1. Catalogs
  2. BARTEC
  3. E246957_1E

E246957_1E

E246957_1E

E246957_1E

Product catalog summary
Overview: The document provides technical specifications and features of the HSB system heating cable, a self-limiting parallel heating cable designed for various industrial applications, including use in explosive atmospheres.
Specifications:
  • Conductors: Stranded copper busbars, 1.2 mm2, nickel plated.
  • Heating Element: Self-limiting synthetic polymer.
  • Insulation: Fluoropolymer electrical insulation jacket.
  • Braiding: Tinned copper braiding.
  • Protective Jacket: Fluoropolymer.
Features:
  • Steam cleaning capability.
  • Self-limiting to prevent overheating.
  • Usable in explosive atmospheres without a temperature limiter.
  • Flexible installation due to parallel circuit configuration.
  • Corrosion-proof and resistant to chemical attacks.
Description: The heating cable features a temperature-dependent resistive element that regulates heat output based on ambient temperature, reducing heat output as temperature rises. This self-limiting property eliminates the need for a temperature limiter, even in hazardous zones. The cable can be cut to any length, simplifying installation and maintenance.
Applications: Suitable for environments with high humidity or exposure to organic chemicals and where high mechanical requirements are needed.
Technical Data:
  • Nominal Voltage: AC 208 V to 254 V, AC 110 V to 120 V.
  • Permissible Ambient Temperature: Cut-in at +120 °C, Cut-off at +190 °C.
  • Minimum Installation and Storage Temperature: -60 °C.
Explosion Protection: Certified for use in explosive atmospheres with various protection types and certifications, including KEMA and IECEx.
Performance: Heat output varies with pipe temperature and is specified for different models (HSB 10, 15, 25, 30, 45, 60) at 230 V and 120 V.
Dimensions: With protective braid and jacket, dimensions are 10.2 x 4.8 mm, with a minimum bending radius of 25 mm.
Selection Chart: Provides order numbers for different HSB models based on heating output and voltage requirements.
See more

Catalog excerpts

E246957_1E-1

HSB System Heating cable HSB parallel heating cable HSB stranded copper busbars, 1.2 mm2, nickel plated 2. Self-limiting synthetic polymer heating element 3. Fluoropolymer electrical insulation jacket 4. Tinned copper braiding 5. Protective jacket of fluoropolymer Steam cleaning possible Can be used in explosive atmospheres without temperature limiter Can be cut to length at random thanks to its parallel circuit configuration Simple installation thanks to its high flexibility and favourable dimensions Easy on-site cutting and terminating, Corrosion-proof and resistant to chemical attack thanks to its protective outer jacket A temperature-dependant resistive element be- tween two parallel copper conductors regulates and limits the heat output of the heating cable. This output regulation is carried out automati- cally along the entire length of the heating cable according to the prevailing ambient temperature. As the ambient temperature rises, the heat out- put of the cable is reduced. This self-limiting property prevents overheating even when the cable are overlapped. A temperature limiter is not required (not even in explosion hazard zones). Thanks to the parallel power supply the heating cable can be cut to any required length. This fea- ture considerably simplifies project planning and installation. The heating cable is cut and termi- nated in accordance with the local requirements directly on the construction site. In cases where the cable may become damaged, it is not neces- sary to replace the whole circuit but only the affected part. BARTEC-HEAT HSB is available in different ver- sions and with different power outputs.

 Open the catalog to page 1
E246957_1E-2

HSB System Heating cable HSB HSB with fluoropolymer protective jacket ■ if the heating cable is exposed to high levels of humidity organic chemicals such as ■ where the cable must meet high mechanical requirements. Heat output on insulated steel pipes at 230 V under nominal conditions. Verification Certification System Verification Certification Components Max. resistance of protective braid with protective braid and protective outer jacket of fluoropolymer

 Open the catalog to page 2
E246957_1E-3

HSB System Heating cable HSB Permissible ambient temperature Cut-in heating cable +120 °C Cut-off heating cable +190 °C Minimum installation temperature -60 °C Minimum storage temperature -60 °C Minimum cut-in temperature -60 °C

 Open the catalog to page 3
E246957_1E-4

HSB System Heating cable HSB

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.