A200639_1E-1

Cable entries Cable entries Features Description æ Ex e terminal boxes are dispensed with Flameproof Ex d cable entries are elements which allow electrical cables to be introduced into an Ex d enclosure, without danger of explosion. The additional Ex e terminal housing is not required. A main distribution box may by used or the connections can be made outside the Exzone. The cable entry consists of a threaded metal sleeve, in which a sheathed cable is anchored and encapsulated. The individual cores are then connected directly inside the flameproof enclosure. The length of cores and cables are customer-tailored. All cables come with standard green-yellow earth leads. The length of engaged thread between the sleeve and the flameproof “d“ enclosure must comply with DIN EN 60079-0: 2006 and DIN EN 60079-1. The cable entry is normally inserted from the inside of the flameproof enclosure. A special version can be supplied for insertion from the outside, provided that removal is possible with a special tool only. After installation, the cable entry must be protected against turning and loosening, corresponding recommendations can be found under accessories. æ Suitable for cables with 1 to max. 25 cores æ Sleeves from M16 x 1.5 to M48 x 1.5 æ Compact, space-saving design æ The cores are connected directly to the electrical load at the Ex d side, intermediate terminal positions are dispensed with æ Rated insulation voltage of up to 1000 V for small dimensions æ For Ex i circuits with blue cables 03-0330-0183/A-07/10-BCS-200639/1 æ Permanent heat resistance up to +110 °C All line bushings have been certified by the Federal Physical-Technical Institute in accordance with the European standards DIN EN 60079-0 and DIN EN 60079-1 concerning electrical operating equipment for hazardous areas for above-ground (II) and underground (I) according to ATEX. When the 94/9/EC guideline comes into force on 01/07/2003, explosion protected operating equipment must be properly Installed in accordance with DIN EN 60079-14. Among other things, section 10.4.2 requires that cast, pressure-proof cable insertions according to DIN EN 60079-1: 2007 are used for operating equipment with an internal ignition source for the explosion sub-group IIC and operating equipment with an enclosure volume greater than 2 dm3 in Zone 1. BARTEC offers a wide range of products with EC model test certification. 170 200639_1_2.pmd 2 12.11.2010, 11:52

 Open the catalog to page 1
A200639_1E-2

Cable entries Explosion protection Version Standard Cable entry screwable EN 60079-0 and EN 60079-1 Ex protection type II 2G Ex d IIC T6/T4 Certification PTB 97 ATEX 1079 X Cable entry pluggable EN 60079-0 and EN 60079-1 II 2G Ex d IIC T6/T4 PTB 03 ATEX 1197 U 1 Electrical data Nominal voltage Cable Cross section Threaded sleeve in mm² 300 V/500 V H05RR-F H05RN-F 0.75 to 2.5 M16 x 1.5 to M 48 x 1.5 +60 °C 300 V/500 V H05GG-F, Radox 125 Radox 155 0.75 to 6 M16 x 1.5 to M 48 x 1.5 +110 °C 300 V/500 V Ölflex, H05VV-F 0.75 to 2.5 M16 x 1.5 to M 48 x 1.5 +70 °C 0.5 to 2.5 M16 x 1.5 to M 48 x 1.5 +70...

 Open the catalog to page 2
A200639_1E-3

Cable entries 300/500 V Selection chart cable H05RN-F or H05RR-F Number of cores Conductor cross section mm2 Current carrying capacity (A) in continuous operation (rel. values) 1) Maximum on-site temperature +60 °C Thread size Order no. Please indicate core and cable length in plain text 3 5 0.75 0.75 9.5 A M16 x 1.5 M24 x 1.5 07-9204-F03D 07-9204-F052 3 5 1.5 1.5 15 A M24 x 1.5 M24 x 1.5 07-9204-H032 07-9204-H052 3 5 2.5 2.5 20 A M24 x 1.5 M36 x 1.5 07-9204-J032 07-9204-J054 m6 Dimensions for 300/500, 450/750 V, 1000 V in mm m4 m7 m3 m5 Boss side m2 Sleeve side m1 m1 m6 m4 m7 m2 m3 M16 x 1.5...

 Open the catalog to page 3
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.