Three-phase synchronous motors of the DS series are permanently excited motors. Boasting a very high power density, very high efficiency and high response the motors are perfectly suitable for most sophisticated applications in mechanical engineering.This is additionally supported by a high overload capability. These durable, compact motors are also largely maintenance-free,which is an extra benefit to ensure most efficient operation. >
Open the catalog to page 4Three-phase synchronous motors 100 - 160 > U > LMotor with UL approvalcULMotor with cUL approvalMains voltage / Motor voltage5400V / 360V XSpecial voltageNominal speede.g. 15 = 1500 min -1 Cooling methodRradially mounted external fanUunventilated TSuitable for pipe mounting WWater coolingType of protection23IP 23 54IP 54Length: K, M, L, BFrame size100...200Brakewithout brakeGwith brakeVersionFoot mountingFFlange mountingFFFoot֖ flange mountingMotor typeDSThree-phase synchronous motor Technical alterations reserved 403/03Three-phase synchronous motors DS100 160Baumּller Nrnberg GmbH >
Open the catalog to page 6VibrationseveritySpeedFrame size > -1 100-132160 [ min ]V > eff [mm/s] N600- 1800 (normal)> 18001.82.8 R*600- 18000.711.12 (reduced)> 18001.121.8 S*600- 18000.450.71 (special)> 18000.711.12 The motors can be supplied in three vibration classes according to DIN ISO 5473. > Radial fanFrame sizeFan typeNom. current [A] with Y 100BFB 3980.33 132BFB 5190.8 160BFB 6351.4 >
Open the catalog to page 19Three-phase synchronous motors 100 - 160 SINCOS SRS/SRM 50 (Stegmann) SRS 50 / SRM 50 Number of sine, cosine periods per revolution1024 Number of increments per revolution32768 Number of absolute resolved revolutions14096 Code type for the absolute valueBinary Output frequency of sine, cosine signals (kHz)0 ... 200 Error limits when evaluating 1024 signals, integral non-linearity(arc seconds)+/- 45 Non-linearity within a sine, cosine period; differential non-linearity (arc seconds)+/- 7 Working speed up to which the absolute position can beformed (1/min)6000 Maximum operating speed...
Open the catalog to page 22TypeShaftFlange B5Flange B 14 dltua > 1 b > 1 c > 1 e > 1 f > 1 g > 1 i > 1 s > 1 a > 1 b > 1 e > 1 f > 1 i > 2 s > 1 100 K421104512300230122654240110141771101302115M8IM B35 only 100 MIP54 in B5 only 100 L 100 B 132 K551105916400300163505312110182391301652115M10IM B35 only 132 M35025013300526011018IM B5; IM B35 132 L 132 B 160 K60140641840030020350531614018IM B35 only 160 M 160 L 160 B >
Open the catalog to page 27100BFB 398124176246162145 132BFB 519175206306213163 160BFB 635215546336545189 Filter towards N-endView to D-end Dimension when fan at the top in [mm]MotorframesizeFan typeABCDE > Dimension when fan at the top in [mm]MotorframesizeFan typeFGHJ 100BFB 39821878311174 132BFB 51926592298205 Filter towards N-endView to D-end With frame size 100 filter towards non-drive end 160BFB 635310100458213 > Filter towards N-endView to D-endDimension when fan at the top in [mm]MotorframesizeFan typeKLMN 160BFB 63531092450256 When silencer on the non-drive end, it must be supported by the customer. >
Open the catalog to page 28Three-phase synchronous motors 100 - 160 Encoder male and female connectors Female connector Male connector Technical alterations reserved Three-phase synchronous motors DS100- 16003/0327Baumller Nrnberg GmbH >
Open the catalog to page 29Three-phase synchronous motors 100 - 160 > The motor cables are highly flexible trailing cables with overall shielding.They comply with the regulations VDE, UL and CSA.The brake is controlled via the brake connection (terminal box, brake), the thermal sensor is connected via the main connection. The cables are particularly suitable for the optimum use of cable racks thanks to their low cross-section, low weight and non-impeding surface.They can thus be efficiently used in trailing chains.The overall shielding with an optical coverage of more than 85% makes it an EMC uncritical cable....
Open the catalog to page 30Three-phase synchronous motors 100 - 160 > 2 can be laid up to 100 m without additional filters, when larger cross-sections used, cable lengths up to 40 m are permissible.The terminal voltage at the motor must be < 1kV, however.If the terminal voltages exceed 1 kV, filters must be installed between converter and motor. Application notes > The cables can be operated within a temperature range from 20ְC to +80C. > The cables must not touch the motor surface. > 12 times outer cable diameter.Smaller bending radii are possible with reduced service life. Technical alterations reserved Three-phase...
Open the catalog to page 31Three-phase synchronous motors 100 - 160 > General A fully preassembled encoder cable is used for all encoder systems.Motor connection is via a 12-pin round signal connector and converter connection via a 15-pin sub-D plug.The encoder cables are available as 'trailing' and 'non-trailing' cables.The trailing cable is suitable for use in trailing chains, for example.As opposed to the 'non-trailing' cable, the cable sheath consists of tougher PUR for use in environments with acids and bases (coolants) instead of PVC.Up to a length of 10 m, the cables are available in 1 m sections (1 m, 2 m, 10...
Open the catalog to page 32Three-phase synchronous motors 100 - 160 > Please contact us for our commissioning and maintenance instructions for motor commissioning. Technical alterations reserved 3203/03Three-phase synchronous motors DS100 160Baumּller Nrnberg GmbH >
Open the catalog to page 34The Netherlands Platinastraat 141 NL-2718 SR ZoetermeerTel +31(0)79-3614-290 Baumռller Benelux B.V. Colak Ismail Sok., No:31/1 Fax +31(0)79-3614-339 Օ TR-81070 Istanbul-SuadiyeTel +90 (0)216 372-2485 Turkey Fax +90 (0)216 372-7570 BAUM՜LLER MOTOR KONTROL SISTEM SAN. VE TIC. LTD. STI USA Baumueller Hartford Inc. 117 West Dudley Town Road USA-Bloomfield,CT 06002 > Darmstadt Baumռller Griesheim GmbH & Co. KG Motors Waldstrae 1 ߕ D-64347 GriesheimTel +49- (0)6155 8430-00 Baumller Nrnberg GmbH 켕 Fax +49- (0)6155 8430-20 Ostendstrae 80- 90 ߕ D-90482 NrnbergTel +49- (0)911-5432-0 Fax +49-...
Open the catalog to page 35All Baumüller Nürnberg GmbH catalogs and technical brochures
-
Baumüller Marine Solutions
20 Pages
-
b maXX PCC04
2 Pages
-
Imagebroschüre
16 Pages
-
b maXX
48 Pages
-
Automation
48 Pages
Archived catalogs
-
Mobile Drives
24 Pages
-
Volume reduced
2 Pages
-
BAS-Blech
1 Pages
-
Ubiquity
6 Pages
-
Servo pumps
2 Pages
-
3- and multi-axis handling
8 Pages
-
b maXX
44 Pages
-
Disc Motors
20 Pages
-
Direct Drives
32 Pages
-
Motors
32 Pages
-
Baumüller at a glance
8 Pages
-
Safety Lifecycle Navigator
64 Pages