Overview: This document provides comprehensive technical specifications and operational guidelines for the DS series of three-phase synchronous motors manufactured by Baumüller Nürnberg GmbH. These motors are designed for high efficiency and power density, suitable for advanced mechanical engineering applications.
General Technical Data: The motors are available in configurations such as IP23 internally ventilated and IP54 surface-cooled or unventilated. They feature forced ventilation options, multiple connection types, and are largely maintenance-free. They operate efficiently in ambient temperatures up to 40°C and altitudes below 1000m, with correction factors for higher conditions.
Ratings Definition: Nominal power and torque ratings are provided for continuous operation, with adjustments for higher ambient temperatures and altitudes. Correction factors are detailed for these adjustments.
Winding Isolation and Temperature Rise: Motors are built with insulation class F, suitable for a winding temperature rise of 105K. Special insulation options are available for high humidity or corrosive environments.
Motor Data Explanation: Key parameters such as nominal power, torque, current, voltage, efficiency, and frequency are defined, explaining their significance in motor performance.
Type Key: A detailed breakdown of the motor type key is provided, explaining coding for features like UL approval, voltage, speed, cooling method, protection type, and frame size.
Technical Data: Specific technical data for various motor models are provided, including nominal speed, power, torque, current, voltage, efficiency, and weight. Maximum standstill torque values are listed for different motor types.
Additional Features: Information on bearings, shaft load, radial force diagrams, terminal marking, thermal sensors, noise intensity, vibration severity, fan data, brake assignment, and encoder options is included.
Commissioning and Maintenance: Guidelines for commissioning and maintaining the motors are provided to ensure optimal performance and longevity.
Temperature Monitoring: Motor temperature is monitored using a KTY 84-130 thermal sensor, providing resistance readings with a 2 mA current.
Noise and Vibration: Ventilated motors comply with EN 60034 noise standards, while unventilated motors have lower noise levels. Vibration severity is categorized into three classes with specific velocity limits.
Fan and Brake Specifications: Fans are connected via a terminal box with specified nominal currents. Brake types, torque, input power, and switching energy are detailed, including guidelines for using brakes as holding brakes.
Encoder and Resolver Details: Specifications for resolvers and encoders, including SINCOS and Heidenhain models, are provided with details on signal output and connection diagrams.
Motor Dimensions and Cables: Dimension drawings for various motor configurations are included. Motor cables are described with emphasis on flexibility, resistance to media, and EMC compliance.
Control Cable Specifications: Control cable pairs are organized as star-quads with specific color assignments. Detailed specifications for cable cross-sections, nominal currents, and cable diameters are provided.
Application Notes: Operating temperature range for cables is -20°C to +80°C. Cables should not touch the motor surface, and the minimum bending radius is 12 times the outer cable diameter.
Ordering Data: Detailed article numbers are provided for various lengths of encoder cables.
Contact Information: Contact details for Baumüller locations worldwide, including headquarters in Nürnberg, Germany, are listed.
See more

Catalog excerpts

Three phase synchronous motors DS 100-160-4

Three-phase synchronous motors of the DS series are permanently excited motors. Boasting a very high power density, very high efficiency and high response the motors are perfectly suitable for most sophisticated applications in mechanical engineering.This is additionally supported by a high overload capability. These durable, compact motors are also largely maintenance-free,which is an extra benefit to ensure most efficient operation. >

 Open the catalog to page 4
Three phase synchronous motors DS 100-160-6

Three-phase synchronous motors 100 - 160 > U > LMotor with UL approvalcULMotor with cUL approvalMains voltage / Motor voltage5400V / 360V XSpecial voltageNominal speede.g. 15 = 1500 min -1 Cooling methodRradially mounted external fanUunventilated TSuitable for pipe mounting WWater coolingType of protection23IP 23 54IP 54Length: K, M, L, BFrame size100...200Brakewithout brakeGwith brakeVersionFoot mountingFFlange mountingFFFoot֖ flange mountingMotor typeDSThree-phase synchronous motor Technical alterations reserved 403/03Three-phase synchronous motors DS100 160Baumּller Nrnberg GmbH >

 Open the catalog to page 6
Three phase synchronous motors DS 100-160-19

VibrationseveritySpeedFrame size > -1 100-132160 [ min ]V > eff [mm/s] N600- 1800 (normal)> 18001.82.8 R*600- 18000.711.12 (reduced)> 18001.121.8 S*600- 18000.450.71 (special)> 18000.711.12 The motors can be supplied in three vibration classes according to DIN ISO 5473. > Radial fanFrame sizeFan typeNom. current [A] with Y 100BFB 3980.33 132BFB 5190.8 160BFB 6351.4 >

 Open the catalog to page 19
Three phase synchronous motors DS 100-160-22

Three-phase synchronous motors 100 - 160 SINCOS SRS/SRM 50 (Stegmann) SRS 50 / SRM 50 Number of sine, cosine periods per revolution1024 Number of increments per revolution32768 Number of absolute resolved revolutions14096 Code type for the absolute valueBinary Output frequency of sine, cosine signals (kHz)0 ... 200 Error limits when evaluating 1024 signals, integral non-linearity(arc seconds)+/- 45 Non-linearity within a sine, cosine period; differential non-linearity (arc seconds)+/- 7 Working speed up to which the absolute position can beformed (1/min)6000 Maximum operating speed (1/min)12000...

