FPA
1Pages

{{requestButtons}}

Catalog excerpts

FPA - 1

Utilities Instrument air Consumption Purge: 8 Nm3/h while purging (~12 min) Operation: approx. 1 Nm3/h Pressure at inlet 2 to 7 bar (29 to 101.5 psi) Qualityhumidity class 2 or better acc. to ISO 8573.1 Coolant depends on flash point temperature Consumption sample as coolant: 30 to 60 l/h or plant cooling water: 10 to 40 l/h Temperature +5 to +40 °C (+41 to +104 °F) Certification TR CU available Other approvals and certificates, see www.bartec.de Technical data Technology continuous measurement using catalytic combustion Method correlates with: Repeatability s DIN EN/ASTM e.g. kerosene typ. 0.1 °C (approx. 0.2 °F) Reproducibility s DIN EN/ASTM Measuring cyclecontinuous Product streams 2 x sample, 1 x validation (additional hardware required) Signal outputs and inputs Analog outputs flash point temperature (others on request) Digital outputsAlarm, Ready/Valid Digital inputs Stream Selection, Validation Request, Reset Electrical data of signal outputs and inputs Analog outputs max. 8 (4 to 20 mA; 1000 Q) active isolated on request Analog inputs4 to 20 mA; 160 Q Digital outputs 24 V DC; max. 0.5 A Digital inputs high: 15 to 28 V DC; low: 0 to 4 V DC Auxiliary power 24 V DC; max. 0.8 A supply output Control unit_ Central control unit Industrial PC Operating system Windows Embedded Standard 7® Control software PACS Electrical data Nominal voltage 230 V AC ± 10 %, 1 phase; 50 Hz; other ratings on request Maximum approx. 500 W power consumption Protection class IP 54 (NEMA 13) Ambient temperature operation: +5 to +40 °C (+41 to +104 °F) storage: 0 to +60 °C (+32 to +140 °F) Ambient humidity operation: 5 to 80 % relative humidity, non-corrosive storage: 5 to 85 % relative humidity, non-corrosive Sample Quality filtered 50 gm, free of suspended water, bubble-free, sulfur < 2000 ppm, free of heavy metals, free of phosphate (s 37 cSt at inlet temperature) Consumption approx. 2 to 3 l/h (at sample inlet) Temperature at inlet min. 15 °C below Flash Point, max. +80 °C, temperature change maximum 1 K/min, For cooling with product: max. +40 °C For using an inductive ring-type initiator ("min. contact") on the flow meter: max. +60 °C User interfaces Display TFT display with touch function 1024 x 768 pixel Keyboard virtual keyboard, controlled via TFT display with touch function Connections Tube fittings Swagelok® 6 mm/12 mm/18 mm other fittings on request Vent/Drain open to atmosphere Dimensions (W x H x D) approx. 1140 x 2000 x 710 mm Space requirements right: 200 mm/left: 200 mm Optional interfaces_ Analog outputs on request MODBUS interface MODBUS/RTU via RS485 or RS422 or FOC is, MODBUS/TCP via FOC is Remote access via Ethernet (VDSL or FOC is) Important notice FPA-4 is subject to continuous product improvement, specifications are preliminary and may be subject to change without notice. If your technical data do not comply with existing data, please contact us for technical clarification. BARTEI BENKE Phone: +49 40 72703-0 sales@bartec-benke.de www.bartec-benke.de

Open the catalog to page 1

All BARTEC catalogs and technical brochures

  1. HCDT

    3 Pages

  2. HYGROPHIL F

    4 Pages

  3. VI_4

    4 Pages

  4. PPA

    4 Pages

  5. MGA-nano

    4 Pages

  6. CFPP

    5 Pages

  7. A/xx

    4 Pages

  8. 364923

    1 Pages

  9. 127309

    2 Pages

  10. R2810

    2 Pages

  11. R300/301/302

    8 Pages

  12. R2610

    4 Pages

  13. R271

    2 Pages

  14. 309267_1

    3 Pages

  15. VISC_4

    4 Pages

  16. RVP_4

    4 Pages

  17. DPA

    2 Pages

  18. CPA_4

    4 Pages

  19. A200865_7

    2 Pages

  20. A200865_1

    6 Pages

  21. A200663_4

    1 Pages

  22. A240847_1

    2 Pages

  23. A200863

    2 Pages

  24. A280071

    1 Pages

  25. A200639_1E

    4 Pages

  26. A200639

    2 Pages

  27. 321815_1E

    3 Pages

  28. E246952_1E

    2 Pages

  29. E301445_E

    1 Pages

  30. E246821_1E

    2 Pages

  31. E246957_1E

    4 Pages

  32. 246903_1E

    4 Pages

  33. E246904_2E