow motion at the correct flash frequency.
Measurement of RPM and Frequencies
To measure RPM, identify the highest flash frequency that results in a stopped image or calculate using two neighboring flash frequencies.
Slow-Motion Cycle
If the flash frequency slightly deviates from a whole-number multiple of the rotation time, the object appears to rotate slowly, allowing detailed observation.
Angular Speed and Apparent Rotation
The relationship between true angular speed and apparent angular speed is discussed, with apparent rotation speed increasing as the deviation from true speed increases.
Stopped Images of Phantom Objects
Stopped images occur at specific flash frequencies, resulting in phantom objects. These images are clearer with lower values of n and k.
Objects with Finite Rotational Symmetry
For symmetrical objects, stopped images result from specific timing, with phantom images forming regular patterns.
Replacing Flash Tube and Fuses
If flash failures occur, replace the flash tube after ensuring the device is off and unplugged. Allow the bulb to cool before replacement. Replace the fuse if necessary.
Maintenance and Repair
If the instrument is unsafe, it should be removed from operation. Repairs and calibration should be conducted by trained personnel or returned to the manufacturer.
Technical Specifications
The Model 500.00 features a Xenon high-efficiency white light tube with a light intensity of approximately 750 lux and a flash duration of 2 - 7 µs. The flash-rate range is 2.5 - 1000 flashes/sec. It includes a phase shifter, line synchronization, and a BNC outlet for digital counters. The device is housed in sheet-steel with a carrying handle and weighs 2.8 kg. Special accessories are available, including a carrying box, red filter, hand lamp, magnifying strobe lamp, infrared sensor, electromagnetic induction pickup, telescopic tripod, and protective spectacles.
See more

Catalog excerpts

Series 500 -1

table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:11.00pt "Times New Roman", serif; } .font1 { font:15.00pt "Times New Roman", serif; } .font2 { font:20.00pt "Times New Roman", serif; } .font3 { font:23.00pt "Times New Roman", serif; } .font4 { font:31.00pt "Times New Roman", serif; } .font5 { font:21.00pt "Verdana", sans-serif; } Bamberg + Bormann ELECTRONIC GmbH INSTRUCTION MANU AL MOVISTROB* Sries 500 Type 500.00 BBK Bainberg i lormanii Electronic GmbH WiebelsheidestraBe 45 D 59757 Araberg / Neheim Hfhtcn Tel.: 0049(0)2932 547760 Fax: 0049 (0)2932 34675 ]Jiii-i'Dft: http://www.bbcelccIiouic.dee-mail: info@bhe cIeclronic.de

 Open the catalog to page 1
Series 500 -2

table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:11.00pt "Arial", sans-serif; } .font1 { font:5.00pt "Times New Roman", serif; } .font2 { font:11.00pt "Times New Roman", serif; } .font3 { font:14.00pt "Times New Roman", serif; } L Introduclinn Each MOVISTROB* product lias to pass ihrough various controls during ils production phases and must also undergo very strict and conscientious function and qnality tests beforc Icaving the factory for dclivery to our clients. Wc can assure you that the MOVISTROB* product you rcccivcd is in strict confornty with our high quahty...

 Open the catalog to page 2
Series 500 -3

table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:11.00pt "Arial", sans-serif; } .font1 { font:13.00pt "Arial", sans-serif; } .font2 { font:10.00pt "Times New Roman", serif; } .font3 { font:11.00pt "Times New Roman", serif; } .font4 { font:12.00pt "Times New Roman", serif; } .font5 { font:14.00pt "Times New Roman", serif; } .font6 { font:15.00pt "Times New Roman", serif; } Do not jillrju liquida or met allie objecta lo enter the ventilation holes on tbe stroboscope as Ibis ma y cause permanent damage. The instrument ma y be operated by tratned personnel only» Maintenance...

 Open the catalog to page 3
Series 500 -4

table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:11.00pt "Arial", sans-serif; } .font1 { font:10.00pt "Times New Roman", serif; } .font2 { font:11.00pt "Times New Roman", serif; } .font3 { font:12.00pt "Times New Roman", serif; } .font4 { font:14.00pt "Times New Roman", serif; } .font5 { font:15.00pt "Times New Roman", serif; } an external current source. When triggerc I by external current the flash is triegered along the positively-directed edge of an impulse. Tbe impulse current (maximum) should not exceed 100 V. Tbe response cycle lies at 2,5 V (TTL). < aution:...

 Open the catalog to page 4
Series 500 -5

table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:13.00pt "Arial", sans-serif; } .font1 { font:9.00pt "Times New Roman", serif; } .font2 { font:11.00pt "Times New Roman", serif; } .font3 { font:14.00pt "Times New Roman", serif; } .font4 { font:15.00pt "Times New Roman", serif; } 4.1 Opration with Internai Control Tbe h km coniiuon mode of opration is to coutrol the flash rate by the internai flash frequency generator To actuatc this program press pushbutton "Int. Trig" (7). Thcn set the desired flash rate range by pressing range sclcclor pushbutton 驄3*\ and makc the...

 Open the catalog to page 5
Series 500 -6

table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:11.00pt "Arial", sans-serif; } .font1 { font:7.00pt "Times New Roman", serif; } .font2 { font:11.00pt "Times New Roman", serif; } .font3 { font:12.00pt "Times New Roman", serif; } .font4 { font:14.00pt "Times New Roman", serif; } .font5 { font:15.00pt "Times New Roman", serif; } .font6 { font:16.00pt "Times New Roman", serif; } 5.2 Mcasurcmcnt of RPM and Frequencies To mcasurc the RPM v cilbcr the highest flash frequency fl - v which rcsults in a stopped image oi ihc object can bc determined, or two ncighboiiring flash...

 Open the catalog to page 6
Series 500 -7

table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:21.00pt "Arial", sans-serif; } .font1 { font:14.00pt "Times New Roman", serif; } .font2 { font:15.00pt "Times New Roman", serif; } Stopped images of the rcal object therefore resuit from T = (n + k)r and/or f = (k*n)\\ In addition, stopped images of phantom objeets also occur for T=(n+ k) (r + m)and/or r=(k + n)(m*v) (k« in, n are whole numbers). If k and n are selected relatively-prime. k.m marks appear in the corners of a rcgular k.m-angle. 6, Repliuing Thish l'ubկ itntl Fuses If there is repeated flash faiiure or...

 Open the catalog to page 7
Series 500 -8

table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:11.00pt "Arial", sans-serif; } .font1 { font:10.00pt "Georgia", serif; } .font2 { font:14.00pt "Times New Roman", serif; } .font3 { font:15.00pt "Times New Roman", serif; } .font4 { font:31.00pt "Times New Roman", serif; } Il rcchnical Spcifications vimici 500.00 Flash lubc: Light iiitcnsity: Flash durt ion: Flash-rate range X颩non high-cfficicncy while hght tube 4-pin plug in type, model MS.500. approx. 750 lux approx. 2 - 7 (is 2.5 - 1000 flashes/sec. = Hz quivalent to 150 - 60000 flasbes/min = RPM in three overlapping...

 Open the catalog to page 8
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.