Typical Applications:
  • Tank and silo weighing
  • Compressive and tensile tests
  • Force measurement
  • Strength measurement
  • Process control applications
  • Dosing systems
Fast and Accurate Output:
  • Up to 800 conversions per second
  • Programmable adaptive digital filter
  • Internal resolution up to 16,000,000
  • Analogue output resolution up to 60,000
  • Very low zero and gain drift with temperature changes
  • Minimal long-term drift
Analog Output Features:
  • Bipolar load cell signal input for force measurement
  • 6-wire load cell connection for high accuracy
  • Two relay contact cutoff outputs and one zeroing input
  • Bipolar analogue voltage output
Product Overview:

The TX13 analog load cell transmitter converts load cell signals to analog output quickly and accurately. It features a programmable smart filter to minimize environmental vibration, providing a filtered signal for weight and force measurement systems. The high-quality analog and digital hardware ensures stability and eliminates zero and span drifts caused by temperature changes.

Analogue output options include 4-20 mA, 0-20 mA, 0-10 V, and 0-5 V, with the TX13 MB model offering an additional -10 to 10 V range. Instruments are normalized and matched during production for direct replacement and high accuracy in electronic calibration (eCAL).

The device includes two cutoff outputs for alarms or control valves and a digital input for zeroing the scale.

Specifications:
  • Analogue output: 4-20 mA, 0-20 mA, 0-10 VDC, or 0-5 V
  • TX13 MB additional output: bipolar -10 to +10 V
  • 16-bit high-resolution DAC with very low drift
  • Up to 800 conversions per second
  • Load cell signal range: -18 mV to +18 mV
  • Minimum load cell signal range: < 0.8 mV
  • Linearity: < 0.01%
  • Temperature drift: < 0.005% FSR/°C
  • Internal resolution: up to 16,000,000 counts
  • Digital filter: 9-step adjustable smart and adaptive filter
  • Calibration: via test weight or electronic calibration (eCal)
  • Power supply: 12-28 VDC (TX13), 9-28 VDC (TX13 MB)
  • Enclosure: Polyamide, DIN-rail mount, IP20
  • Operating temperature: -15°C to +55°C
  • Humidity: 85% RH max, non-condensing
Contact Information:

Tuzla Kimya Sanayicileri O.S.B Organik Cad. No:31 34953 Tuzla, Istanbul - Turkey

Phone: +90 216 593 26 30

Email: [email protected]

Website: baykon.com

See more

Catalog excerpts

Baykon TX13 Load Cell Transmitters-1

TX13 Analogue Load Cell Transmitter High speed and precise analogue output Fast and Accurate Output • Up to 800 conversion per second • Programmable adaptive digital filter • Up to 16 000 000 internal resolution • Up to 60 000 analogue output resolution • Very low zero and gain drift at temperature changes. • Very low drift in long term. Analog Output With • Bipolar load cell signal input for force measurement • 6 wire load cell connection for high accuracy • 2 pcs relay contact cutoff outputs and one zeroing input • Bipolar analogue voltage output Typical Applications • Tank and silo weighing • Compressive and tensile tests • Force measurement • Strength measurement • Process control applications • Dosing systems TX13 analog load cell transmitter converts load cell signal to analog output very fast and accurately. Programmable smart filter of TX13 minimizes the environmental vibration to produce the best filtered signal to your PLC for your weight and force measurement systems. Its high quality analog & digital hardware eliminates zero and span drifts caused by temperature changes and provides perfect stability for long term unlike traditional analogue transmitters. Analogue output is programmable as 4-20 mA, 0-20 mA, 0-10 V, 0-5 V. TX13 MB has additionally -10 to 10 V analog output range. All instruments are normalized and matched in the production for direct replicement when calibration done at the PLC side and to provide highest accuracy for electronic calibration (eCAL). 2 cut off outputs can be used for alarm or control valves; one digital input

 Open the catalog to page 1
Baykon TX13 Load Cell Transmitters-2

D/A convertion Analogue output resolution Analogue output update rate Load Cell Signal Load cell signal range Minimum load cell signal range Linearity Temperature drift A/D converter Internal resolution Weighing Calibration with test weight eCal electronic calibration Fast calibration Digital filter Zeroing Set points Load Cells Excitation Number of load cells Connection Serial Interface RS-232C Power Power supply 4-20 mA, 0-20 mA, 0-10 VDC or 0-5 V TX13 MB has additionally bipolar -10 to +10 V output. 16 bit high resolution and very low drift DAC Up to 60 000 steps. Up to 800 conversion per second....

 Open the catalog to page 2

All BAYKON Industrial Weighing Systems catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.