Typical Applications
  • Tank and silo weighing
  • Compressive and tensile tests
  • Force measurement
  • Strength measurement
  • Process control applications
  • Dosing systems
System Integration
  • Supports analogue outputs: 4-20 mA, 0-20 mA, 0-10 V, or 0-5 V
  • Features normalised, matched, and high-resolution analogue outputs
  • Calibration can be performed at the PLC side with default adjustments
  • Includes 2 relay contact outputs
  • Minimized long-term drifts
eCal - Electronic Calibration
  • Calibration without test weights via RS-232C port
  • Advantageous for heavy capacity tank, silo, and hopper scale calibration
  • High accuracy due to instrument’s normalisation process during production
TX12 Analogue Load Cell Transmitter

The TX12 is a precise and reliable analogue load cell transmitter that integrates easily into process control and force measurement systems. It offers programmable analogue outputs and high-quality hardware to minimize long-term drifts. The eCal electronic calibration feature simplifies calibration for high-capacity tanks and silos.

  • Programmable analogue output: 4-20 mA, 0-20 mA, 0-10 V, or 0-5 V
  • High-resolution, matched, and normalized analogue output
  • Fast calibration feature similar to digital indicators
  • Two programmable cut-off outputs for control or alarm signals
Specifications
  • Analogue output: 4-20 mA, 0-20 mA, 0-10 V, or 0-5 V
  • 16-bit DAC with very low drift and high accuracy
  • Analogue output changes up to 60,000 steps
  • A/D conversion: 24-bit Delta-Sigma with integrated filters
  • Load cell signal range: -19 mV to +19 mV
  • Linearity: < 0.01%
  • Temperature drift: < 0.007% FSR/°C
  • Supports up to 4 load cells (350 Ω) or 12 load cells (1100 Ω)
  • Power supply: 12-28 VDC, max. 0.2 A
  • Operating temperature: -15°C to +55°C
  • Humidity: 85% RH max, non-condensing
  • Enclosure: Polyamide, DIN-rail mount, IP20
Setup & Communication
  • Front panel with 3 status LEDs and 2 rotary switches
  • RS-232C for programming from PC or PLC
  • Setup and adjustment software: xFace
See more

Catalog excerpts

Baykon TX12 Analogue Transmitters-1

TX12 Analogue Transmitter Precise and smart analogue load cell transmitter System Integration • 4-20 mA, 0-20 mA, 0-10 V or 0-5 V analogue outputs • Normalised, matched and high resolution analogue outputs • Calibration at PLC side with default adjustments • 2 relay contact outputs • Minimized long time drifts eCal - Electronic Calibration • Calibration without using test weights via RS-232C port • Provides big advantage for heavy capacity tank, silo and hopper scale calibration • High accuracy because of instrument’s normalisation process at the production Typical Applications • Tank and silo weighing • Compressive and tensile tests • Force measurement • Strength measurement • Process control applications • Dosing systems TX12 analog load cell transmitter is accurate and reliable instrument which is easily integrated into process control and force measurement systems. Analogue output is programmable to 4-20 mA, 0-20 mA, 0-10 V or 0-5 V. Its high quality analog and digital hardware minimizes long time zero and span drifts. Its high resolution, matched and normalized analogue output gives advantage calibration at PLC and changing the instrument without recalibration. eCal electronic calibration gives advantage easy calibration of the high capacity tanks and silos. Its additional fast calibration feature enables performing calibration similar to digital indicators. 2 cut off outputs of TX12 can be set via programming rotary switches on front of the instrument or via PC software to produc

 Open the catalog to page 1
Baykon TX12 Analogue Transmitters-2

Analogue Output Analogue output D/A conversion External resolution A/D Conversion Load cell signal range Minimum load cell signal range Linearity Temperature drift A/D conversion Internal resolution Weighing Calibration Electronic calibration 4 - 20 mA, 0 - 20 mA, 0 - 10 V or 0 - 5 V 16 bit very low drift and very high accurate DAC Analogue output changes up to 60 000 steps -19 mV to +19 mV < 1 mV < % 0.01 < 0.007 % FSR / ºC 24 bit Delta-Sigma ratiometric with integrated analogue and digital filters Up to 16 000 000 counts Performed with rotary switches on the front of instrument. eCal calibration...

 Open the catalog to page 2

All BAYKON Industrial Weighing Systems catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.