 Open the catalog to page 22
Three phase synchronous motors DS 100-160-27

TypeShaftFlange B5Flange B 14 dltua > 1 b > 1 c > 1 e > 1 f > 1 g > 1 i > 1 s > 1 a > 1 b > 1 e > 1 f > 1 i > 2 s > 1 100 K421104512300230122654240110141771101302115M8IM B35 only 100 MIP54 in B5 only 100 L 100 B 132 K551105916400300163505312110182391301652115M10IM B35 only 132 M35025013300526011018IM B5; IM B35 132 L 132 B 160 K60140641840030020350531614018IM B35 only 160 M 160 L 160 B >

 Open the catalog to page 27
Three phase synchronous motors DS 100-160-28

100BFB 398124176246162145 132BFB 519175206306213163 160BFB 635215546336545189 Filter towards N-endView to D-end Dimension when fan at the top in [mm]MotorframesizeFan typeABCDE > Dimension when fan at the top in [mm]MotorframesizeFan typeFGHJ 100BFB 39821878311174 132BFB 51926592298205 Filter towards N-endView to D-end With frame size 100 filter towards non-drive end 160BFB 635310100458213 > Filter towards N-endView to D-endDimension when fan at the top in [mm]MotorframesizeFan typeKLMN 160BFB 63531092450256 When silencer on the non-drive end, it must be supported by the customer. >

 Open the catalog to page 28
Three phase synchronous motors DS 100-160-29

Three-phase synchronous motors 100 - 160 Encoder male and female connectors Female connector Male connector Technical alterations reserved Three-phase synchronous motors DS100- 16003/0327Baumller Nrnberg GmbH >

 Open the catalog to page 29
Three phase synchronous motors DS 100-160-30

Three-phase synchronous motors 100 - 160 > The motor cables are highly flexible trailing cables with overall shielding.They comply with the regulations VDE, UL and CSA.The brake is controlled via the brake connection (terminal box, brake), the thermal sensor is connected via the main connection. The cables are particularly suitable for the optimum use of cable racks thanks to their low cross-section, low weight and non-impeding surface.They can thus be efficiently used in trailing chains.The overall shielding with an optical coverage of more than 85% makes it an EMC uncritical cable. General...

 Open the catalog to page 30
Three phase synchronous motors DS 100-160-31

Three-phase synchronous motors 100 - 160 > 2 can be laid up to 100 m without additional filters, when larger cross-sections used, cable lengths up to 40 m are permissible.The terminal voltage at the motor must be < 1kV, however.If the terminal voltages exceed 1 kV, filters must be installed between converter and motor. Application notes > The cables can be operated within a temperature range from 20ְC to +80C. > The cables must not touch the motor surface. > 12 times outer cable diameter.Smaller bending radii are possible with reduced service life. Technical alterations reserved Three-phase synchronous...

 Open the catalog to page 31
Three phase synchronous motors DS 100-160-32

Three-phase synchronous motors 100 - 160 > General A fully preassembled encoder cable is used for all encoder systems.Motor connection is via a 12-pin round signal connector and converter connection via a 15-pin sub-D plug.The encoder cables are available as 'trailing' and 'non-trailing' cables.The trailing cable is suitable for use in trailing chains, for example.As opposed to the 'non-trailing' cable, the cable sheath consists of tougher PUR for use in environments with acids and bases (coolants) instead of PVC.Up to a length of 10 m, the cables are available in 1 m sections (1 m, 2 m, 10 m).From...

 Open the catalog to page 32
Three phase synchronous motors DS 100-160-34

Three-phase synchronous motors 100 - 160 > Please contact us for our commissioning and maintenance instructions for motor commissioning. Technical alterations reserved 3203/03Three-phase synchronous motors DS100 160Baumּller Nrnberg GmbH >

 Open the catalog to page 34
Three phase synchronous motors DS 100-160-35

The Netherlands Platinastraat 141 NL-2718 SR ZoetermeerTel +31(0)79-3614-290 Baumռller Benelux B.V. Colak Ismail Sok., No:31/1 Fax +31(0)79-3614-339 Օ TR-81070 Istanbul-SuadiyeTel +90 (0)216 372-2485 Turkey Fax +90 (0)216 372-7570 BAUM՜LLER MOTOR KONTROL SISTEM SAN. VE TIC. LTD. STI USA Baumueller Hartford Inc. 117 West Dudley Town Road USA-Bloomfield,CT 06002 > Darmstadt Baumռller Griesheim GmbH & Co. KG Motors Waldstrae 1 ߕ D-64347 GriesheimTel +49- (0)6155 8430-00 Baumller Nrnberg GmbH 켕 Fax +49- (0)6155 8430-20 Ostendstrae 80- 90 ߕ D-90482 NrnbergTel +49- (0)911-5432-0 Fax +49- (0)911-5432-130...

 Open the catalog to page 35

All Baumüller Nürnberg GmbH catalogs and technical brochures

  1. b maXX PCC04

    2  Pages

  2. Imagebroschüre

    16  Pages

  3. b maXX_2019

    48  Pages

  4. Automation

    48  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.