
Catalog excerpts

Process Analyzer Viscosity Process Analyzer VISC-4 Credible Solutions for the Oil and Gas Industry
Open the catalog to page 1
Process Analyzer Viscosity Process Analyzer VISC-4 To remain competitive, today’s refiners must employ all optimization and product control techniques available. The use of online physical property analyzers is one of the key features to reach those objectives because they measure important quality properties in the process directly. All fluids that fulfil the conditions of Newton’s friction law are referred to as Newtonian fluids. Their viscosity is a material constant, which is only dependent on pressure and temperature. The viscosity for incompressible and Newtonian fluids can be derived...
Open the catalog to page 2
Special Features: Direct and continuous measurement of kinematic viscosity therefore direct comparison with laboratory results without any need for conversion Integral measurement of the density therefore calculation and display of the dynamic viscosity Minimized maintenance requirements due to temperature control and insulating system without oil bath/pumps Compliance of the temperature stability (±0.02 K) as defined in standard ASTM D445 Necessity of Hagenbach correction is eliminated Multi-stream capability Automatic rinsing and draining option Integrated failure...
Open the catalog to page 3
Viscosity Process Analyzer VISC-4 EXPLOSION PROTECTION TECHNICAL DATA Measuring cycle Product streams Nominal voltage Maximum power Protection class Ambient conditions Ambient temperature Ambient humidity continuously analyzing kinematic viscosity, compliant with: (additional hardware required) other ratings on request operation 5 to 80 % relative humidity, storage 5 to 85 % relative humidity, max. viscosity = end of measuring range (technical clarification required) Signal outputs and inputs Analog outputs Digital outputs Digital inputs Electrical data of signal Analog outputs Digital...
Open the catalog to page 4All BARTEC catalogs and technical brochures
-
HCDT
3 Pages
-
HYGROPHIL F
4 Pages
-
VI_4
4 Pages
-
PPA
4 Pages
-
MGA-nano
4 Pages
-
CFPP
5 Pages
-
FPA
1 Pages
-
364923
1 Pages
-
127309
2 Pages
-
R2810
2 Pages
-
R300/301/302
8 Pages
-
R2610
4 Pages
-
R310/11/12/20
9 Pages
-
R271
2 Pages
-
309267_1
3 Pages
-
VISC_4
4 Pages
-
RVP_4
4 Pages
-
DPA
2 Pages
-
CPA_4
4 Pages
-
Switchgear and control gear
4 Pages
-
A200865_7
2 Pages
-
A200865_1
6 Pages
-
A200663_4
1 Pages
-
A240847_1
2 Pages
-
A200863
2 Pages
-
A280071
1 Pages
-
A200639_1E
4 Pages
-
A200639
2 Pages
-
321815_1E
3 Pages
-
E246952_1E
2 Pages
-
E301445_E
1 Pages
-
E246821_1E
2 Pages
-
E246957_1E
4 Pages
-
246903_1E
4 Pages
-
E246904_2E
1 Pages